ALUMINIUM PVC STRAIGHT CONCENTRIC BS7870 ALUMINIUM PVC STRAIGHT CONCENTRIC BS7870
ALUMINIUM PVC STRAIGHT CONCENTRIC BS7870
Availability: In Stock
  • CONDUCTOR: Aluminium                        STRANDING:  Class 1


    INSULATION:  XLPE                               OUTERSHEATH: PVC


    OUTERSHEATH COLOUR: Black            RATED VOLTAGE : 0.6/1kV


    MINIMUM BENDING RADIUS: Overall Bending Radius 8x


    OPERATING TEMPERATURE: 70°C


    STANDARDS:   BS 7870-3-11, EN 60228 Flame Retardant according to IEC/EN 60332-1-2






    Batt Part No. Core Size Colour/Reference

    16791 3 35 Black






    ELECTRICAL CHARACTERISTICS


    No. of Cores Nominal Cross Sectional Area mm2 Current Carrying Capacity AMPS (in Air) Currnet Carrying Capacity Amps (Clipped Direct) Current Carrying Capacity Amps (Enclosed in Conduit on a Wall)

    1 25 127 119 105

    1 35 158 147 128

    3 25 97 90 84

    3 35 120 112 103

     


    CONDUCTORS


    Nomincal Coross Sectional Area mm2 Maximum DC Resistance of Conductor at 20°C ohms/km Maximum DC Resistance of Concentric Conductor at 20°C ohms/km

    25 1.2 1.3

    35 0.868 0.91

     


    DIMENSIONS


    BATT Part No Cores Nominal cross sectional area of conductor Approx overall diameter Weight

    16791 3 35 25 820



  • New
ALUMINIUM WAVEFORM CABLE BS7870 ALUMINIUM WAVEFORM CABLE BS7870
ALUMINIUM WAVEFORM CABLE BS7870
Availability: In Stock

CONDUCTOR: Aluminium


STRANDING:  Class 1                 INSULATION:  XLPE


OUTERSHEATH: PVC                   OUTERSHEATH COLOUR: Black


RATED VOLTAGE: 0.6/1kV           CORE IDENTIFICATION: Brown,Black,Grey


MINIMUM BENDING RADIUS: 

95mm2: 8 x overall diameter 185mm2: 9 x overall diameter 300mm2: 10 x overall diameter


STANDARDS: BS7870-3.40






Batt Part No.

Core

Size

Colour/Reference

56398

3

95

Black

56399

3

185

Black

56400

3

300

Black





BATT Part No

Cores

Nominal cross sectional area of conductor

Minimum average thickness of insulation

Minimum average thickness of outer sheath

Approx overall diameter

Weight

56398

3

95

1.1

2.1

36

1980

56399

3

185

1.6

2.5

46

3520

56400

3

300

1.8

2.8

56

4810

Concentric Neutral/Earth Conductor

Nominal cross sectional area

Approx no of wires

Nominal Diameter of wires

Approx length of lay

95

22

1.85

250

185

41

1.85

300

300

41

1.85

440

Electrical Characteristics

Nominal cross sectional area

Nominal internal diameter ducts

Current Rating Direct in Ground

Curent Rating In Ducts

Current Rating In Air 

95

70

244

227

232

185

90

353

328

364

300

110

461

429

508

*Buried direct in ground 0.45mtr deep, +15°C ambient, soil thermal resistivity of 1.2ºC m/w.



  • New
BARE COPPER CABLE HARD DRAWN BS7884 BARE COPPER CABLE HARD DRAWN BS7884
BARE COPPER CABLE HARD DRAWN BS7884
Availability: In Stock
  • CONDUCTOR: Plain Copper


    STRANDING: Class 2


    STANDARDS: BS7884:1997




    Batt Part No.

    Core

    Size

    Colour/Reference

    16986

    1

    50

    Black

    16987

    1

    70

    Black







    BATT Part No

    Nominal cross sectional area of conductor

    Approx overall diameter

    Weight

    16960

    16

    5.1

    142

    16986

    50

    9

    444

    16258

    70

    10.7

    623

    16968

    95

    12.6

    850



  • New
BARE COPPER CABLE SOFT DRAWN BSEN 60228 BARE COPPER CABLE SOFT DRAWN BSEN 60228
BARE COPPER CABLE SOFT DRAWN BSEN 60228
Availability: In Stock
  • CONDUCTOR: Plain Copper


    STRANDING: Class 2


    CORE IDENTIFICATION: 1 core: Bare


    STANDARDS: BSEN60228



    Batt Part No.

