One Africa-One Market - Your Borderless B2B Sourcing Portal

Become a Merchant

Welcome To Zandaux

  • Vendor login
  • Track Your Order
  • Support
Sort by:
YMVK KEMA APPROVED PVC POWER CABLE YMVK KEMA APPROVED PVC POWER CABLE
YMVK KEMA APPROVED PVC POWER CABLE
Availability: In Stock
  • CONDUCTOR:  Plain Copper


    INSULATION:  XLPE                                   OUTERSHEATH: PVC


    OUTERSHEATH COLOUR: Grey               RATED VOLTAGE: 0.6/1kV


    CORE IDENTIFICATION: 

    2 core: Brown and Blue

    3 core: Brown, Blue and Green / Yellow

    4 core: Black, Grey, Brown and Green / Yellow

    5 core: Black, Blue, Brown, Grey and Green / Yellow

    Optional: 4 core - Black, Brown, Blue and Green / Yellow)


    MINIMUM BENDING RADIUS: 10 x overall diameter


    OPERATING TEMPERATURE: 

    Maximum 90°C, minimum bending 0°C / Short circuit temperature 250°C


    STANDARDS: HD 604 Part 4 Section D







    Batt Part No.

    Core

    Size

    Colour/Reference

    16592

    2

    1.5

    Grey

    16698

    2

    2.5

    Grey

    16699

    3

    1.5

    Grey

    16700

    3

    2.5

    Grey

    16487

    3

    4

    Grey

    16884

    3

    6

    Grey

    16917

    3

    10

    Grey

    16918

    3

    16

    Grey

    16701

    4

    1.5

    Grey

    16147

    4

    2.5

    Grey

    16703

    4

    4

    Grey

    16704

    4

    6

    Grey

    16705

    4

    10

    Grey

    16787

    4

    16

    Grey

    16907

    4

    35

    Grey

    16909

    4

    50

    Grey

    16024

    4

    120

    Grey

    16706

    5

    1.5

    Grey

    16271

    5

    2.5

    Grey

    16707

    5

    4

    Grey

    16272

    5

    6

    Grey

    16932

    5

    10

    Grey

    16941

    5

    16

    Grey

    16970

    7

    1.5

    Grey

    16971

    7

    2.5

    Grey

    16973

    12

    1.5

    Grey

    16974

    12

    2.5

    Grey

    16978

    24

    1.5

    Grey

    16979

    30

    1.5

    Grey









    BATT Part No

    No. of Cores

    Nominal cross sectional area of conductor (mm2)

    Radial thickness of insulation (mm)

    Nominal thickness of oversheath (mm)

    Approx overall diameter (mm)

    Weight

    16592

    2

    1.5

    0.70

    1.4

    9.3

    121

    16698

    2

    2.5

    0.70

    1.4

    10.1

    151

    16699

    3

    1.5

    0.70

    1.4

    9.4

    130

    16700

    3

    2.5

    0.70

    1.4

    10.3

    170

    16487

    3

    4

    0.70

    1.4

    11.2

    227

    16884

    3

    6

    0.70

    1.4

    12.6

    306

    16917

    3

    10

    0.70

    1.4

    14.6

    461

    16918

    3

    16

    0.70

    1.5

    17.6

    685

    16701

    4

    1.5

    0.70

    1.4

    10.2

    157

    16147

    4

    2.5

    0.70

    1.4

    11.1

    205

    16703

    4

    4

    0.70

    1.4

    12.2

    280

    16704

    4

    6

    0.70

    1.4

    13.7

    380

    16705

    4

    10

    0.70

    1.5

    15.8

    573

    16787

    4

    16

    0.70

    1.5

    19.1

    855

    16907

    4

    35

    0.90

    1.8

    26.1

    1756

    16909

    4

    50

    1.00

    1.9

    29.9

    2348

    16024

    4

    120

    1.20

    2.3

    44.2

    5618

    16706

    5

    1.5

    0.70

    1.4

    11.5

    199

    16271

    5

    2.5

    0.70

    1.4

    12.6

    262

    16707

    5

    4

    0.70

    1.4

    13.8

    357

    16272

    5

    6

    0.70

    1.4

    15.1

    468

    16932

    5

    10

    0.70

    1.5

    18.4

    744

    16941

    5

    16

    0.70

    1.6

    21.4

    1075

    16970

    7

    1.5

    0.70

    1.8

    12.5

     

    16971

    7

    2.5

    0.70

    1.8

    13.7

     

    16973

    12

    1.5

    0.70

    1.8

    15.8

     

    16974

    12

    2.5

    0.70

    1.8

    17.5

     

    16978

    24

    1.5

    0.70

    1.8

    24.6

     

    16979

    30

    1.5

    0.70

    1.8

    22.1

     


    • ELECTRICAL CHARACTERISTICS

    Nominal cross sectional area (mm2)

    Current carrying capacity (In Ground)

    Current carrying capacity (In Air)

    Max conductor DC resistance at 20°C (ohm/km)

    1.5

    30

    24

    12.1

    2.5

    24

    32

    7.41

    4

    52

    42

    4.61

    6

    64

    53

    3.08

    10

    86

    73

    1.83

    16

    11

    93

    1.15

    35

    173

    160

    0.524

    50

    205

    195

    0.387

    120

    390

    407

    0.124



  • New
YMVK SS KEMA APPROVED FLEXIBLE PVC POWER CABLE YMVK SS KEMA APPROVED FLEXIBLE PVC POWER CABLE
YMVK SS KEMA APPROVED FLEXIBLE PVC POWER CABLE
Availability: In Stock
  • ONDUCTOR: Plain Copper                       STRANDING: Class 5


