CONDUCTOR: Tinned Copper
STRANDING: Class 2 INSULATION: MGT+EPR
INDIVIDUAL SCREEN: Individual Copper Mylar BEDDING: LSZH
ARMOUR: Tinned Copper Wire Braid OUTERSHEATH: SHF2
OUTERSHEATH COLOUR: Blue, Grey RATED VOLTAGE: 250V
CORE IDENTIFICATION:
Pairs: black, blue and numbered
Triples: black, blue, brown and numbered
OPERATING TEMPERATURE: 90°C
STANDARDS: NEK 606, IEC 60092-353, EN 60228, IEC 60331, IEC 60332-3-22, IEC 60332-1-2, IEC 61034-2, IEC 60754-1/2, EN 60079-14:2013 clause 9.3.2a
Pairs
Triples
Conductors
Electrical Characteristics
CONDUCTOR: Tinned Copper STRANDING: Class 2
INSULATION: EPR INDIVIDUAL SCREEN: Individual Copper Mylar
BEDDING: LSZH ARMOUR: Tinned Copper Wire Braid
OUTERSHEATH: SHF2 OUTERSHEATH COLOUR: Blue, Grey
RATED VOLTAGE: 250V
CORE IDENTIFICATION
Pairs: black, blue
Triples: black, blue, brown
OPERATING TEMPERATURE 90 deg. C
STANDARDS
NEK606, IEC60092-376, IEC60092-376, IEC60332, IEC61031-1.2 IEC60754-1, IEC60228, CSA C 22.2, EN 60079-14:2013 clause 9.3.2a
Triples
Electrical data
CONDUCTOR: Tinned Copper STRANDING: Class 2
INSULATION: EPR BEDDING: LSZH
ARMOUR: Tinned Copper Wire Braid OUTERSHEATH: SHF2
OUTERSHEATH COLOUR: Black RATED VOLTAGE: 0.6/1kV
CORE IDENTIFICATION:
1 core: off-white
2 cores: off-white and black
3 cores: off-white, black and red
4 cores: off-white, black, red and blue
5 cores and above: white and numbered
with a green/yellow core:
3 cores: blue, brown, G/Y
4 cores: black, brown, grey, G/Y
5 cores: black, brown, grey, blue, G/Y
OPERATING TEMPERATURE: 90 deg. C
STANDARDS: NEK 606, IEC60092-353, IEC60754-1/2, IEC60332-3-22, IEC61034-1,2, CSA C 22.2, EN 60079-14:2013 clause 9.3.2a
Electrical data
CONDUCTOR: Plain Copper STRANDING: Class 1
INSULATION: PE OUTERSHEATH: LSZH
OUTERSHEATH COLOUR: Blue, Violet, Red, Green SHIELD: FTP
CORE IDENTIFICATION:
Pair 1: Blue, White/Blue
Pair 2: Orange, White/Orange
Pair 3: Green, White/Green
Pair 4: Brown, White/Brown
MINIMUM BENDING RADIUS: Overall Bending Radius 4x
OPERATING TEMPERATURE: 60°C
STANDARDS: ISO/IEC 11801, TIA 568C.2, YD/T1019 Flame Retardant according to BS EN/IEC 60332-1-2
ELECTRICAL CHARACTERISTICS
PERFORMANCE CHARACTERISTICS
DIMENSIONS
CONDUCTOR: Plain Copper STRANDING: Class 1
INSULATION: PE OUTERSHEATH: PVC
OUTERSHEATH COLOUR: Grey SHIELD: FTP
CORE IDENTIFICATION:
Pair 1: Blue. White/Blue
Pair 2: Orange, White/Orange
Pair 3: Green, White/Green
Pair 4: Brown, White/Brown
MINIMUM BENDING RADIUS: Overall Bending Radius 4x
OPERATING TEMPERATURE: 70°C
STANDARDS: IEC 11801, TIA 568C.2 Flame Retardant according to BS EN/IEC 60332-1-2
ELECTICAL CHARACTERISTICS
PERFORMANCE CHARACTERISTICS
DIMENSIONS
CONDUCTOR : Plain Copper STRANDING: Class 2
INSULATION: PE OUTERSHEATH: LSZH
OUTERSHEATH COLOUR: Violet SHIELD : UTP
CORE IDENTIFICATION:
Pair 1: Blue, White/Blue
Pair 2: Orange. White/Orange
Pair 3: Green, White/Green
Pair 4: Brown, White/Brown
MINIMUM BENDING RADIUS: Overall Bending Radius 8x
OPERATING TEMPERATURE : 60°C
STANDARDS: EN50288-1, EN50288-3-2: patch cord cable, EN50173 ISO/IEC 11801
ELECTRICAL CHARACTERISTICS
PERFORMANCE CHARACTERISTICS
DIMENSIONS
CONDUCTOR: Plain Copper STRANDING: Class 2
