One Africa-One Market - Your Borderless B2B Sourcing Portal

Become a Merchant

Welcome To Zandaux

  • Vendor login
  • Track Your Order
  • Support
Sort by:
Batt Cable N2XH-J LSZH POWER CABLE  | MOQ (500 Meters) Batt Cable N2XH-J LSZH POWER CABLE  | MOQ (500 Meters)
Batt Cable N2XH-J LSZH POWER CABLE | MOQ (500 Meters)
Availability: In Stock

CONDUCTOR : Plain Copper STRANDING : Class 1 INSULATION : XLPE

OUTERSHEATH : LSZH OUTERSHEATH COLOUR : Black


RATED VOLTAGE : 0.6/1kV


CORE IDENTIFICATION

2 core: brown, blue

3 core: blue, brown and green/yellow

4 core: brown, black, grey and green/yellow

5 core: black, blue, brown, grey and green/yellow

7 core + : Numbered and green/yellow


MINIMUM BENDING RADIUS

During Installation: 15 x overall diameter Fixed: 10 x overall diameter


OPERATING TEMPERATURE

Fixed: -20°C to +90°C


STANDARDS

VDE 0276 part 604, VDE 0482 part 267, HS 604 S1, HS627 S1, EN 50575:2014 + EN 50575/A1:2016, IEC 60502-1



BATT Part No

NO. OF CORES

NOMINAL CROSS SECTIONAL AREA mm2

CONDUCTOR TYPE

NOMINAL THICKNESS OF INSULATION mm

NOMINAL OVERALL DIAMETER mm

NOMINAL WEIGHT kg/km

45526

1

240

RM

1.7

24.4

2525

45509

2

1.5

RE

0.7

12

125

45681

2

2.5

RE

0.7

12.1

155

45506

3

1.5

RE

0.7

12

145

45507

3

2.5

RE

0.7

13

180

45501

3

4

RE

0.7

14

235

45508

3

6

RE

0.7

15

325

45669

3

10

RE

0.7

15.4

485

45670

3

16

RE

0.7

17.1

705

45680

3

25

RM

0.9

20.5

1080

45671

3

35

SM

0.9

22.8

1425

45547

4

1.5

RE

0.7

12

170

45529

4

2.5

RE

0.7

13

215

45525

4

4

RE

0.7

14.5

290

45539

4

6

RE

0.7

16

390

45682

4

10

RE

0.7

18.5

600

45683

4

16

RE

0.7

21

870

45603

4

25

RM

0.9

25.5

1365

45604

4

35

SM

0.9

28.5

1875

45789

4

50

SM

1

31.1

2550

45790

4

70

SM

1.1

36.2

3010

45791

4

95

SM

1.1

40.6

3960

45722

4

150

SM

1.4

49.5

6150

45786

4

185

SM

1.6

54.4

7780

45523

5

1.5

RE

0.7

13

195

45502

5

2.5

RE

0.7

14.5

255

45503

5

4

RE

0.7

16

345

45504

5

6

RE

0.7

17.5

475

45783

5

10

RE

0.7

20

735

45792

5

16

RE

0.7

23

1070

45793

5

25

RM

0.9

25.6

1605

45810

5

35

RM

0.9

28.7

2139

45546

7

1.5

 

 

 

 

45711

7

2.5

 

 

 

 

45524

12

1.5

 

 

 

 

45540

12

2.5

 

 

 

 

 

ELECTRICAL CHARACTERISTICS

Current Carrying Capacity at 30°C

NOMINAL CROSS SECTIONAL AREA mm

1 CORE IN GROUND

1 CORE IN AIR

2 CORE IN GROUND

2 CORE IN AIR

3&4 CORE IN GROUND

3&4 CORE IN AIR

7 CORE IN AIR

10 CORE IN AIR

12&14 CORE IN AIR

19 CORE IN AIR

24 CORE IN AIR

1.5

31

24

37

26

31

23

18

16

14

13

12

2.5

41

33

48

36

41

31

23

22

20

18

16

4

59

45

63

49

53

42

 

 

 

 

 

6

101

58

80

63

66

54

 

 

 

 

 

10

128

80

104

86

87

75

 

 

 

 

 

16

144

107

136

115

113

100

 

 

 

 

 

25

174

138

173

149

144

127

 

 

 

 

 

35

206

169

 

 

174

158

 

 

 

 

 

50

254

207

 

 

206

192

 

 

 

 

 

70

301

268

 

 

254

246

 

 

 

 

 

95

343

328

 

 

301

298

 

 

 

 

 

120

387

382

 

 

343

346

 

 

 

 

 

150

434

441

 

 

387

395

 

 

 

 

 

185

501

506

 

 

434

450

 

 

 

 

 

240

565

599

 

 

501

538

 

 

 

 

 

300

565

693

 

 

 

 

 

 

 

 

 

400

749

811

 

 

 

 

 

 

 

 

 

500

843

940

 

 

 

 

 

 

 

 

 


  • New
Batt Cable NYY-J & NYY-O PVC CABLE | MOQ (500 Meters) Batt Cable NYY-J & NYY-O PVC CABLE | MOQ (500 Meters)
Batt Cable NYY-J & NYY-O PVC CABLE | MOQ (500 Meters)
Availability: In Stock

CONDUCTOR : Plain Copper STRANDING : Class 2 INSULATION : PVC

OUTERSHEATH : PVC OUTERSHEATH COLOUR : Black


RATED VOLTAGE : 0.6/1kV


CORE IDENTIFICATION

Single core: Black

Two core: Brown and Blue

Three core: Brown, Blue and Green / Yellow

Four core: Black, Grey, Brown and Green / Yellow

Five core: Black, Blue. Brown, Grey and Green / Yellow

Seven - Forty cores: Black cores, numbered and Green / Yellow


MINIMUM BENDING RADIUS

Fixed: 12 x overall diameter


OPERATING TEMPERATURE

Max 70ºC


STANDARDS

IEC 60502-1, VDE 0276-603, HD 603, IEC 60228 Flame retardant according to IEC/EN 60332-1-2



BATT Part No

NO. OF CORES

NOMINAL CROSS SECTIONAL AREA mm2

CONDUCTOR TYPE

NOMINAL THICKNESS OF INSULATION mm

NOMINAL THICKNESS OF SHEATH mm

NOMINAL OVERALL DIAMETER mm

NOMINAL WEIGHT kg/km

16946

1

6

RE

1

.4

6.15

62

16947

1

10

RM

1

1.4

8.6

155

16836

1

16

RM

1

1.4

9.6

218

16837

1

25

RM

1.2

1.4

11.1

318

16838

1

35

RM

1.2

1.4

12.1

414

16839

1

50

RM

1.4

1.4

13.7

552

16840

1

70

RM

1.4

1.4

15.5

750

16100

1

95

RM

1.6

1.5

17.6

1020

16905

1

120

RM

1.6

1.6

19.3

1259

16904

1

150

RM

1.8

1.6

21

1546

16211

1

185

RM

2

1.7

23.2

1913

16903

1

240

RM

2.2

1.8

26.2

2471

16813

1

300

RM

2.4

2

29.2

3097

16984

1

500

 