    INSULATION: XLPE                                 BEDDING: PVC


    OUTERSHEATH: PVC                              OUTERSHEATH COLOUR: Grey


    RATED VOLTAGE: 0.6/1kV


    CORE IDENTIFICATION:

    Single core: Black

    2 core - Brown and Blue

    3 core - Brown, Blue and Green / Yellow

    4 core - Black, Grey, Brown and Green / Yellow

    5 core -Black, Blue, Brown, Grey and Green / Yellow

    Optional: 4 core - Black, Brown, Blue and Green / Yellow


    MINIMUM BENDING RADIUS: 5 x overall diameter


    OPERATING TEMPERATURE: Maximum 90°C, minimum bending 0°C


    STANDARDS: HD 604 Part 4 Section D







    Batt Part No.

    Core

    Size

    Colour/Reference

    16983

    1

    95

    Grey

    16980

    1

    240

    Grey

    16430

    4

    25

    Grey

    16814

    4

    70

    Grey

    16037

    4

    95

    Grey

    16285

    4

    120

    Grey

    16290

    4

    240

    Grey

    16878

    5

    25

    Grey

    16962

    5

    50

    Grey

    16861

    5

    70

    Grey

    16862

    5

    95

    Grey

    16035

    5

    120

    Grey








    BATT Part No

    No of cores

    Nominal cross sectional area of conductor mm2

    Approx overall diameter

    Weight

    Current ratings amps (open air 30°C)

    Current ratings amps (Buried 20°C)

    16983

    1

    95

    17.9

    970

    328

    211

    16980

    1

    240

    27.4

    2449

    607

    351

    16430

    4

    25

    24.1

    1340

    127

    101

    16814

    4

    70

    36.3

    3307

    246

    178

    16037

    4

    95

    41.4

    4440

    298

    211

    16285

    4

    120

    46.6

    5680

    346

    240

    16290

    4

    240

    64.3

    11365

    538

    351

    16878

    5

    25

    26.1

    1639

    127

    101

    16962

    5

    50

    34.5

    2915

    192

    144

    16861

    5

    70

    39.5

    4067

    246

    178

    16862

    5

    95

    46.8

    5623

    398

    211

    16035

    5

    120

    51

    7042

    346

    240



  • New
YMZ1K KEMA APPROVED LSZH POWER CABLE YMZ1K KEMA APPROVED LSZH POWER CABLE
YMZ1K KEMA APPROVED LSZH POWER CABLE
Availability: In Stock
  • CONDUCTOR:   Plain Copper                    STRANDING:   Class 1


    INSULATION: XLPE                                   OUTERSHEATH: LSZH


    OUTERSHEATH COLOUR: Grey              RATED VOLTAGE: 0.6/1kV


    CORE IDENTIFICATION: 

    3 core - Blue, Brown, Green/Yellow

    4 core - Brown, Black, Grey, Green/Yellow

    5 core - Blue, Brown, Black, Grey, Green/Yellow


    MINIMUM BENDING RADIUS: 10 x overall diameter


    OPERATING TEMPERATURE:  Maximum Operating: 90°C


    STANDARDS: HD-604-5-C KEMA K42C-1-5






    Batt Part No.

    Core

    Size

    Colour/Reference

    16662

    3

    1.5

    Grey

    16673

    3

    2.5

    Grey

    16679

    4

    1.5

    Grey

    16681

    4

    2.5

    Grey

    16684

    5

    1.5

    Grey

    16695

    5

    2.5

    Grey







    BATT Part No

    No. of cores

    Nominal cross sectional area of conductor (mm2)

    Radial thickness of insulation (mm)

    Nominal thickness of oversheath (mm)

    Approx overall diameter (mm)

    Weight

    16662

    3

    1.5

    0.70

    1.8

    11.0

    170

    16673

    3

    2.5

    0.70

    1.8

    11.8

    211

    16679

    4

    1.5

    0.70

    1.8

    11.7

    198

    16681

    4

    2.5

    0.70

    1.8

    12.6

    249

    16684

    5

    1.5

    0.70

    1.8

    12.5

    230

    16695

    5

    2.5

    0.70

    1.8

    13.5

    292


    • ELECTRICAL CHARACTERISTICS

    Nominal cross sectional area (mm2)

    Current carrying capacity (In Ground)

    Current carrying capacity (In Air)

    Maximum conductor DC resistance at 20°C (ohm/km)

    1.5

    30

    24

    12.1

    2.5

    24

    32

    7.41



  • New
YMZ1K-SS KEMA APPROVED FLEXIBLE LSZH POWER CABLE YMZ1K-SS KEMA APPROVED FLEXIBLE LSZH POWER CABLE
YMZ1K-SS KEMA APPROVED FLEXIBLE LSZH POWER CABLE
Availability: In Stock
  • CONDUCTOR: Plain Copper                   STRANDING: Class 5


    INSULATION: XLPE                                 OUTERSHEATH: LSZH


    OUTERSHEATH COLOUR: Grey             RATED VOLTAGE: 0.6/1kV


    CORE IDENTIFICATION

    1 core - Black

    4 core - Brown, Black, Grey, Green/Yellow

    5 core - Black, Brown, Blue, Grey, Green/Yellow


    MINIMUM BENDING RADIUS:        12 x overall diameter


    OPERATING TEMPERATURE:   Max. operating temp: 90ᴼC


    STANDARDS:     HD-604-5-C KEMA K42C-1-5




    Batt Part No.

