One Africa-One Market - Your Borderless B2B Sourcing Portal

Become a Merchant

Welcome To Zandaux

  • Vendor login
  • Track Your Order
  • Support
Batt cables
WRAS APPROVED EPDM DRINKING WATER CABLE
Availability:
In Stock
Condition:
New
Request Quote
Logo Netherlands

These WRAS approved cables are designed for submersible pump operation in drinking water and various water environments. Featuring a non-toxic, non-leaching cross-linked rubber jacket, they prevent microbial growth and maintain water quality. Suitable for permanent immersion, they are ideal for fishponds, swimming pools, and food manufacturing. With WRAS approval, they ensure water safety and integrity, offering reliability in water treatment operations. 


Technical Details:

UPC: 120000136
Seller SKU: bnc0000137
Condition: New
Availability: In Stock
Minimum order quantity: 100
Date first listed on Zandaux: Jun 26, 2024
      • CONDUCTOR :   Tinned Copper                STRANDING:   Class 5


        INSULATION:    EPDM                                OUTERSHEATH:   EPDM


        OUTERSHEATH COLOUR:   Light Blue     RATED VOLTAGE:    450/750v


        CORE IDENTIFICATION: 

        Single core - Black

        4 core - Green/Yellow, Brown, Black, Grey


        MINIMUM BENDING RADIUS: 

        Fixed: 3 x overall diameter / Flexed: 5 x overall diameter


        OPERATING TEMPERATURE: 

        Temperature Rating: -25°C to +90°C / Maximum Water Temperature: +80°C


        STANDARDS: 

        WRAS approved Certificates available on request







        Batt Part No.

        Core

        Size

        Colour/Reference

        21032

        1

        25

        Light Blue

        21017

        1

        50

        Light Blue

        21018

        1

        70

        Light Blue

        21019

        1

        95

        Light Blue

        21031

        1

        120

        Light Blue

        21028

        4

        1.5

        Light Blue

        21014

        4

        2.5

        Light Blue 

        21025

        4

        4

        Light Blue

        21022

        4

        6

        Light Blue

        21029

        4

        10

        Light Blue

        21026

        4

        16

        Light Blue

        21016

        4

        25

        Light Blue

        21020

        4

        35

        Light Blue

        21021

        4

        50

        Light Blue 

        21015

        4

        70

        Light Blue

        21023

        4

        95

        Light Blue

        21013

        4

        120

        Light Blue

        21024

        7

        2.5

        Light Blue


        BATT Part No

        No of cores

        Nominal cross sectional area of conductor (mm2)

        Approx overall diameter (mm)

        Weight (kg/km)

        21032

        1

        25

        11.7

        305

        21017

        1

        50

        15.3

        570

        21018

        1

        70

        17.6

        795

        21019

        1

        95

        19.7

        1030

        21031

        1

        120

        22.2

        1305

        21028

        4

        1.5

        10.2

        135

        21014

        4

        2.5

        11.8

        200

        21025

        4

        4

        13.2

        270

        21022

        4

        6

        14.6

        380

        21029

        4

        10

        18.8

        630

        21026

        4

        16

        21.1

        870

        21016

        4

        25

        26.3

        1310

        21020

        4

        35

        29.4

        1725

        21021

        4

        50

        34.7

        2490

        21015

        4

        70

        39.8

        3420

        21023

        4

        95

        45.4

        4480

        21013

        4

        120

        50.6

        5605

        21024

        7

        2.5

         

         

        ELECTRICAL CHARACTERISTICS

        Nominal cross sectional area (mm2)

        Current carrying capacity (Laying in Air)

        Current carrying capacity (Laying in Water)

        1.5

        23

        29

        2.5

        32

        38

        4

        42

        52

        6

        54

        67

        10

        75

        94

        16

        100

        125

        25

        127

        166

        35

        158

        205

        50

        192

        256

        70

        246

        316

        95

        298

        377

        120

        346

        438

        150

        399

        505

        185

        456

        577

        240

        538

        681

        300

        621

        785

        Conductor temperature: +90°C

        Ambient air/water temperature: +30°C