 

 

 

 

16486

2

1

 

 

 

 

 

16663

2

1.5

RE

0.8

1.8

10

147

16502

2

2.5

RE

0.8

1.8

10.7

179

16299

2

4

RM

1

1.8

13

268

16722

2

6

RM

1

1.8

14.2

337

16398

2

10

RM

1

1.8

16.2

472

16375

2

16

RM

1

1.8

18.2

644

16401

2

25

 

 

 

 

 

16503

3

1.5

RE

0.8

1.8

10.4

166

16408

3

2.5

RE

0.8

1.8

11.3

212

16597

3

4

RE

1

1.8

13.1

299

16591

3

6

RM

1

1.8

15

402

16683

3

10

RM

1

1.8

17.1

570

16714

3

16

RM

1

1.8

19.2

789

16616

3

25

RM

1.2

1.8

22.1

1141

16773

3

35

RM

1.2

1.8

24.1

1462

16841

3

50

RM

1.4

1.8

27.6

1964

16675

3

70

RM

1.6

2.1

36.3

3635

16386

3

95

RM

1.6

2.2

40

4488

16595

4

1.5

RE

0.8

1.8

11.6

198

16676

4

2.5

RE

0.8

1.8

12.1

252

16709

4

4

RM

1

1.8

15.1

391

16729

4

6

RM

1

1.8

16.5

465

16731

4

10

RM

1

1.8

18.6

702

16752

4

16

RM

1

1.8

21.1

992

16500

4

25

RM

1.2

1.8

24.2

1431

16501

4

35

RM

1.2

1.8

26.6

1861

16481

4

50

RM

1.4

1.9

30.9

2535

16596

4

70

RM

1.4

2.1

35.1

3441

16629

4

95

RM

1.6

2.2

404

4691

16630

4

185

RM

2

2.7

53.9

8810

16605

5

1.5

RE

0.8

1.8

12

232

16505

5

2.5

RE

0.8

1.8

13.1

302

16685

5

4

RM

1

1.8

16.6

477

16672

5

6

RM

1

1.8

18.2

618

16692

5

10

RM

1

1.8

20.3

853

16686

5

16

RM

1

1.8

26.6

1212

16325

5

25

 

 

 

 

 

16589

5

35

 

 

 

 

 

16010

5

120

 

 

 

 

 

16193

7

1.5

RE

1

0.8

14.1

368

16161

7

2.5

RE

1

1.8

16.6

477

16226

7

4

 

 

 

 

 

16308

12

1.5

RE

0.8

1.8

16.6

475

16244

12

2.5

RE

0.8

1.8

16.2

628

16228

19

1.5

RE

0.8

1.8

18.9

648

16774

19

2.5

RE

0.8

1.8

20.3

843

16247

21

1.5

 

 

 

 

 

16339

40

2.5

 

 

 

 

 

 

CONDUCTORS

Class 1 Solid Conductors for Single Core and Multi-Core Cables

NOMINAL CROSS SECTIONAL AREA mm2

MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC ohms/km - Circular, Annealed Copper Conductor - Plain Wires

1.5

12.1

2.5

7.41

4

4.61

6

3.08

10

1.83

16

1.15

25

0.727

35

0.524

50

0.387

70

0.268

95

0.193

120

0.153

150

0.124

185

0.101

240

0.0775

300

0.062

 

Class 2 Stranded Conductors for Single Core and Multi-Core Cables

 

NOMINAL CROSS SECTIONAL AREA mm2

MINIMUM NO. OF WIRES IN CONDUCTOR - Circular cu

MINIMUM NO. OF WIRES IN CONDUCTOR - Circular cu

MINIMUM NO. OF WIRES IN CONDUCTOR - Circular Compacted cu

MINIMUM NO. OF WIRES IN CONDUCTOR - Circular Compacted al

MINIMUM NO. OF WIRES IN CONDUCTOR - Shaped cu

MINIMUM NO. OF WIRES IN CONDUCTOR - Shaped al

MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC - Annealed Copper Conductor - Plain wires ohms/km

1.5

7

 

6

 

 

 

12.1

2.5

7

 

6

 

 

 

7.41

4

7

 

6

 

 

 

4.61

6

7

 

6

 

 

 

3.08

10

7

7

6

6

 

 

1.83

16

7

7

6

6

 

 

1.15

25

7

7

6

6

6

6

0.727

35

7

7

6

6

6

6

0.524

50

19

19

6

6

6

6

0.387

70

19

19

12

12

12

12

0.268

95

19

19

15

15

15

15

0.193

120

37

37

18

15

18

15

0.153

150

37

37

18

15

18

15

0.124

185

37

37

30

30

30

30

0.0991

240

37

37

34

30

34

30

0.0754

300

61

61

34

30

34

30

0.0601

 

ELECTRICAL CHARACTERISTICS Current Carrying Capacity

NO. OF CORES

NOMINAL CROSS SECTIONAL AREA mm2

CONDUCTOR TYPE

CURRENT CARRYING CAPACITY IN DUCT Amps

CURRENT CARRYING CAPACITY IN AIR Amps

1

2.5

 

 

26

1

4

 

 

57

1

6

 

 

57

1

10

 

 

78

1

16

 

127

103

1

25

 

103

137

1

35

 

195

169

1

50

 

230

206

1

70

 

282

261

1

95

 

336

321

1

120

 

382

374

1

150

 

428

428

1

185

 

483

414

1

240

 

561

590

1

300

 

632

678

2

1.5

 

32

20

2

2.5

 

42

27

2

4

 

54

37

2

6

 

68

48

2

10

 

90

66

2

16

 

116

89

3

1.5

 

26

18

3

2.5

 

34

25

3

4

 

44

34

3

4

 

44

34

3

6

 

56

43

3

6

 

56

43

3

10

 

75

60

3

16

 

98

80

3

25

 

128

106

3

35

 

157

131

3

50

 

185

159

3

95

 

275

244

3

120

 

313

282

4

1.5

 

26

18

4

2.5

 

34

25

4

4

 

44

34

4

4

 

44

34

4

6

 

56

43

4

6

 

56

43

4

10

 

75

60

4

16

 

98

80

4

25

 

128

106

4

35

 

157

131

4

50

 

185

159

4

70

 

252

247

4

95

 

303

305

4

120

 

313

282

4

150

 

390

407

4

185

 

399

371

4

240

 

464

436

5

1.5

 

24

18

5

2.5

 

34

25

5

4

 

44

34

5

4

 

44

34

5

6

 

56

43

5

6

 

56

43

5

10

 

75

60

5

16

 

98

80

5

25

 

128

106

7

1.5

 

15

12

7

2.5

 

20

16

12

1.5

 

12

9

12

2.5

 

16

13

14

1.5

 

12

9

19

1.5

 

10

8

19

2.5

 

13.6

11.3

27

1.5

 

12

9

 

DE-RATING FACTORS For Air Temperature other than 30°C

 

AIR TEMPERATURE

20ºC

25ºC

30ºC

35ºC

40ºC

45ºC

50ºC

DE-RATING FACTOR

1.12

1.07

1.00

0.94

0.87

0.79

0.71



Batt Part No.