    Core

    Size

    Colour/Reference

    16739

    1

    120

    Grey

    16730

    4

    95

    Grey

    16728

    4

    150

    Grey

    16713

    4

    185

    Grey

    16702

    5

    25

    Grey

    16640

    5

    35

    Grey









    BATT Part No

    No of Cores

    Nominal cross sectional area of conductor (mm2)

    Nominal thickness of insulation (mm)

    Nominal thickness of oversheath (mm)

    Approx overall diameter (mm)

    Weight (kg/km)

    16739

    1

    120

    1.20

    1.5

    19.4

    1178

    16730

    4

    95

    1.10

    2.1

    42.5

    4490

    16728

    4

    150

    1.4

    2.4

    53.3

    6988

    16713

    4

    185

    1.6

    2.6

    61.2

    8753

    16702

    5

    25

    0.90

    1.8

    28.7

    1686

    16640

    5

    35

    0.90

    1.8

    31.2

    2216



    • ELECTRICAL CHARACTERISTICS
      Single Core

    Nominal cross sectional area (mm2)

    Current carrying capacity In Conduit (Flat Formation)

    Current carrying capacity In Conduit (Trefoil Formation)

    Current carrying capacity In Air (Flat Formation)

    Current carrying capacity In Air (Trefoil Formation)

    Max conductor resistance at 20°C (Ω/km)

    120

    404

    341

    457

    370

    0.153


    • Multi Core

    Nominal cross sectional area (mm2)

    Current carrying capacity (In Ground)

    Current carrying capacity (In Air)

    Max conductor resistance at 20°C (Ω/km)

    25

    139

    126

    7.41

    35

    168

    155

    4.61

    95

    294

    296

    0.193

    150

    378

    395

    0.124

    185

    428

    455

    0.0991



  • New
33KV ALUMINIUM WINDFARM CABLE MDPE BS7870-4.10 33KV ALUMINIUM WINDFARM CABLE MDPE BS7870-4.10
33KV ALUMINIUM WINDFARM CABLE MDPE BS7870-4.10
Availability: In Stock
  • CONDUCTOR:   Aluminium               STRANDING:    Class 2


    INSULATION:    XLPE                        METALLIC SCREEN:  Copper Wire Screen


    OUTERSHEATH:        MDPE              OUTERSHEATH COLOUR:      Black


    RATED VOLTAGE:     19/33kV           MINIMUM BENDING RADIUS:       20 x Overall Diameter


    STANDARDS:        BS7870-4.10



    Batt Part No.

    Core

    Size

    Colour/Reference

    56719

    1

    70

    Black

    56751

    1

    95

    Black

    56720

    1

    120

    Black

    56721

    1

    150

    Black

    56698

    1

    185

    Black

    56722

    1

    240

    Black

    56699

    1

    300

    Black

    56723

    1

    400

    Black

    56724

    1

    500

    Black

    56725

    1

    630

    Black









    Nominal Cross Sectional Area of Conductor (mm)

    Weight (kg/km)

    Max. DC Resistance at 20o C (ohm/km)

    Max. AC resistance at 90o C (ohm/km)

    70

    1240

    0.443

    0.5682

    95

    1360

    0.32

    0.4106

    120

    1500

    0.253

    0.328

    150

    1615

    0.206

    0.2646

    185

    1770

    0.164

    0.2109

    240

    2010

    0.125

    0.1611

    300

    2350

    0.1

    0.132

    400

    2640

    0.0778

    0.1013

    500

    3000

    0.0605

    0.081

    630

    3540

    0.0469

    0.064


    •  

    BATT Part No

    Nominal cross sectional area of conductor (sqmm)

    Nominal Insulation Thickness (mm)

    Overall Diameter (mm)

    56719

    70

    8

    35.5

    56751

    95

    8

    37.2

    56720

    120

    8

    38

    56721

    150

    8

    40.2

    56698

    185

    8

    41.9

    56722

    240

    8

    44.4

    56699

    300

    8

    47.5

    56723

    400

    8

    50.1

    56724

    500

    8

    54

    56725

    630

    8

    58.3




  • New
MEDIUM VOLTAGE AWA LSZH COPPER BS7835 MEDIUM VOLTAGE AWA LSZH COPPER BS7835
MEDIUM VOLTAGE AWA LSZH COPPER BS7835
Availability: In Stock
  • CONDUCTOR:  Plain Copper             STRANDING:  Class 2


    INSULATION: XLPE                            METALLIC SCREEN: Plain Copper Taped Screen


    BEDDING: LSZH                                 ARMOUR: Aluminium Wire Armour


    OUTERSHEATH: LSZH                      OUTERSHEATH COLOUR: Red


    RATED VOLTAGE: 6.35/11kV              MINIMUM BENDING RADIUS: 15 x Overall Diameter


    OPERATING TEMPERATURE: 90°C


    STANDARDS:    BS7835, BS EN 60332-1-2.