INSULATION: PE OUTERSHEATH: PVC
OUTERSHEATH COLOUR: Blue, Grey, Violet, Orange, Green
SHIELD: UTP
CORE IDENTIFICATION:
Pair 1: Blue, White/Blue
Pair 2: Orange, White/Orange
Pair 3: Green, White/Green
Pair 4: Brown, White,Brown
MINIMUM BENDING RADIUS: Overall Bending Radius 4x
OPERATING TEMPERATURE: 70°C
STANDARDS: ISO / IEC 11801, TIA 568C.2 Flame retardant according to BS EN/IEC 60332-1-2
ELECTRICAL CHARACTERISTICS
PERFORMANCE CHARACTERISTICS
DIMENSIONS
CONDUCTOR: Plain Copper STRANDING: Class 1
INSULATION: PE OUTERSHEATH: LSZH
OUTERSHEATH COLOUR: Grey, Violet, Orange SHIELD: UTP
CORE IDENTIFICATION:
Pair 1: Blue, Blue/White
Pair 2: Orange, White/Orange
Pair 3: Green/ White/Green
Pair 4: Brown, White/Brown
MINIMUM BENDING RADIUS: Overall Bending Radius 4x
OPERATING TEMPERATURE: 60°C
STANDARDS: ISO.IEC, TIA 568C.2, YD/T1019 Flame Retardant according to BS EN/IEC 60332-1-2
ELECTRICAL CHARACTERISTICS
PERFORMANCE CHARACTERISTICS
DIMENSIONS
CONDUCTOR: Plain Copper STRANDING: Class 1
INSULATION: PE OUTERSHEATH: PVC
OUTERSHEATH COLOUR: White, Blue, Grey, Red, Yellow, Green SHIELD: UTP
CORE IDENTIFICATION:
Pair 1: Blue, White/Blue
Pair 2: Orange, White Orange
Pair 3: Green, White/Green
Pair 4: Brown, White/Brown
MINIMUM BENDING RADIUS: Overall Bending Radius 4x
OPERATING TEMPERATURE: 70°C
STANDARDS:
ISO / IEC 11801,TIA 568C.2 Flame Retardant according to BS EN/IEC 60332-1-2
ELECTRICAL CHARACTERISTICS
CHARACTERISTICS
DIMENSIONS
CONDUCTOR: Plain Copper STRANDING: Class 1
INSULATION: PE OUTERSHEATH: LSZH
OUTERSHEATH COLOUR: Black, White, Violet, Red SHIELD: UTP
CORE IDENTIFICATION:
Pair 1: Blue, White/Blue
Pair 2: Orange, White/Orange
Pair 3: Green, White/Green
Pair 4: Brown. White/Brown
MINIMUM BENDING RADIUS: Overall Bending Radius 4x
OPERATING TEMPERATURE: 60°C
STANDARDS:
ISO / IEC 11801, TIA 568C.2 Flame Retardant according to BS EN/IEC 60332-1-2
ELECTRICAL CHARACTERISTICS
PERFORMANCE CHARACTERISTICS
DIMENSIONS
CONDUCTOR: Plain Copper STRANDING: Class 1 INSULATION: PE
OUTERSHEATH COLOUR: Black, Grey SHIELD: UTP
CORE IDENTIFICATION:
Pair 1: Blue, White/Blue
Pair 2: Orange, White/Orange
Pair 3: Green, White/Green
Pair 4: Brown, White/Brown
MINIMUM BENDING RADIUS: Overall Bending Radius 4x
OPERATING TEMPERATURE: 60°C
STANDARDS: ISO / IEC 11801, TIA 568C.2, YD/T1019
ELECTRICAL CHARACTERISTICS
PERFORMANCE CHARACTERISTICS
DIMENSIONS
CONDUCTOR: Plain Copper STRANDING: Class 2
INSULATION: MGT+XLPE BEDDING: LSZH
ARMOUR: Steel Wire Armour OUTERSHEATH: LSZH
OUTERSHEATH COLOUR: Black RATED VOLTAGE: 0.6/1kV
CORE IDENTIFICATION:
3 Core: Brown, Black, Grey
4 Core: Brown, Blue, Black, Grey
5 Core: Brown, Blue, Black, Grey, Green/Yellow
MINIMUM BENDING RADIUS: 6 x Overall Diameter OPERATING TEMPERATURE: 90°C
STANDARDS : BS7846 – F120, BS8491 – F120, BS EN 60332-1 BS EN 60332-3 Categories A, B & C, IEC60754, BS EN 50267-2-1:, IEC 61034, BS EN 50268
CONDUCTOR: Plain Copper STRANDING: Class 2
INSULATION: MGT+XLPE BEDDING: LSZH
ARMOUR: Steel Wire Armour OUTERSHEATH: LSZH
OUTERSHEATH COLOUR: Black
CORE IDENTIFICATION:
2 Core: Blue, Brown
3 Core: Brown, Black, Grey