Core

Size

Colour/Reference

16946

1

6

Black

16944

1

10

Black

16947

1

10

Black

16836

1

16

Black

16945

1

16

Black

16837

1

25

Black

16838

1

35

Black

16839

1

50

Black

16840

1

70

Black

16100

1

95

Black

16905

1

120

Black

16904

1

150

Black

16211

1

185

Black

16903

1

240

Black

83059

1

240

Black

16813

1

300

Black

16984

1

500

Black

16486

2

1

Black

16663

2

1.5

Black

16502

2

2.5

Black

16299

2

4

Black

16722

2

6

Black

16398

2

10

Black

16375

2

16

Black

16401

2

25

Black

16503

3

1.5

Black

16408

3

2.5

Black

16504

3

2.5

Black

16597

3

4

Black

16591

3

6

Black

16683

3

10

Black

16717

3

10

Black

16714

3

16

Black

16616

3

25

Black

16773

3

35

Black

16841

3

50

Black

16675

3

70

Black

16386

3

95

Black

16595

4

1.5

Black

16676

4

2.5

Black

16709

4

4

Black

16729

4

6

Black

16966

4

6

Black

16731

4

10

Black

16752

4

16

Black

16500

4

25

Black

16501

4

35

Black

16481

4

50

Black

16696

4

50

Black

16596

4

70

Black

16629

4

95

Black

16630

4

185

Black

16605

5

1.5

Black

16505

5

2.5

Black

16685

5

4

Black

16672

5

6

Black

16692

5

10

Black

16686

5

16

Black

16325

5

25

Black

16589

5

35

Black

16010

5

120

Black

16193

7

1.5

Black

16161

7

2.5

Black

16226

7

4

Black

16308

12

1.5

Black

16244

12

2.5

Black

16228

19

1.5

Black

16774

19

2.5

Black

16247

21

1.5

Black

16339

40

2.5

Black


  • New
Batt Cable 218-Y / H03VV-F PVC FLEXIBLE CABLE | MOQ (500 Meters) Batt Cable 218-Y / H03VV-F PVC FLEXIBLE CABLE | MOQ (500 Meters)
Batt Cable 218-Y / H03VV-F PVC FLEXIBLE CABLE | MOQ (500 Meters)
Availability: In Stock

CONDUCTOR : Plain Copper STRANDING : Class 5 INSULATION : PVC OUTERSHEATH : PVC

OUTERSHEATH COLOUR : Black, White RATED VOLTAGE : 300V


CORE IDENTIFICATION

2 core: Blue, Brown

3 core: Green/Yellow, Blue, Brown

4 core: Green/Yellow, Grey, Brown, Black


MINIMUM BENDING RADIUS : 6 x Overall Diameter

OPERATING TEMPERATURE : 70°C

STANDARDS : BS EN 50525-2-11



BATT Part No. Black

BATT Part No. White

No. cores

Nominal cross sectional area of conductor

Radial thickness of insulation

Nominal thickness of oversheath

Approx overall diameter

Weight

37267

37212

2

0.50

0.5

0.6

5.3

37

37392

37165

2

0.75

0.5

0.6

5.6

45

37364

37076

3

0.50

0.5

0.6

5.6

43

37393

37231

3

0.75

0.5

0.6

6.0

54

37789

37789

4

0.50

0.5

0.6

6.2

53

-

37568

4

0.75

0.5

0.6

6.5

68


Batt Part No.

Core

Size

Colour/Reference

37267

2

0.50

Black

37212

2

0.50

White

37392

2

0.75

Black

37165

2

0.75

White

37364

3

0.50

Black

37076

3

0.50

White

37393

3

0.75

Black

37231

3

0.75

White

37789

4

0.50

Black

37789

4

0.50

White

37568

4

0.75

White




  • New
Batt Cable 219-Y / H03VVH2-F PVC FLEXIBLE CABLE | MOQ (500 Meters) Batt Cable 219-Y / H03VVH2-F PVC FLEXIBLE CABLE | MOQ (500 Meters)
Batt Cable 219-Y / H03VVH2-F PVC FLEXIBLE CABLE | MOQ (500 Meters)
Availability: In Stock

CONDUCTOR : Plain Copper STRANDING : Class 5 INSULATION : PVC

OUTERSHEATH : PVC OUTERSHEATH COLOUR : Black, White


RATED VOLTAGE : 300V


CORE IDENTIFICATION

Blue, Brown


MINIMUM BENDING RADIUS

Flexed 8 x overall diameter


OPERATING TEMPERATURE

+5°C to +70°C


STANDARDS

EN 50525-2-11, EN 60228 Flame Retardant according to IEC/EN 60332-1-2



BATT Part No White

BATT Part No Black

Nominal cross sectional area of conductor

Radial thickness of insulation

Nominal thickness of oversheath

Approx overall diameter

Weight

37281

37282

0.5

0.5

0.6

3.35 x 5

30

37228

37196

0.75

0.5

0.6

3.35 x 5.5

37


Batt Part No.

Core

Size

Colour/Reference

37281

2

0.5

White

37282

2

0.5

Black

37228

2

0.75

White

37196

2

0.75

Black


  • New
Batt Cable 309-Y / H05V2V2-F PVC FLEXIBLE CABLE | MOQ (500 Meters) Batt Cable 309-Y / H05V2V2-F PVC FLEXIBLE CABLE | MOQ (500 Meters)
Batt Cable 309-Y / H05V2V2-F PVC FLEXIBLE CABLE | MOQ (500 Meters)
Availability: In Stock

CONDUCTOR : Plain Copper STRANDING : Class 5 INSULATION : PVC

OUTERSHEATH : PVC OUTERSHEATH COLOUR : White


RATED VOLTAGE : 500V


CORE IDENTIFICATION

2 Core: Blue, Brown

3 Core: Green/Yellow, Blue, Brown

4 Core: Green/Yellow, Brown, Black, Grey

5 Core: Green/Yellow, Brown, Black, Grey, Blue


MINIMUM BENDING RADIUS

Overall Bending Radius 6x


OPERATING TEMPERATURE

90°C


STANDARDS

EN 50525-2-11, ROHS 2011/65/UE, EN50575:2014 + A1



DIMENSIONS

BATT Part No

Cores

Nominal cross sectional area of conductor

Radial thickness of insulation

Nominal thickness of oversheath

Approx overall diameter

Weight

43533

2

0.75

0.6

0.8

6.2

55

43535

3

0.75

0.6

0.8

6.6

66

43357

3

1

0.6

0.8

7

78

43031

3

1.5

0.7

0.9

8.2

107

43086

3

2.5

0.8

1.1

10

164

43539

4

0.75

0.6

0.8

7.2

81

43704

4

1

0.6

0.9

7.8

98

43552

4

1.5

0.7

1

9.3

140

43342

4

2.5

0.8

1.1

10.9

202

43360

5

0.75

0.6

0.9

8

100

43553

5

1

0.6

0.9

8.6

120

43543

5

1.5

0.7

0.9

10.3

172


Batt Part No.