    Batt Part No.

    Core

    Size

    Colour/Reference

    56182

    1

    70

    Red

    56222

    1

    95

    Red

    56387

    1

    120

    Red

    56600

    1

    50

    Red

    56034

    1

    85

    Red

    56368

    1

    240

    Red

    56229

    1

    300

    Red

    56168

    1

    400

    Red

    56329

    1

    500

    Red

    56035

    1

    630

    Red






    BATT Part No

    Size mm

    RT of insulation mm

    Nominal diameter over CTS mm

    RT of bedding mm

    Diameter over Bedding mm

    Diameter of armour wires mm

    Diameter over Armour mm

    Approx overall Diameter mm

    Weight

    56182

    70

    3.4

    20.2

    1.2

    22.9

    1.6

    26.4

    29

    1500

    56222

    95

    3.4

    22.3

    1.2

    25

    1.6

    28.5

    31

    1800

    56387

    120

    3.4

    23.5

    1.2

    26.2

    1.6

    30.5

    32.5

    2100

    56600

    150

    3.4

    25

    1.5

    27.7

    2

    32

    35

    2400

    56034

    185

    3.4

    26.8

    1.2

    29.5

    2

    33.8

    36.5

    2800

    56368

    240

    3.4

    29.1

    1.2

    31.8

    2

    36.1

    39

    3400

    56229

    300

    3.4

    31.6

    1.2

    34.3

    2

    38.6

    41

    4100

    56168

    400

    3.4

    34.4

    1.2

    37.1

    2

    42.4

    45

    5000

    56329

    500

    3.4

    37.6

    1.3

    40.5

    2.5

    45.8

    49.5

    6300

    630

    630

    3.4

    41.5

    1.4

    44.6

    2.5

    49.9

    54

    7800




  • New
MEDIUM VOLTAGE AWA PVC COPPER BS6622 MEDIUM VOLTAGE AWA PVC COPPER BS6622
MEDIUM VOLTAGE AWA PVC COPPER BS6622
Availability: In Stock
  • CONDUCTOR:    Plain Copper                    STRANDING:       Class 2


    INSULATION:        XLPE                             METALLIC SCREEN:     Plain Copper Taped Screen


    BEDDING:                     PVC                        ARMOUR:                     Aluminium Wire Armour


    OUTERSHEATH:           PVC                       OUTERSHEATH COLOUR:    Red


    RATED VOLTAGE:                  6.35/11kV      MINIMUM BENDING RADIUS:     15 x Overall Diameter


    OPERATING TEMPERATURE:     90°C


    STANDARDS:           BS6622, BS EN 60332-1-2.



    ominal cross sectional area of conductor

    RT of Insulation

    Nominal Diameter over copper screen

    RT of Bedding mm

    Diameter over bedding

    Diameter of armour wire

    Diameter of armour

    Approx overall diameter mm

    Weight

    95

    3.4

    22.3

    1.2

    25

    1.6

    28.5

    32.8

    1850

    120

    3.4

    23.5

    1.2

    26.2

    1.6

    30.5

    34.8

    2160

    150

    3.4

    25

    1.2

    27.7

    2

    32

    36.5

    2590

    185

    3.4

    26.8

    1.2

    29.5

    2

    33.8

    38.3

    2980

    240

    3.4

    29.1

    1.2

    31.8

    2

    36.1

    36.1

    3640

    300

    3.4

    31.6

    1.2

    34.3

    2

    38.6

    38.6

    4330

    400

    3.4

    34.4

    1.2

    37.1

    2.5

    42.4

    42.4.

    5480

    500

    3.4

    37.6

    1.3

    40.5

    2.5

    45.8

    45.8

    6550

    630

    3.4

    41.5

    1.4

    44.6

    2.5

    49.9

    49.9

    8080






  • New
MEDIUM VOLTAGE SWA LSZH COPPER BS7835 MEDIUM VOLTAGE SWA LSZH COPPER BS7835
MEDIUM VOLTAGE SWA LSZH COPPER BS7835
Availability: In Stock
  • CONDUCTOR:   Plain Copper               STRANDING:  Class 2


    INSULATION:  XLPE                             METALLIC SCREEN:    Plain Copper Taped Screen


    BEDDING:   LSZH                                  ARMOUR:  Steel Wire Armour


    OUTERSHEATH: LSZH                         OUTERSHEATH COLOUR: Red


    RATED VOLTAGE:   6.35/11kV


    CORE IDENTIFICATION:   Coloured Tapes: Brown, Black, Grey


    MINIMUM BENDING RADIUS:  12 x Overall Diameter


    OPERATING TEMPERATURE:  90°C               STANDARDS:  BS7835, BS EN 60332-1-2






    Batt Part No.