    Core

    Size

    Colour/Reference

    16447

    1

    6

    Bare

    16793

    1

    16

    Bare

    16794

    1

    25

    Bare

    16795

    1

    35

    Bare

    16265

    1

    50

    Bare

    16245

    1

    70

    Bare

    16428

    1

    95

    Bare

    16463

    1

    120

    Bare

    16654

    1

    150

    Bare

    16370

    1

    185

    Bare







    BATT Part No

    Nominal cross sectional area of conductor

    Approx overall diameter

    Weight

    16447

    6

    3.1

    54

    16851

    10

    4

    90

    16793

    16

    5.1

    154

    16794

    25

    6.3

    214

    16795

    35

    7.5

    297

    16265

    50

    8.9

    450

    16245

    70

    10.7

    623

    16428

    95

    12.6

    850

    16463

    120

    13.1

    1080

    16654

    150

    14.5

    1268

    16370

    185

    17.6

    1660

    16827

    240

    20

    2070

    16996

    300

    22.3

    2620





  • New
COPPER LSZH SPLIT CONCENTRIC BS7870 COPPER LSZH SPLIT CONCENTRIC BS7870
COPPER LSZH SPLIT CONCENTRIC BS7870
Availability: In Stock
  • CONDUCTOR:   Plain Copper    STRANDING:  Class 2


    INSULATION: XLPE                       OUTERSHEATH: LSZH


    OUTERSHEATH COLOUR: Black, Brown   RATED VOLTAGE: 0.6/1kV


    MINIMUM BENDING RADIUS: Overall Bending Radius 15x  


    OPERATING TEMPERATURE: 70°C


    STANDARDS: Generally to BS 7870-3-21, EN 60228 Flame Retardant according to IEC/EN 60332-1-2






    ELECTRICAL CHARACTERISTICS

    Batt Part No.

    Core

    Size

    Colour/Reference

    16530

    1

    4

    Black

    16776

    1

    6

    Brown

    16757

    1

    10

    Brown

    16531

    1

    16

    Black

    16532

    1

    25

    Black

    16756

    1

    35

    Black


    Nominal Cross Sectional Area mm2

    Maximum Resistance if Conductor at 20°C

    Current Carrying Capacity Amps ( In Air )

    Current Carrying Capacity Amps ( LCipped Direct )

    Current Carrying Capacity Amps ( Enclosed in Conduit on a Wall )

    4

    4.61

    42

    41

    37

    16

    1.15

    100

    99

    88

    25

    0.727

    129

    120

    110

    35

    0.524

    135

    130

    117

     

    DIMENSIONS

    BATT Part No

    Cores

    Nominal cross sectional area of conductor

    Nominal thickness of oversheath

    Approx overall diameter

    Weight

    16530

    1

    4

     

    10

    190

    16776

    1

    6

     

    14

    530

    16757

    1

    10

     

    13

    385

    16531

    1

    16

     

    14.9

    586

    16532

    1

    25

     

    18.1

    830

    16756

    1

    35

     

    23

    1230



  • New
YMVK KEMA APPROVED PVC POWER CABLE YMVK KEMA APPROVED PVC POWER CABLE
YMVK KEMA APPROVED PVC POWER CABLE
Availability: In Stock
  • CONDUCTOR:  Plain Copper


    INSULATION:  XLPE                                   OUTERSHEATH: PVC


    OUTERSHEATH COLOUR: Grey               RATED VOLTAGE: 0.6/1kV


    CORE IDENTIFICATION: 

    2 core: Brown and Blue

    3 core: Brown, Blue and Green / Yellow

    4 core: Black, Grey, Brown and Green / Yellow

    5 core: Black, Blue, Brown, Grey and Green / Yellow

    Optional: 4 core - Black, Brown, Blue and Green / Yellow)


    MINIMUM BENDING RADIUS: 10 x overall diameter


    OPERATING TEMPERATURE: 

    Maximum 90°C, minimum bending 0°C / Short circuit temperature 250°C


    STANDARDS: HD 604 Part 4 Section D







    Batt Part No.