Core

Size

Colour/Reference

43312

2

0.5

White

43533

2

0.75

White

43313

2

1

White

43314

2

1.5

White

43315

2

2.5

White

43080

3

0.5

White

43535

3

0.75

White

43357

3

1

White

43031

3

1.5

White

43086

3

2.5

White

43338

4

0.5

White

43539

4

0.75

White

43704

4

1

White-

43552

4

1.5

White

43342

4

2.5

White

43359

5

0.5

White

43360

5

0.75

White

43553

5

1

White

43643

5

1.5

White

43364

5

2.5

White


  • New
Batt Cable 318-AG / ARCTIC GRADE CABLE | MOQ (500 Meters) Batt Cable 318-AG / ARCTIC GRADE CABLE | MOQ (500 Meters)
Batt Cable 318-AG / ARCTIC GRADE CABLE | MOQ (500 Meters)
Availability: In Stock

CONDUCTOR : Plain Copper STRANDING : Class 5 INSULATION : PVC

OUTERSHEATH : PVC OUTERSHEATH COLOUR : Blue, Orange, Yellow


RATED VOLTAGE

500V


CORE IDENTIFICATION

2 Core: Blue, Brown

3 Core: Blue, Brown, Green/Yellow


MINIMUM BENDING RADIUS

3 x Overall Bending Radius


OPERATING TEMPERATURE

70°C


STANDARDS

BS6004, EN 60228 Flame Retardant according to IEC/EN 60332-1-2



Part No

Cores

Nominal cross sectional area of conductor mm2

Nominal thickness of insulation mm2

Nominal thickness of oversheath mm2

Approx overall diameter mm2

Weight kg/km

37680

2

1.5

 

 

7.5

80

37788

3

0.75

 

 

6.7

60

37580

3

1

 

 

7

72

37344

3

1.5

 

 

8.2

98

37134

3

2.5

 

 

10.1

155

37104

3

4

 

 

11.4

215

37682

3

6

 

 

11.10

-

37683

4

1.5

 

 

9

145

37744

4

2.5

 

 

10.7

195

37745

4

6

 

 

14.5

390

37701

5

1.5

 

 

10.2

156


Batt Part No.

Core

Size

Colour/Reference

37680

2

1.5

Yellow

37679

2

1.5

Blue

37788

3

0.75

Yellow

37218

3

0.75

Blue

37580

3

1

Yellow

37344

3

15

Yellow

37237

3

1.5

Blue

37724

3

1.5

Orange

37134

3

2.5

Yellow

37235

3

2.5

Blue

37104

3

4

Yellow

37207

3

4

Blue

37682

3

6

Yellow

37683

4

1.5

Yellow

37725

4

1.5

Blue

37744

4

2.5

Yellow

37767

4

2.5

Blue

37745

4

6

Yellow

37701

5

1.5

Yellow

37684

7

1.5

Yellow


  • New
Batt Cable 318-B / H05Z1Z1-K LSZH FLEXIBLE CABLE | MOQ (500 Meters) Batt Cable 318-B / H05Z1Z1-K LSZH FLEXIBLE CABLE | MOQ (500 Meters)
Batt Cable 318-B / H05Z1Z1-K LSZH FLEXIBLE CABLE | MOQ (500 Meters)
Availability: In Stock

CONDUCTOR : Plain Copper STRANDING : Class 5 OUTERSHEATH : LSZH

OUTERSHEATH COLOUR : Black, White

RATED VOLTAGE

500V


CORE IDENTIFICATION

2 core: Blue Brown

3 core: Green/Yellow Blue Brown

4 core: Green/Yellow Brown Black Grey

5 core: Green/Yellow Brown Black Grey Blue


MINIMUM BENDING RADIUS

Overall Bending Radius 5x


OPERATING TEMPERATURE

70°C


STANDARDS

50525-3-11, EN 50363-7, EN50363-8, EN 50575:2014 + A1



BATT Part No

Cores

Nominal cross sectional area of conductor

Radial thickness of insulation

Approx overall diameter

Weight

45342

2

0.75

0.6

6.3

60

45343

2

1

0.6

6.7

70

45373

2

1.5

0.7

7.6

84

45388

2

2.5

0.8

8.7

135

45489

2

4

0.8

10

190

45305

3

0.75

0.6

6.7

71

45219

3

1

0.6

7.1

82

45357

3

1.5

0.7

8.3

110

45398

3

2.5

0.8

9.5

165

45351

3

4

0.8

10.8

240

45589

3

6

-

12.7

299

45638

3

10

-

16.4

475

45592

3

16

-

18.1

740

45466

4

0.75

0.6

7.2

79

45465

4

1

0.6

7.9

105

45464

4

1.5

0.7

9.3

135

45471

4

2.5

0.8

10.4

200

45487

4

4

0.8

12

290

45639

4

6

-

15

290

45640

4

10

-

12

290

45641

4

16

-

12

290

45444

5

0.75

0.6

8.2

100

45446

5

1

0.6

8.6

130

45448

5

1.5

0.7

10.1

170

45450

5

2.5

0.7

10.8

260

45582

5

4

0.8

14

326

45642

5

6

-

14

326

45643

5

10

-

19.4

821

45644

5

16

-

22.7

1176

45672

6

1

-

9.5

144

45803

7

1

-

9.7

180

45804

7

1.5

-

11.3

245

45646

7

2.5

-

12.7

350

45647

7

4

-

12.7

350

45396

12

0.75

-

12.2

232.8

45648

12

1

-

12.3

300

45649

12

1.5

-

15

390


Batt Part No.

Core

Size

Colour/Reference

45341

2

0.75

Black

45342

2

0.75

White

45564

2

0.75

Grey

45385

2

1

Black

45343

2

1

White

45565

2

1

Grey

45372

2

1.5

Black

45373

2

1.5

White

45566

2

1.5

Grey

45144

2

2.5

Black

45388

2

2.5

White

45567

2

2.5

Grey

45489

2

4

White

45392

2

4

Black

45344

3

0.75

Black

45305

3

0.75

White

45568

3

0.75

Grey

45389

3

1

Black

45219

3

1

White

45569

3

1

Grey

45378

3

1.5

Black

45357

3

1.5

White

45570

3

1.5

Grey

45335

3

2.5

Black

45398

3

2.5

White

45571

3

2.5

Grey

45397

3

4

Black

45351

3

4

White

45588

3

4

Grey

45589

3

6

Grey

45592

3

16

Grey

45500

4

0.75

Black

45466

4

0.75

White

45572

4

0.5

Grey

45472

4

1

Black

45465

4

1

White

45573

4

1

Grey

45464

4

1.5

White

45473

4

1.5

Black

45574

4

1.5

Grey

45499

4

2.5

Black

45471

4

2.5

White

45575

4

2.5

Grey

45467

4

4

Black

45487

4

4

White

45590

4

4

Grey

45443

5

0.75

Black

45444

5

0.75

White

45576

5

0.75

Grey

45445

5

1

Black

45446

5

1

White

45577

5

1

Grey

45447

5

1.5

Black

45448

5

1.5

White

45578

5

1.5

Grey

45449

5

2.5

Black

45450

5

2.5

White

45579

5

2.5

Grey

45582

5

4

Grey

45390

7

0.75

Black

45387

7

1

Black

45380

7

1.5

Black

45382

7

2.5

Black

45396

12

0.75

Black

45399

12

1

Black

45383

12

1.5

Black

45381

12

2.5

Black

45517

25

1

Black

45475

27

1.5

Black

45516

27

2.5

Black

45469

50

1.5

Black


  • New
Batt Cable 318-Y / H05VV-F PVC FLEXIBLE CABLE | MOQ (500 Meters) Batt Cable 318-Y / H05VV-F PVC FLEXIBLE CABLE | MOQ (500 Meters)
Batt Cable 318-Y / H05VV-F PVC FLEXIBLE CABLE | MOQ (500 Meters)
Availability: In Stock