    Core

    Size

    Colour/Reference

    56182

    1

    70

    Red

    56222

    1

    95

    Red

    56387

    1

    120

    Red

    56600

    1

    150

    Red

    56034

    1

    85

    Red

    56368

    1

    240

    Red

    56229

    1

    300

    Red

    56168

    1

    400

    Red

    56329

    1

    500

    Red

    56035

    1

    630

    Red









    • DE-RATING FACTORS

    Air Temperature °C

    25

    30

    35

    40

    45

    50

    55

    De-Rating Factor

    1

    0.96

    0.92

    0.88

    0.83

    0.78

    0.73


    Ground Temperature °C

    10

    15

    20

    25

    30

    35

    40

    De-Rating Factor

    103

    1

    0.97

    0.93

    0.89

    0.86

    0.82


    Ground Thermal Restistvity km/W

    0.9

    1

    1.2

    1.5

    2

    2.5

    3

    De-Rating Factor

    1.06

    1.04

    1

    0.92

    0.82

    0.74

    0.68


    Depth of Laying m

    0.80

    1

    1.25

    1.50

    1.75

    2

    2.50

    De-Rating Factor

    1

    0.97

    0.95

    0.94

    0.93

    0.91

    0.90



    • DIMENSIONS

    BATT Part No

    Cores

    Nominal cross sectional area of conductor

    Nominal Diameter mm Under armour

    Nominal Diameter mm Over Armour

    Nominal Diameter mm Overall

    Weight

    56182

    1

    70

    23

    26.2

    30.5

    1540

    56222

    1

    95

    24.7

    27.9

    32.8

    1850

    56387

    1

    120

    26.7

    29.9

    33.1

    2200

    56600

    1

    150

    27.5

    31.5

    36

    2600

    56034

    1

    185

    29.3

    33.3

    37.2

    3000

    56368

    1

    240

    31.6

    35.6

    40.8

    3640

    56229

    1

    300

    34.6

    38.6

    42.3

    4300

    56168

    1

    400

    37

    41

    45.2

    5200

    56329

    1

    500

    40.5

    45.5

    49.5

    6500

    56035

    1

    630

    44.6

    49.6

    55.6

    8080

    56140

    3

    25

    -

    -

    48.9

    4300

    56567

    3

    35

    41.6

    46.6

    51.1

    4600

    56568

    3

    50

    44.4

    49.4

    51

    4600

    56570

    3

    70

    48.1

    53.1

    56

    6300

    56569

    3

    95

    52

    57

    63.5

    8200

    56529

    3

    120

    55.6

    60.6

    65.4

    8700

    56538

    3

    150

    58.6

    63.6

    68.6

    9700

    56549

    3

    240

    68.1

    74.4

    78.9

    14300

    56598

    3

    300

    735

    79.8

    84.7

    16600

    56150

    3

    400

    79.3

    84.6

    92.2

    20000



  • New
MEDIUM VOLTAGE SWA PVC ALUMINIUM BS6622 MEDIUM VOLTAGE SWA PVC ALUMINIUM BS6622
MEDIUM VOLTAGE SWA PVC ALUMINIUM BS6622
Availability: In Stock
  • CONDUCTOR:       Aluminium


    STRANDING:        Class 2              INSULATION:         XLPE


    METALLIC SCREEN:                 Plain Copper Taped Screen             BEDDING:   PVC


    ARMOUR:  Steel Wire Armour                 OUTERSHEATH:  PVC


    OUTERSHEATH COLOUR:  Red             RATED VOLTAGE:   6.35/11kV


    CORE IDENTIFICATION:    Coloured tape, Black, Brown & Grey


    MINIMUM BENDING RADIUS: 

    Single core cables: 20 x overall diameter, Multi-core cables: 15 x overall diameter


    OPERATING TEMPERATURE: 90°C


    STANDARDS:

    BS6622: Power cables, thermosetting polymer insulated high voltage IEC60502-2: Power cables with extruded insulation and their accessories for rated voltages from 6kV to 30kV (Um=36kV) Flame Propagation to BS EN 60332-1-2







    Batt Part No.

    Core

    Size

    Colour/Reference

    56507

    3

    95

    Red

    56059

    3

    185

    Red

    56664

    3

    300

    Red









    BATT Part No

    Number of cores

    Nominal cross sectional area of conductor

    Radial thickness of insulation

    Nominal thickness off extruded bedding

    Nominal steel armour wire diameter

    Nominal thickness of oversheath

    Approx overall diameter

    Weight

    56507

    3

    95

     

     

     

     

     

    9800

    56059

    3

    185

     

     

     

     

     

    12250

    56664

    3

    300

     

     

     

     

     

    15500


    BATT Part No

    Continuous current rating in ground

    Continuous current rating in ducts

    Continuous current rating in air

    Trefoil A

    Flat A

    Trefoil A

    Flat A

    Trefoil A

    Flat A

    Trefoil A

    56507

    230

    230

    200

    200

    250

    250

    56059

    335

    335

    290

    290

    385

    385

    56664

    435

    435

    375

    375

    510

    510



  • New
MEDIUM VOLTAGE SWA PVC COPPER BS6622 MEDIUM VOLTAGE SWA PVC COPPER BS6622
MEDIUM VOLTAGE SWA PVC COPPER BS6622
Availability: In Stock
  • CONDUCTOR:    Plain Copper


    STRANDING:      Class 2                INSULATION:    XLPE


    METALLIC SCREEN:    Plain Copper Taped Screen       BEDDING:  PVC


    ARMOUR:      Steel Wire Armour              OUTERSHEATH:     PVC


    OUTERSHEATH COLOUR:   Red             RATED VOLTAGE:          6.35/11kV


    CORE IDENTIFICATION:     Coloured Tapes: Brown, Black, Grey


    MINIMUM BENDING RADIUS:   15 x Overall Diameter  


    OPERATING TEMPERATURE:    90°C


    STANDARDS:   BS 6622, IEC/EN 60228







    Batt Part No.

