Instrumentation cables, manufactured to PAS5308 standards, ensure safety and reliability for communication and instrumentation applications in process industries, transmitting analogue or digital signals from various sensors and transducers. These cables, featuring steel wire armour (SWA), provide exceptional protection in aggressive environments.

Designed for indoor and outdoor installations in industrial process plants and for data and voice transmission services, they are also used to interconnect electrical equipment and instruments, particularly in process plants. These cables are widely utilized throughout the petroleum industry.

Type 2 armoured cables are suitable for direct burial installations.


Technical Details:

UPC: 120000061
Seller SKU: bnc0000063
Condition: New
Availability: In Stock
Minimum order quantity: 100
Date first listed on Zandaux: Jun 19, 2024


CONDUCTOR: Plain Copper  STRANDING: See Spec. Table  INSULATION: PE


COLLECTIVE SCREEN: Collective Aluminium Mylar    BEDDING : PE


ARMOUR: Steel Wire Armour  OUTERSHEATH: PVC OUTERSHEATH COLOUR:  Black, Blue


RATED VOLTAGE: 500V   CORE IDENTIFICATION : According to BS5308 part 1


OPERATING TEMPERATURE : 70ºC  STANDARDS : BS/PAS 5308, EN 60228




Batt Part No.

Cores

Size

Colour/Reference

85123

1P

0.5

Black

85001

1P

0.5

Blue

85251

1P

0.75

Black

85250

1P

0.75

Blue

85181

1P

1

Black

85226

1P

1

Blue

85012

1P

1.5

Black

85011

1P

1.5

Blue

85691

1P

2.5

Black

-

1P

2.5

Blue

85163

1T

0.5

Black

85116

1T

0.5

Blue

85252

1T

0.75

Black

-

1T

0.75

Blue

-

1T

1

Black

-

1T

1

Blue

85114

1T

1.5

Black

85139

1T

1.5

Blue

-

1T

2.5

Black

-

1T

2.5

Blue

85113

2P(Q)

0.5

Black

85227

2P(Q)

0.5

Blue

85416

2P(Q)

0.75

Black

85619

2P(Q)

0.75

Blue

85187

2P(Q)

1

Black

85267

2P(Q)

1

Blue

85243

2P(Q)

1.5

Black

85478

2P(Q)

1.5

Blue

-

2P(Q)

2.5

Black

-

2P(Q)

2.5

Blue

85120

5P

0.5

Black

85018

5P

0.5

Blue

85418

5P

0.75

Black

85583

5P

0.75

Blue

85031

5P

1

Black

-

5P

1

Blue

85118

5P

1.5

Black

85688

5P

1.5

Blue

85175

5P

2.5

Black

-

5P

2.5

Blue

85030

10P

0.5

Black

85029

10P

0.5

Blue

85419

10P

0.75

Black

85620

10P

0.75

Blue

85454

10P

1

Black

-

10P

1

Blue

85494

10P

1.5

Black

85311

10P

1.5

Blue

85692

10P

2.5

Black

-

10P

2.5

Blue

-

15P

0.5

Black

-

15P

0.5

Blue

-

15P

0.75

Black

-

15P

0.75

Blue

-

15P

1

Black

-

15P

1

Blue

-

15P

1.5

Black

-

15P

1.5

Blue

-

15P

2.5

Black

-

15P

2.5

Blue

85307

20P

0.5

Black

85711

20P

0.5

Blue

85501

20P

0.75

Black

85621

20P

0.75

Blue

-

20P

1

Black

-

20P

1

Blue

85689

20P

1.5

Black

85690

20P

1.5

Blue

86551

20P

2.5

Black

-

20P

2.5

Blue

-

30P

0.5

Black

-

30P

0.5

Blue

-

30P

0.75

Black

85605

30P

0.75

Blue

-

30P

1

Black

-

30P

1

Blue

86837

30P

1.5

Black

85769

30P

1.5

Blue

-

30P

2.5

Black

-

30P

2.5

Blue

 

 

 

 


No. of Pairs/Triples

Nominal cross sectional area of conductor (mm)

Approx overall diameter (mm)

1P

0.5

11.4

1P

0.75

11.8

1P

1

11.8

1P

1.5

12.9

1P

2.5

13.7

1T

0.5

11.7

1T

0.75

12.1

1T

1

12.3

1T

1.5

13.5

1T

2.5

14.3

2P(Q)

0.5

12.3

2P(Q)

0.75

13.0

2P(Q)

1

13.0

2P(Q)

1.5

14.3

2P(Q)

2.5

15.3

5P

0.5

17.9

5P

0.75

19.3

5P

1

19.7

5P

1.5

22.1

5P

2.5

24.1

10P

0.5

22.9

10P

0.75

25.5

10P

1

24.3

10P

1.5

28.4

10P

2.5

32.1

15P

0.5

26.4

15P

0.75

28.7

15P

1

28.1

15P

1.5

32.2

15P

2.5

36.4

20P

0.5

29.1

20P

0.75

31.6

20P

1

31.2

20P

1.5

35.7

20P

2.5

41

Conductors

Nominal cross sectional area (mm²)

Conductor class

Maximum DC resistance of conductor at 20° (ohms/km)

0.5

5

39

0.75

5

26

1

1

18.1

1.5

2

12.1

2.5

2

7.41

Electrical Characteristics 

Nominal cross sectional area

Maximum mutual capacitance (pF/m)

Minimum insulation resistance at 20°C

Maximum L/R ratio (µH/ohms)

 

Cables with collective screens only

1 pair, 2 pairs, 1 triple, collectively screened

Cables with individually screened pairs

 

 

0.5

75

115

115

<5

25

0.75

75

115

115

<5

25

1

75

115

115

<5

25

1.5

85

120

120

<5

40

2.5

85

120

120

<

65

Core Identification

Pair No

A Wire

B Wire

1

Black

Blue

2

Black

Green

3

Blue

Green

4

Black

Brown

5

Blue

Brown

6

Green

Brown

7

Black

White

8

Blue

White

9

Green

White

10

Brown

White

11

Black

Red

12

Blue

Red

13

Green

Red

14

Brown

Red

15

White

Red

16

Black

Orange

17

Blue

Orange

18

Green

Orange

19

Brown

Orange

20

White

Orange

21

Red

Orange

22

Black

Yellow

23

Blue

Yellow

24

Green

Yellow

25

Brown

Yellow

26

White

Yellow

27

Red

Yellow

28

Orange

Yellow

29

Black

Grey

30

Blue

Grey

31

Green

Grey

32

Brown

Grey

33

White

Grey

34

Red

Grey

35

Orange

Grey

36

Yellow

Grey

37

Black

Violet

38

Blue

Violet

39

Green

Violet

40

Brown

Violet

41

White

Violet

42

Red

Violet

43

Orange

Violet

44

Yellow

Violet

45

Grey

Violet

46

Black

Turquoise

47

Blue

Turquoise

48

Green

Turquoise

49

Brown

Turquoise

50

White

Turquoise



No reviews

busy...
Batt cables
Batt Cables (Online)

We're just one step away! Please login to start the conversation. Login