CONDUCTOR : Plain Copper STRANDING : Class 5 INSULATION : PVC

OUTERSHEATH : PVC OUTERSHEATH COLOUR : Black, White, Orange


RATED VOLTAGE

300/500V


CORE IDENTIFICATION

2 core: Brown & Blue

3 core: Brown, Blue & Green/Yellow

4 core: Brown, Grey, Black & Green/Yellow

5 core: Brown, Blue, Grey, Black & Green/Yellow


MINIMUM BENDING RADIUS

6 x Overall Diameter


OPERATING TEMPERATURE

60°C


STANDARDS

H05VV-F BS EN 50525-2-11



BATT Part No. Black

BATT Part No. White

BATT Part No. Orange

No. cores

Nominal cross sectional area of conductor

Nominal thickness of insulation

Approx overall diameter

Weight

37288

37289

37290

2

0.75

0.6

6.3

57

37293

37295

-

2

1

0.6

6.6

65

37299

37300

37481

2

1.5

0.7

7.4

84

37304

37305

-

2

2.5

0.8

7.5

130

37308

37309

-

2

4

0.8

9.3

200

37325

37327

37323

3

0.75

0.6

6.7

68

37334

37335

37616

3

1

0.6

7

78

37341

37342

37617

3

1.5

0.7

8.1

108

37346

37347

37615

3

2.5

0.8

9.9

163

37350

37351

-

3

4

0.8

11.3

227

37567

37550

-

4

0.75

0.6

7.3

82

37556

37531

-

4

1

0.6

7.9

100

-

37554

-

4

1.5

0.7

9

134

37547

37551

-

4

2.5

0.8

10.8

201

37575

-

-

4

4

0.8

12.1

250

37628

37559

-

5

0.75

0.6

8.1

102

-

37563

-

5

1

0.6

8.6

120

37608

37560

-

5

1.5

0.7

10

166

37611

37561

-

5

2.5

0.8

12.5

265


Batt Part No.

Core

Size

Colour/Reference

37288

2

0.75

Black

37289

2

0.75

White

37290

2

0.75

Orange

37293

2

1

Black

37295

2

1

White

37299

2

1.5

Black

37300

2

1.5

White

37481

2

1.5

Orange

37304

2

2.5

Black

37305

2

2.5

White

37308

2

4

Black

37309

2

4

White

37325

3

0.75

Black

37327

3

0.75

White

37323

3

0.75

Orange

37334

3

1

Black

37335

3

1

White

37616

3

1

Orange

37341

3

1.5

Black

37342

3

1.5

White

37617

3

1.5

Orange

37346

3

2.5

Black

37347

3

2.5

White

37615

3

2.5

Orange

37350

3

4

Black

37351

3

4

White

37567

4

0.75

Black

37550

4

0.75

White

37556

4

1

Black

37531

4

1

White

37554

4

1.5

White

37547

4

2.5

Black

37551

4

2.5

White

37575

4

4

Black

37628

5

0.75

Black

37559

5

0.75

White

37563

5

1

White

37608

5

1.5

Black

37560

5

1.5

White

37611

5

2.5

Black

37561

5

2.5

White


  • New
Batt Cable 2491-B / 6701-B LSZH SINGLE CORE FLEXIBLE CABLE H05Z-K 300/500V | MOQ (500 Meters) Batt Cable 2491-B / 6701-B LSZH SINGLE CORE FLEXIBLE CABLE H05Z-K 300/500V | MOQ (500 Meters)
Batt Cable 2491-B / 6701-B LSZH SINGLE CORE FLEXIBLE CABLE H05Z-K 300/500V | MOQ (500 Meters)
Availability: In Stock

CONDUCTOR : Plain Copper STRANDING : Class 5 OUTERSHEATH : LSZH

OUTERSHEATH COLOUR

Black, White, Blue, Grey, Violet, Orange, Red, Green/Yellow, Brown, Pink, Yellow, Green

RATED VOLTAGE : 300/500V


MINIMUM BENDING RADIUS

Up to 35mm2: 4 x overall diameter 50mm2 and above: 6 x overall diameter


OPERATING TEMPERATURE

Maximum 90°C, Minimum bending -15°C


STANDARDS

BS7211 BSEN50267-1 BSEN50266-1



Nominal cross sectional area of conductor sqmm

Nominal thickness of insulation

Nomina overall diameter lower limit

Nominal overall diameter upper limit

Weight kg/km

0.5

0.6

2.1

2.6

8.7

0.75

0.6

2.2

2.8

11.3

1

0.6

2.4

2.9

13.9


Core

Size

Red

Black

Green/Yellow

Blue (5015)

Yellow

Brown

Violet

Pink

White

Orange

Grey

Green

1

0.5

45222

45102

45108

45225

45226

45227

45228

45174

45105

45231

45763

45173

1

0.75

45124

45097

45138

45140

45137

45139

45159

45158

45155

45156

45141

45157

1

1.0

45063

45064

45065

45067

45068

45066

45216

45235

45217

45236

45142

45237


  • New
Batt Cable 2491-B / 6701-B LSZH SINGLE CORE FLEXIBLE CABLE H07Z-K | MOQ (500 Meters) Batt Cable 2491-B / 6701-B LSZH SINGLE CORE FLEXIBLE CABLE H07Z-K | MOQ (500 Meters)
Batt Cable 2491-B / 6701-B LSZH SINGLE CORE FLEXIBLE CABLE H07Z-K | MOQ (500 Meters)
Availability: In Stock

CONDUCTOR : Plain Copper STRANDING : Class 5 OUTERSHEATH : LSZH

OUTERSHEATH COLOUR

Black, White, Blue, Grey, Violet, Orange, Red, Green/Yellow, Pink, Yellow, Green


RATED VOLTAGE : 750V


MINIMUM BENDING RADIUS

Up to 35mm2: 4 x overall diameter 50mm2 and above: 6 x overall diameter


OPERATING TEMPERATURE

Maximum 90°C, Minimum bending -15°C


STANDARDS

BS EN 50525-3-41



Nominal cross sectional area of conductor sqmm

Nominal thickness of insulation 

Nominal overall diameter lower limit

Nominal overall diameter upper limit

Weight kg/km

1.5

0.7

2.8

3.5

19.3

2.5

0.8

3.4

4.3

30.9

4

0.8

3.9

4.9

44.9

6

0.8

4.4

5.5

64.2

10

1

5.7

7.1

108.2

16

1

6.7

8.4

163.4

25

1.2

8.4

10.6

248.1

35

1.2

9.7

12.1

340.6

50

1.4

11.5

14.4

484.2

70

1.4

13.2

16.6

671

95

1.6

15.1

18.8

895.8

120

1.6

16.7

20.9

1111.1

150

1.8

18.6

23.3

1389.2

185

2

20.6

25.8

1724.1

240

2.2

23.5

29.4

2225.4


Core

Size

Red

Black

Green/Yellow

Blue (5015)