    Core

    Size

    Colour/Reference

    56535

    3

    70

    Red

    56519

    3

    95

    Red

    56532

    3

    120

    Red

    56520

    3

    150

    Red

    56559

    3

    185

    Red

    56551

    3

    240

    Red








    • DE-RATING FACTORS 

    Air Temperature °C

    25

    30

    35

    40

    45

    50

    55

    De-Rating Factor

    1.00

    0.96

    0.92

    0.88

    0.83

    0.78

    0.73

    Ground Temperature °C

    10

    15

    20

    25

    30

    35

    40

    De-Rating Factor

    1.03

    1.00

    0.97

    0.93

    0.89

    0.86

    0.82

    Ground Thermal Resistivity km/W

    0.9

    1.0

    1.2

    1.5

    2.0

    2.5

    3.0

    De-rating Factor

    1.06

    1.04

    1.00

    0.92

    0.82

    0.74

    0.62

    Depth of Laying m

    0.80

    1.00

    1.25

    1.50

    1.75

    2.00

    2.50

    De-Rating Factor

    1.00

    0.97

    0.95

    0.94

    0.93

    0.91

    0.90


    • ELECTRICAL CHARACTERISTICS

    No of Cores

    Nominal Cross Sectional Area mm2

    Continuous Ratings Amps In Ground Trefoil

    Continuous Ratings Amps In Ground Flat

    Continuous Ratings Amps Ducts Trefoil

    Continuous Ratings Amps in Ducts Flat

    Continuous Ratings Amps In air Trefoil

    Continuous Ratings Amps in air Flat

    3

    70

    250

    250

    215

    215

    270

    270

    3

    95

    300

    300

    255

    255

    330

    330

    3

    120

    340

    340

    290

    290

    380

    380

    3

    150

    380

    380

    330

    330

    430

    430

    3

    185

    430

    430

    370

    370

    490

    490

    3

    240

    500

    500

    430

    430

    570

    570



    • DIMENSIONS

    BATT Part No

    Cores

    Nominal cross sectional area of conductor

    Approx overall diameter

    Weight

    56535

    3

    70

    57.5

    6300

    56519

    3

    95

    61.6

    7500

    56532

    3

    120

    65.4

    9400

    56520

    3

    150

    68.6

    9700

    56559

    3

    185

    72.7

    11400

    56551

    3

    240

    78.9

    14300

    56597

    3

    300

    84.7

    16600



  • New
11KV TRIPLEX ALUMINIUM BS7870 11KV TRIPLEX ALUMINIUM BS7870
11KV TRIPLEX ALUMINIUM BS7870
Availability: In Stock

CONDUCTOR:   Aluminium                    STRANDING:  Class 2


INSULATION:   XLPE                             METALLIC SCREEN:  Copper Wire Screen


ARMOUR:  Plain Copper Wire Braid      OUTERSHEATH:  MDPE


OUTERSHEATH COLOUR:  Red            RATED VOLTAGE: 6.35/11kV


STANDARDS: BS7870-4.10







Batt Part No.

Core

Size

Colour/Reference

56606

3

95

Red

56607

3

185

Red

56608

3

300

Red


Size sq.mm

Weight kg/km

Max DC resistanct at 20°C

Max AC resistance at 90°C

Current rating laid in ground (A)

Current rating laid in air 25°C (A)

95

2901

0.320

0.413

245

285

185

3926

0.164

0.215

353

430

300

5138

0.100

0.133

461

580

 

BATT Part No

Size

Nominal Conductor Diameter mm

Nominal Conductor Screen Thickness

Diameter over Insulation mm

Insulation thickness mm

Diameter over Screen mm

Diameter over Sheath mm

Diameter in Triplex information mm

56606

95

10.65

0.7

18.95

1

23.03

27.12

58.54

56607

185

14.9

0.7

23.25

1

27.33

31.67

68.24

56608

300

19

0.7

27.3

1

31.38

36.12

77.83


  • New
MEDIUM VOLTAGE - ALUMINIUM UK POWER NETWORKS MEDIUM VOLTAGE - ALUMINIUM UK POWER NETWORKS
MEDIUM VOLTAGE - ALUMINIUM UK POWER NETWORKS
Availability: In Stock
  • CONDUCTOR:      Aluminium            STRANDING:   Class 2


    INSULATION:   XLPE                         METALLIC SCREEN:    Aluminium Wire Screen


    OUTERSHEATH:    MDPE                 OUTERSHEATH COLOUR:   Red


    RATED VOLTAGE:   6.35/11kV         STANDARDS:   IEC 60228, IEC 60502-2, IEC 60754-1




    Batt Part No.