4 Core: Brown, Blue. Black, Grey
5 Core: Brown, Black, Grey, Blue, Green/Yellow
7 Core: White + Black Numbered
12 Core: White + Black Numbered
19 Core: White + Black Numbered
27 Core: White + Black Numbered
37 Core: White + Black Numbered
MINIMUM BENDING RADIUS: 6 x Overall Diameter
OPERATING TEMPERATURE: 90°C
STRANDING: Class 2 INSULATION: XLPE BEDDING: LSZH
ARMOUR: AWA (single core) or SWA (multi core) OUTERSHEATH: LSZH
OUTERSHEATH COLOUR: Black RATED VOLTAGE: 0.6/1kV
CORE IDENTIFICATION:
1 Core - Brown
2 Core - Brown, Blue
3 Core - Brown, Black & Grey (Optional: Brown, Blue & Green/Yellow)
4Core - Brown, Black, Grey & Blue (Optional: Brown, Black, Grey & Green/Yellow)
5 Core - Numbered Cores (Optional: Brown, Black, Grey, Blue + Green/Yellow)
6 Core+ - Numbered Cores (Optional: Numbered + Green/Yellow)
MINIMUM BENDING RADIUS: 1.5sqmm to 16sqmm - 6 x overall diameter (circular cond.) 25sqmm and above - 8 x overall diameter (shaped cond.)
OPERATING TEMPERATURE: Maximum 90°C. Mininum operating -25°C
STANDARDS
BS6724: Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000V and 1900/3300V, having low emission of smoke and corrosive gases when affected by fire BSEN50267-1Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Apparatus BSEN50267-2-1:Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures. Determination of the amount of halogen acid gas BSEN50266-1Common test methods for cables under fire conditions. Test for vertical flame spread of vertically-mounted bunched wires or cables IEC60502: Power cables with extruded insulation and their accessories for rated voltages from 1kV to 30kV BSEN/IEC60332-1-2: Tests on electric and optical fibre cables under fire conditions Part 1: test for vertical flame propagation for a single insulated wire or cable Section 2: procedure for 1kW pre-mixed flame BSEN61034-2:2005 Measurement of smoke density of cables burned under defined conditions. Test procedure and requirements Flame Propagation Test to BS EN 60332-1-2:2004 for single cable and BS EN 60332- 3-24:2009 (Cat C) for multiple cables
CONDUCTOR: Plain Copper STRANDING: Class 2 INSULATION: XLPE
BEDDING: PVC ARMOUR: AWA (single core) or SWA (multi core)
OUTERSHEATH: PVC OUTERSHEATH COLOUR: Black RATED VOLTAGE: 0.6/1kV
CORE IDENTIFICATION:
One Core - Brown
Two Core - Brown, Blue
Three Core - Brown, Black & Grey (Optional: Brown, Blue & Green/Yellow)
Four Core - Brown, Black, Grey & Blue (Optional: Brown, Black, Grey & Green/Yellow)
Five Core - Numbered Cores (Optional: Brown, Black, Grey, Blue & Green/Yellow)
Six Core and Above - Numbered Cores (Optional: Numbered + Green/Yellow)
MINIMUM BENDING RADIUS:
1.5sqmm - 16sqmm - 6x Overall diameter (circular cond.) 25sqmm and above - 8 x Overall Diameter (shaped cond.)
OPERATING TEMPERATURE: Maximum 90°C
STANDARDS:
BS5467: Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000V and 1900/3300V IEC60502: Power cables with extruded insulation and their accessories for rated voltages from 1kV to 30kV
Discover wholesale electrical equipment & supplies on Africa's top B2B platform. Low MOQ, fast shipping, and competitive prices for reliable sourcing.