Yellow

Brown

Violet

Pink

White

Orange

Grey

Green

1

1.5

45069

45147

45071

45073

45074

45072

45239

45238

45240

45171

45115

45241

1

2.5

45075

45076

45077

45079

45080

45078

45242

45243

45244

45185

45116

45176

1

4

45081

45082

45083

45085

45086

45084

45247

45248

45249

45187

45117

45251

1

6

45087

45088

45089

45091

45092

45090

 

 

45531

 

45118

 

1

10

45252

45209

45253

45483

45143

45483

 

 

45135

 

45555

 

1

16

45254

45210

45255

45492

45153

45556

 

 

45152

 

45557

 

1

25

 

45211

45495

45494

 

45616

 

 

 

 

45617

 

1

35

 

45393

45485

45486

 

45618

 

 

 

 

45619

 

1

50

 

45585

45541

45480

 

45474

 

 

 

 

45476

 

1

70

 

45584

45542

 

 

 

 

 

 

 

 

 

1

95

 

45594

45543

 

 

 

 

 

 

 

 

 

1

120

 

45769

45544

 

 

 

 

 

 

 

 

 

1

150

 

45768

45545

 

 

 

 

 

 

 

 

 

1

185

 

45766

45767

 

 

 

 

 

 

 

 

 

1

240

 

45809

45730

 

 

 

 

 

 

 

 

 


  • New
Batt Cable 2491-X PVC SINGLE CORE FLEXIBLE CABLE H05V-K | MOQ (500 Meters) Batt Cable 2491-X PVC SINGLE CORE FLEXIBLE CABLE H05V-K | MOQ (500 Meters)
Batt Cable 2491-X PVC SINGLE CORE FLEXIBLE CABLE H05V-K | MOQ (500 Meters)
Availability: In Stock

CONDUCTOR : Plain Copper


STRANDING : Class 5


OUTERSHEATH : PVC


OUTERSHEATH COLOUR

Black, White, Blue, Grey, Violet, Orange, Red, Green/Yellow, Brown, Pink, Yellow, Green


RATED VOLTAGE

300/500V


MINIMUM BENDING RADIUS

Fixed: 6 x overall diameter


OPERATING TEMPERATURE

Maximum 70°C, Minimum bending 0°C


STANDARDS

BS EN 50525-2-31



Nominal cross sectional area of conductor sqmm

RT on insulation mm

Approx conductor diameter mm

Nominal overall diameter mm

Weight kg/km

Approx overall diameter

Electrical resistance at 20°C OHM/KM

Insulation resistance min at 70°C OHM/KM

Current carrying capacity at 30°C in air or pipe

0.5

 

 

 

9.1

2.20

39

 

 

0.75

 

 

 

11.7

2.40

26

 

 

1.0

 

 

 

14.4

2.55

19.5

 

 


Core

Size

Red

Black

Green/Yellow

Blue 

Yellow

Brown

Violet

Pink

White

Orange

Grey 

Green 

1

0.5

37003

37004

37014

37005

37007

37006

37010

37011

37009

37012

37008

37013

1

0.75

37487

37016

37027

37490

37020

37019

37655

 

37018

37023

37021

37026

1

1.0

37028

37029

37040

37731

37034

37031

37037

 

37030

37036

37032

37039


  • New
Batt Cable 2491-X PVC SINGLE CORE FLEXIBLE CABLE H07V-K 450/750V | MOQ (500 Meters) Batt Cable 2491-X PVC SINGLE CORE FLEXIBLE CABLE H07V-K 450/750V | MOQ (500 Meters)
Batt Cable 2491-X PVC SINGLE CORE FLEXIBLE CABLE H07V-K 450/750V | MOQ (500 Meters)
Availability: In Stock

CONDUCTOR : Plain Copper STRANDING : Class 5 OUTERSHEATH : PVC


OUTERSHEATH COLOUR

Black, White, Blue, Grey, Violet, Orange, Red, Green/Yellow, Brown, Pink, Yellow, Green


RATED VOLTAGE : 750V


MINIMUM BENDING RADIUS : Fixed: 6 x overall diameter


OPERATING TEMPERATURE

Maximum 70°C, Minimum bending 0°C


STANDARDS

BS EN 50525-2-31



Nominal cross sectional area of conductor sqmm

RT on insulation mm

Aprrox conductor diameter mm

Nominal overall diameter mm

Weight kg/km

Electrical resistance at 20°C OHM/KM

Insulation resistance min at 70°C OHM/KM

Current carrying capacity at 30°C in air or pipe

1.5

0.7

1.3

3.1

21

13.3

0.01

15.5

2.5

0.8

2.0

3.75

33

7.98

0.009

21

4

0.8

2.6

4.4

48

4.95

0.007

28

6

0.8

3.4

4.9

66

3.3

0.006

36

10

1.0

4.4

6.4

112

1.91

0.0056

50

16

1.0

5.7

7.4

167

1.21

0.0046

68

25

1.2

6.9

9.1

254

0.78

0.0044

89

35

1.2

8.1

10.35

340

0.554

0.0038

110

50

1.4

9.8

12.4

485

0.386

0.0037

154

70

1.4

11.6

13.6

674

0.272

0.0032

171

95

1.6

13.3

15.8

894

0.206

0.0032

207

120

1.8

15.1

17.4

1110

0.161

0.0029

239


Core

Size

Red

Black

Green/Yellow

Blue (5015)

Yellow

Brown

Violet

Pink

White

Orange

Grey

Green

1

1.5

37493

37495

37496

37497

37047

37494

37050

37048

37045

37049

37046

37051

1

2.5

37053

37234

37065

37247

37058

37250

37062

37055

37060

37061

37059

37051

1

4

37066

37067

37073

37360

37071

37366

 

 

37071

 

 

37072

1

6

37498

37398

37380

37400

37107

37402

 

 

37644

 

37103

 

1

10

37499

37403

37106

37406

37120

37407

 

 

37112

 

37108

 

1

16

37131

37408

37154

 

37155

37092

 

 

37136

 

37130

 

1

25

 

37416

37174

 

 

 

 

 

 

 

 

 

1

35

37515

37418

37175

37516

 

37740

 

 

 

 

 

 

1

50

37594

37210

37203

 

 

 

 

 

 

 

 

 

1

70

 

37219

37641

 

 

 

 

 

 

 

 

 

1

95

 

37453

37489

 

 

 

 

 

 

 

 

 