    Core

    Size

    Colour/Reference

    56813

    3x1

    95

    Red

    56815

    3x1

    185

    Red

    56816

    3x1

    300

    Red







    BATT Part No

    Cores

    Nominal cross sectional area of conductor

    Approx overall diameter

    Weight

    56813

    3x1

    95

    60

    2440

    56815

    3x1

    185

    72

    3970

    56816

    3x1

    300

    82

    5180




  • New
WRAS APPROVED EPDM DRINKING WATER CABLE WRAS APPROVED EPDM DRINKING WATER CABLE
WRAS APPROVED EPDM DRINKING WATER CABLE
Availability: In Stock
      • CONDUCTOR :   Tinned Copper                STRANDING:   Class 5


        INSULATION:    EPDM                                OUTERSHEATH:   EPDM


        OUTERSHEATH COLOUR:   Light Blue     RATED VOLTAGE:    450/750v


        CORE IDENTIFICATION: 

        Single core - Black

        4 core - Green/Yellow, Brown, Black, Grey


        MINIMUM BENDING RADIUS: 

        Fixed: 3 x overall diameter / Flexed: 5 x overall diameter


        OPERATING TEMPERATURE: 

        Temperature Rating: -25°C to +90°C / Maximum Water Temperature: +80°C


        STANDARDS: 

        WRAS approved Certificates available on request







        Batt Part No.

        Core

        Size

        Colour/Reference

        21032

        1

        25

        Light Blue

        21017

        1

        50

        Light Blue

        21018

        1

        70

        Light Blue

        21019

        1

        95

        Light Blue

        21031

        1

        120

        Light Blue

        21028

        4

        1.5

        Light Blue

        21014

        4

        2.5

        Light Blue 

        21025

        4

        4

        Light Blue

        21022

        4

        6

        Light Blue

        21029

        4

        10

        Light Blue

        21026

        4

        16

        Light Blue

        21016

        4

        25

        Light Blue

        21020

        4

        35

        Light Blue

        21021

        4

        50

        Light Blue 

        21015

        4

        70

        Light Blue

        21023

        4

        95

        Light Blue

        21013

        4

        120

        Light Blue

        21024

        7

        2.5

        Light Blue


        BATT Part No

        No of cores

        Nominal cross sectional area of conductor (mm2)

        Approx overall diameter (mm)

        Weight (kg/km)

        21032

        1

        25

        11.7

        305

        21017

        1

        50

        15.3

        570

        21018

        1

        70

        17.6

        795

        21019

        1

        95

        19.7

        1030

        21031

        1

        120

        22.2

        1305

        21028

        4

        1.5

        10.2

        135

        21014

        4

        2.5

        11.8

        200

        21025

        4

        4

        13.2

        270

        21022

        4

        6

        14.6

        380

        21029

        4

        10

        18.8

        630

        21026

        4

        16

        21.1

        870

        21016

        4

        25

        26.3

        1310

        21020

        4

        35

        29.4

        1725

        21021

        4

        50

        34.7

        2490

        21015

        4

        70

        39.8

        3420

        21023

        4

        95

        45.4

        4480

        21013

        4

        120

        50.6

        5605

        21024

        7

        2.5

         

         

        ELECTRICAL CHARACTERISTICS

        Nominal cross sectional area (mm2)

        Current carrying capacity (Laying in Air)

        Current carrying capacity (Laying in Water)

        1.5

        23

        29

        2.5

        32

        38

        4

        42

        52

        6

        54

        67

        10

        75

        94

        16

        100

        125

        25

        127

        166

        35

        158

        205

        50

        192

        256

        70

        246

        316

        95

        298

        377

        120

        346

        438

        150

        399

        505

        185

        456

        577

        240

        538

        681

        300

        621

        785

        Conductor temperature: +90°C

        Ambient air/water temperature: +30°C



  • New
0361-TQ SINGLE CORE WELDING CABLE 0361-TQ SINGLE CORE WELDING CABLE
0361-TQ SINGLE CORE WELDING CABLE
Availability: In Stock
  • CONDUCTOR:   Tinned Copper              STRANDING:   Class 6


    INSULATION:   EPR                               OUTERSHEATH:   CSP


    OUTERSHEATH COLOUR:   Black, Orange


    MINIMUM BENDING RADIUS:   Overall Bending Radius 6x


    OPERATING TEMPERATURE:  85°C


    STANDARDS:

    BS638 part 4 * (withdrawn). EN 60228 Flame Retardant according to IEC/EN 60332-1-2   







    • DE-RATING FACTORS

    Ambient Temperature

    25°C

    30°C

    35°C

    40°C

    45°C

    De-Rating Factor

    1

    0.96

    0.91

    0.87

    0.82


    • The above table is in accordance with Table A.7 of BS 638 Part 4

      ELECTRICAL CHARACTERISTICS Duty Cycle and Current Carrying Capacity The current carrying capacity of a welding cable depends on the length of the duty cycle. The duty cycle is the length of time during which a loaded current passes through the cable over an operation
      CURRENT CARRYING CAPACITY

    Nomincal Cross Sectional Area mm2

    Current Rating for Single Cycle Operation Over A Maximim Period Of 5 Minutes Amps 100%

    Current Rating for Single Cycle Operation Over A Maximim Period Of 5 Minutes Amps85%

    Current Rating for Single Cycle Operation Over A Maximim Period Of 5 Minutes Amps 60%

    Current Rating for Single Cycle Operation Over A Maximim Period Of 5 Minutes Amps 35%

    16

    135

    145

    175

    230

    25

    180

    195

    230

    300

    35

    225

    245

    290

    375

    50

    285

    305

    365

    480

    70

    355

    385

    460

    600

    95

    430

    470

    560

    730

    120

    500

    540

    650

    850

    150

    580

    630

    750

    980

    185

    665

    720

    860

    1120

    240

    780

    850

    975

    1250



    • Class 5 Flexible Copper Conductors for Single Core and Multi-Core Cables

    Nominal Cross Sectional Area mm2

    Maximum Diameter of Wires in Conductors mm

    Maximum Resistance of Conductor at 20ºC ohms/km

    Plain Wires

    120

    0.51

    0.161

    150

    0.51

    0.129

    185

    0.51

    0.106

    240

    0.51

    0.0817



    • CONDUCTORS
      Class 6 Flexible Copper Conductors for Single Core and Multi-Core Cables
       

    Nominal Cross Sectional Area mm2

    Maximum Diameter Of Wires In Conductor mm

    Maximum Resistance Of Conductor at  20ºC ohms/km

    Plain Wires

    16

    0.21

    1.21

    25

    0.21

    0.78

    35

    0.21

    0.554

    50

    0.21

    0.386

    70

    0.21

    0.272

    95

    0.21

    0.206



    • DIMENSIONS
      Type 0361TQ - Tinned Copper Conductors

    BATT Part No

    Conductor Class

    Nominal cross sectional area of conductor

    Total Radial thickness of covering

    Approx overall diameter

    Weight

    19003

    6

    16

    2

    10.9

    212

    19006

    6

    25

    2

    12.5

    300

    19012

    6

    35

    2

    14

    403

    19034

    6

    50

    2.2

    16

    560

    19036

    6

    70

    2.4

    18.6

    776

    19042

    6

    95

    2.6

    21.2

    1035

    19029

    5

    120

    2.8

    23.1

    1300

    19031

    5

    150

    3

    24

    1900

    19032

    5

    185

    3.2

    27.9

    1944

    19060

    5

    240

    3.4

    31.5

    1064


    Batt Part No.

    Core

    Size

    Colour/Reference

    19003

    1

    16

    Orange

    19024

    1

    16

    Black

    19006

    1

    25

    Orange

    19023

    1

    25

    Black

    19012

    1

    35

    Orange

    19009

    1

    35

    Black

    19034

    1

    50

    Orange

    19005

    1

    50

    Black

    19036

    1

    70

    Orange

    19004

    1

    70

    Black

    19042

    1

    95

    Orange

    19050

    1

    95

    Black

    19029

    1

    120

    Orange

    19025

    1

    120

    Black

    19031

    1

    150

    Orange

    19048

    1

    150

    Black

    19032

    1

    185

    Orange

    19049

    1

    185

    Black


    •  period of 5 minutes, expressed as a percentage of that period. For example, if the current is flowing for the whole 5 minutes the duty cycle is 100%, and if the current is flowing for 1 minute the duty cycle is 20%. As conductor temperature varies according to the time in use as well as current, ratings shown are given as a guide. The permissible loading of the cable for duty cycles other than those shown in the table can be calculated using the following formula: I = I100 x √100/F Where: I: is the maximum permissible loading current for the required duty cycle. I 100 : is the maximum permissible loading current for a duty cycle of 100%. F : is the required duty cycle calculated as a percentage of the 5 minute operation period. Typical guidance values for different welding processes are as follows: Fully automatic welding 100% Semi-automatic welding 65 - 85% Manual welding 30 - 60% Very infrequent or occasional welding 20%


  • New
HI FLEX PVC WELDING CABLE HI FLEX PVC WELDING CABLE
HI FLEX PVC WELDING CABLE
Availability: In Stock

CONDUCTOR:     Plain Copper                                 INSULATION:     PVC


OUTERSHEATH COLOUR:   Black, Red                    RATED VOLTAGE:   750V


MINIMUM BENDING RADIUS:    Overall Bending Radius 6x


OPERATING TEMPERATURE:    70°C


STANDARDS: 

IEC60331: Tests for electric cables under fire conditions - circuit integrity IEC60332-1: Tests on electric and optical fibre cables under fire conditions Part 1: test for vertical flame propagation for a single insulated wire or cable BSEN50265: Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cables







Batt Part No.

Core

Size

Colour/Reference

19008

1

16

Black

19010

1

16

Red

19016

1

25

Black

19022

1

25

Red

19038

1

35

Black

19039

1

35

Red

19040

1

50

Black

19041

1

50

Red

19044

1

70

Black

19053

1

70

Red

19058

1

95

Black

19057

1

95

Red


BATT Part No

Nominal cross sectional area of conductor

Nomincal conductor construction

Nominal diameter of conductor mm

Outer diameter of insutlation

Insutlation thickness mm AV

Insutlation thickness mm Min

Min insutlation Resistance Ohms

Approx Weight kg/km

19008

16

204 x 0.3

5.2

8.7

1.4

1.16

1.28

200

19016

25

324 x 0.3

6.5

10.5

1.5

1.25

0.85

300

19038

35

444 x 0.3

7.8

12

1.7

1.53

0.58

410

19040

50

636 x 0.3

8.8

13.8

1.7

1.43

0.41

565

19044

70

900 x 0.3

10.8

15.9

1.9

1.61

0.28

780

19058

95

1308 x 0.3

 

 

2

1.7

 

 

15185

120

1680 x 0.3

 

 

2

1.7

 

 



  • New
Top Electrical Equipment & Supplies in Africa | Wholesale B2B Marketplace

Find high-quality electrical equipment and supplies on our leading B2B platform in Africa. Shop top brands with competitive prices, fast shipping, and reliable service, ideal for retailers and bulk buyers across the continent.

busy...