  • New
Batt Cable 6381-B LSZH FLEXIBLE DC POWER CABLE BS7211 450/750V | MOQ (500 Meters) Batt Cable 6381-B LSZH FLEXIBLE DC POWER CABLE BS7211 450/750V | MOQ (500 Meters)
Batt Cable 6381-B LSZH FLEXIBLE DC POWER CABLE BS7211 450/750V | MOQ (500 Meters)
Availability: In Stock

CONDUCTOR : Plain Copper STRANDING : Class 5 INSULATION : XLPE

OUTERSHEATH : LSZH OUTERSHEATH COLOUR : Blue, Grey


RATED VOLTAGE

450/750v


MINIMUM BENDING RADIUS

Up to 50mm2: 3 x overall diameter 70mm2 and above: 4 x overall diameter


OPERATING TEMPERATURE

Fixed: 0°C to +90°C


STANDARDS

BS 7211, IEC 60502-1, EN 60228 Flame Retardant according to IEC/EN 60332-1-2



BATT Part No

Sheath Colour

Nominal cross sectional area of conductor

Radial thickness of insulation

Nominal thickness off extruded bedding

Nominal steel armour wire diameter

Nominal thickness of oversheath

Approx overall diameter

Weight

45633

Blue

16

0.7

 

 

 

8.4

177

45634

Grey

16

0.7

 

 

 

8.4

177

45635

Blue

25

0.9

 

 

 

10.3

266

45636

Grey

25

0.9

 

 

 

10.3

266

45796

Grey

35

0.9

 

 

 

11.5

365

45797

Blue

35

0.9

 

 

 

11.5

365


Batt Part No.

Core

Size

Colour/Reference

45633

1

16

Blue/Blue

45634

1

16

Grey/Grey

45635

1

25

Blue/Blue

45636

1

25

Grey/Grey

45797

1

35

Blue/Blue

45796

1

35

Grey/Grey


  • New
Batt Cable 6381-Y PVC FLEXIBLE DC POWER CABLE BS6004  | MOQ (500 Meters) Batt Cable 6381-Y PVC FLEXIBLE DC POWER CABLE BS6004  | MOQ (500 Meters)
Batt Cable 6381-Y PVC FLEXIBLE DC POWER CABLE BS6004 | MOQ (500 Meters)
Availability: In Stock

CONDUCTOR : Plain Copper STRANDING: Class 5 INSULATION: PVC


OUTERSHEATH: PVC


OUTERSHEATH COLOUR: Black, White, Blue, Grey, Brown


RATED VOLTAGE : 0.6/1kV


MINIMUM BENDING RADIUS

Up to 50mm²: 3 x overall diameter Above 70mm²: 4 x overall diameter


OPERATING TEMPERATURE

Maximum 70°C, Minimum bending -15°C


STANDARDS

BS 6004, IEC 60502-1, EN 60228 Flame Retardant according to IEC/EN 60332-1-2 BS6004 is only up to 35sqmm and 50sqmm> is IEC60502



Core

Size

BATT Part No Black

BATT Part No Grey

BATT Part No brown

BATT Part No Blue

1

2.5

 

37763

37828

37762

1

4

 

37765

37829

37764

1

6

37518

37636

37830

37517

1

10

37449

37638

37831

37450

1

16

37465

37634

37832

37461

1

25

37468

37602

37833

37469

1

35

37514

37603

37834

37513

1

50

37691

37692

37835

37690

1

70

 

37248

37836

37193

1

95

37077

37396

37837

37088

1

120

 

37253

 

37209

1

150

 

37646

 

37645

1

185

37126

37604

 

37197

1

240

 

37722

 

37721


BATT Part No Black

BATT Part No Grey

BATT Part No Brown

BATT Part No Blue

Nominal cross sectional area of conductor

Diameter of conductor

Radial thickness of insulation

Thickness of oversheath mm

Approx overall diameter

Weight

 

37763

37828

37762

2.5

 

 

 

 

 

 

37765

37829

37764

4

2.50

1.0

1.2

6.9

82

37518

37636

37830

37517

6

3.00

1.0

1.2

7.4

104

37449

37638

37831

37450

10

4.10

1.2

1.2

8.9

157

37465

37634

37832

37461

16

5.25

1.2

1.2

10.1

220

37468

37602

37833

37469

25

6.60

1.4

1.4

12.2

329

37514

37603

37834

37513

35

7.74

1.4

1.4

13.4

431

37691

37692

37835

37690

50

9.25

1.4

1.4

14.9

575

 

37248

37863

37193

70

11.0

1.4

1.4

16.6

764

37077

37396

37837

37088

95

13.1

1.6

1.6

19.5

1033

 

37253

 

37209

120

14.2

1.6

1.6

20.6

1265

 

37646

 

37645

150

15.8

1.8

1.8

23.0

1572

37126

37604

 

37197

185

18.6

2.0

1.8

26.2

1931

 

37722

 

37721

240

21.0

2.2

1.8

29.0

2471

 

 

 

 

300

23.0

2.4

2.0

31.8

3068

 

 

 

 

400

30.0

2.6

2.0

39.2

4149


  • New
Batt Cable TRI RATED BS6231 FLEXIBLE PVC CABLE | MOQ (500 Meters) Batt Cable TRI RATED BS6231 FLEXIBLE PVC CABLE | MOQ (500 Meters)
Batt Cable TRI RATED BS6231 FLEXIBLE PVC CABLE | MOQ (500 Meters)
Availability: In Stock


CONDUCTOR: Plain Copper , STRANDING: Class 5  ,INSULATION : PVC


OUTERSHEATH COLOUR:

Black, White, Blue, Grey, Violet, Orange, Red, Green/Yellow, Brown, Pink, Yellow, Green


RATED VOLTAGE : 0.6/1kV


CORE IDENTIFICATION : 1 Core


MINIMUM BENDING RADIUS:: Overall Bending Radius 6x


OPERATING TEMPERATURE : 105°C


STANDARDS : UL/CSA & BS6231




Batt Part No.

Core

Size

Colour/Reference

38001

1

0.5

Red

38003

1

0.5

Black

38008

1

0.5

Green/Yellow

38005

1

0.5

Blue

38032

1

0.5

Yellow

38009

1

0.5

Brown

38035

1

0.5

Violet

38037

1

0.5

Pink

38010

1

0.5

White

38040

1

0.5

Orange

38006

1

0.5

Grey

38043

1

0.5

Green

38012

1

0.75

Red

38013

1

0.75

Black

38021

1

0.75

Green/Yellow

38026

1

0.75

Blue

38016

1

0.75

Yellow

38022

1

0.75

Brown

38023

1

0.75

Violet

38025

1

0.75

Pink

38019

1

0.75

White

38024

1

0.75

Orange

38015

1

0.75

Grey

38020

1

0.75

Green

38028

1

1

Red

38031

1

1

Black

38046

1

1

Green/Yellow

38033

1

1

Blue

38039

1

1

Yellow

38036

1

1

Brown

38130

1

1

Violet

38048

1

1

Pink

38042

1

1

White

38047

1

1

Orange

38034

1

1

Grey

38227

1

1

Green

38051

1

1.5

Red

38052

1

1.5

Black

38065

1

1.5

Green/Yellow

38056

1

1.5

Blue

38057

1

1.5

Yellow

38054

1

1.5

Brown

38061

1

1.5

Violet

38060

1

1.5

Pink

38058

1

1.5

White

38062

1

1.5

Orange

38059

1

1.5

Grey

38063

1

1.5

Green

38079

1

2.5

Red

38081

1

2.5

Black

38096

1

2.5

Green/Yellow

38085

1

2.5

Blue

38088

1

2.5

Yellow

38083

1

2.5

Brown

38091

1

2.5

Violet

38097

1

2.5

Pink

38090

1

2.5

White

38092

1

2.5

Orange

38089

1

2.5

Grey

38093

1

2.5

Green

38100

1

4

Red

38102

1

4

Black

38114

1

4

Green/Yellow

38106

1

4

Blue

38108

1

4

Yellow

38104

1

4

Brown

38105

1

4

Violet

38117

1

4

Pink

38109

1

4

White

38116

1

4

Orange

38110

1

4

Grey

38112

1

4

Green

38122

1

6

Red

38124

1

6

Black

38136

1

6

Green/Yellow

38134

1

6

Blue

38132

1

6

Yellow

38129

1

6

Brown

38135

1

6

Violet

38211

1

6

Pink

38126

1

6

White

38011

1

6

Orange

38128

1

6

Grey

38087

1

6

Green

38140

1

10

Red

38141

1

10

Black

38153

1

10

Green/Yellow

38145

1

10

Blue

38146

1

10

Yellow

38143

1

10

Brown

38139

1

10

Violet

38165

1

10

Pink

38154

1

10

White

38166

1

10

Orange

38148

1

10

Grey

38150

1

10

Green 

38157

1

16

Red

38160

1

16

Black

38167

1

16

Green/Yellow

38164

1

16

Blue

38161

1

16

Yellow

38169

1

16

Brown

38041

1

16

White

38159

1

16

Grey

38168

1

16

Green

38173

1

25

Red

38176

1

25

Black

38184

1

25

Green/Yellow

38185

1

25

Blue

38179

1

25

Yellow

38177

1

25

Brown

38045

1

25

White

38225

1

25

Grey

38182

1

25

Green

38188

1

35

Red

38189

1

35

Black

38192

1

35

Green/Yellow

38191

1

35

Blue

38190

1

35

Yellow

38038

1

35

Brown

38050

1

35

White

38193

1

50

Red

38194

1

50

Black

38196

1

50

Green/Yellow

38195

1

50

Blue

38068

1

50

Yellow

38069

1

50

Brown

38197

1

70

Red

38053

1

50

White

38198

1

70

Black

38200

1

70

Green/Yellow

38082

1

70

Brown

38201

1

70

Blue

38202

1

95

Red

38205

1

95

Black

38127

1

95

Green/Yellow

38002

1

95

Blue

38208

1

120

Red

38207

1

120

Black

38055

1

120

Green/Yellow

38095

1

120

Blue

38172

1

150

Red

38000

1

150

Black

38174

1

150

Green/Yellow

38175

1

185

Red

38178

1

185

Black

38180

1

185

Green/Yellow

38181

1

240

Red

38158

1

240

Black

38144

1

240

Green.Yellow

38187

1

300

Red

38199

1

300

Black

38203

1

300

Green/Yellow

38070

1

35

Grey

38032

1

0.5

Yellow

38121

1

400

Black

38107

1

95

Brown

38111

1

120

Brown

38183

1

240

Black

38072

1

50

Grey

38075

1

70

Grey

38080

1

95

Grey

38113

1

120

Grey

38133

1

10

Green

38118

1

70

Yellow


Where cables are to be grouped, the following factors should be applied

No. of cables in grou

2

3

4

5

6

7

8

Re-Rating Factor

0.80

0.70

0.65

0.60

0.56

0.53

0.50

 

DE-RATING FACTORS

De-Rating Factor for Ambient Temperature 60ºC Thermoplastic or Thermosetting Insulated Cords

Air Temperature

45°C

50°C

55°C

60°C

65°C

70°C

75°C

De-Rating Factor

1

0.97

0.90

0.82

0.73

0.63

0.52

ELECTRICAL CHARACTERISTICS

Current Carrying Capacity and Voltage Drop

Nominal Cross Sectional Area mm2

Current Rating (Peak) Amps

Voltage Drop mV/A/m

0.5

11

46

0.75

14

31

1

17

22

1.5

21

15

2.5

30

9.1

4

41

5.7

6

53

3.8

10

75

2.2

16

100

14

25

136

0.89

35

167

0.64

50

204

0.45

70

259

0.32

95

321

0.24

120

374

0.19

150

429

0.16

185

496

0.13

240

595

0.1

 

CONDUCTORS 

Class 5 Flexible Copper Conductors for Single Core and Multi Core Cables

Nomial Cross Sectional Area mm2

Maximum Diameter of Wires on Conductor mm

Maximum Resistace of Conductor at 20°C ohms/km Plain Wires

0.5

0.21

39

0.75

0.21

26

1

0.21

19.5

1.5

0.26

13.3

2.5

0.26

7.98

4

0.31

4.95

6

0.31

3.3

10

0.41

1.91

16

0.41

1.21

25

0.41

0.78

35

0.41

0.554

50

0.41

0.386

70

0.51

0.272

95

0.51

0.206

120

0.51

0.161

150

0.51

0.129

185

0.51

0.106

240

0.51

0.0801

COLOUR CODES

Colour

Black

Green

Blue

Light Blue

Dark Blue

Grey

Green/Yellow

Orange

Red

Pink

Yellow

Violet

Brown

White

Code

BK

GN

BL

LTBL

DKBL

GR

GY

OR

RD

PK

YW

VI

BR

WH

DIMENSIONS

BATT Part No

Cores

Nominal cross sectional area of conductor

Approximate

Nominal thickness off insulation

Approx overall diameter

Weight

38003

1

0.5

21

0.8

2.6

12

38013

1

0.75

19

0.8

2.8

15

38031

1

1

18

0.8

3

18

38052

1

1.5

16

0.8

3.3

23

38081

1

2.5

14

0.8

3.8

34

38102

1

4

12

0.8

4.3

50

38124

1

6

10

0.8

4.9

71

38141

1

10

8

1

6.3

123

38160

1

16

6

1

9

207

38176

1

25

4

1.2

10.4

303

38189

1

35

2

1.2

11.9

412

38194

1

50

1

1.4

14.7

607

38198

1

70

2

1.4

16.8

837

38205

1

95

3

1.6

18.8

1080

38207

1

120

4

1.6

20.4

1280

38000

1

150

250 mcm

1.8

20.2

1415

38178

1

185

350 mcm 

2

26

1940

38183

1

240

450 mcm

2.2

29.5

2550

38199

1

300

 

 

32.7

3140

38121

1

400

 

 

36

4051


  • New
Top Quality Electrical Equipment & Supplies | Africa B2B

Discover wholesale electrical equipment & supplies on Africa's top B2B platform. Low MOQ, fast shipping, and competitive prices for reliable sourcing.

busy...