    Core

    Size

    Colour/Reference

    16592

    2

    1.5

    Grey

    16698

    2

    2.5

    Grey

    16699

    3

    1.5

    Grey

    16700

    3

    2.5

    Grey

    16487

    3

    4

    Grey

    16884

    3

    6

    Grey

    16917

    3

    10

    Grey

    16918

    3

    16

    Grey

    16701

    4

    1.5

    Grey

    16147

    4

    2.5

    Grey

    16703

    4

    4

    Grey

    16704

    4

    6

    Grey

    16705

    4

    10

    Grey

    16787

    4

    16

    Grey

    16907

    4

    35

    Grey

    16909

    4

    50

    Grey

    16024

    4

    120

    Grey

    16706

    5

    1.5

    Grey

    16271

    5

    2.5

    Grey

    16707

    5

    4

    Grey

    16272

    5

    6

    Grey

    16932

    5

    10

    Grey

    16941

    5

    16

    Grey

    16970

    7

    1.5

    Grey

    16971

    7

    2.5

    Grey

    16973

    12

    1.5

    Grey

    16974

    12

    2.5

    Grey

    16978

    24

    1.5

    Grey

    16979

    30

    1.5

    Grey









    BATT Part No

    No. of Cores

    Nominal cross sectional area of conductor (mm2)

    Radial thickness of insulation (mm)

    Nominal thickness of oversheath (mm)

    Approx overall diameter (mm)

    Weight

    16592

    2

    1.5

    0.70

    1.4

    9.3

    121

    16698

    2

    2.5

    0.70

    1.4

    10.1

    151

    16699

    3

    1.5

    0.70

    1.4

    9.4

    130

    16700

    3

    2.5

    0.70

    1.4

    10.3

    170

    16487

    3

    4

    0.70

    1.4

    11.2

    227

    16884

    3

    6

    0.70

    1.4

    12.6

    306

    16917

    3

    10

    0.70

    1.4

    14.6

    461

    16918

    3

    16

    0.70

    1.5

    17.6

    685

    16701

    4

    1.5

    0.70

    1.4

    10.2

    157

    16147

    4

    2.5

    0.70

    1.4

    11.1

    205

    16703

    4

    4

    0.70

    1.4

    12.2

    280

    16704

    4

    6

    0.70

    1.4

    13.7

    380

    16705

    4

    10

    0.70

    1.5

    15.8

    573

    16787

    4

    16

    0.70

    1.5

    19.1

    855

    16907

    4

    35

    0.90

    1.8

    26.1

    1756

    16909

    4

    50

    1.00

    1.9

    29.9

    2348

    16024

    4

    120

    1.20

    2.3

    44.2

    5618

    16706

    5

    1.5

    0.70

    1.4

    11.5

    199

    16271

    5

    2.5

    0.70

    1.4

    12.6

    262

    16707

    5

    4

    0.70

    1.4

    13.8

    357

    16272

    5

    6

    0.70

    1.4

    15.1

    468

    16932

    5

    10

    0.70

    1.5

    18.4

    744

    16941

    5

    16

    0.70

    1.6

    21.4

    1075

    16970

    7

    1.5

    0.70

    1.8

    12.5

     

    16971

    7

    2.5

    0.70

    1.8

    13.7

     

    16973

    12

    1.5

    0.70

    1.8

    15.8

     

    16974

    12

    2.5

    0.70

    1.8

    17.5

     

    16978

    24

    1.5

    0.70

    1.8

    24.6

     

    16979

    30

    1.5

    0.70

    1.8

    22.1

     


    • ELECTRICAL CHARACTERISTICS

    Nominal cross sectional area (mm2)

    Current carrying capacity (In Ground)

    Current carrying capacity (In Air)

    Max conductor DC resistance at 20°C (ohm/km)

    1.5

    30

    24

    12.1

    2.5

    24

    32

    7.41

    4

    52

    42

    4.61

    6

    64

    53

    3.08

    10

    86

    73

    1.83

    16

    11

    93

    1.15

    35

    173

    160

    0.524

    50

    205

    195

    0.387

    120

    390

    407

    0.124



  • New
YMVK SS KEMA APPROVED FLEXIBLE PVC POWER CABLE YMVK SS KEMA APPROVED FLEXIBLE PVC POWER CABLE
YMVK SS KEMA APPROVED FLEXIBLE PVC POWER CABLE
Availability: In Stock
  • ONDUCTOR: Plain Copper                       STRANDING: Class 5


    INSULATION: XLPE                                 BEDDING: PVC


    OUTERSHEATH: PVC                              OUTERSHEATH COLOUR: Grey


    RATED VOLTAGE: 0.6/1kV


    CORE IDENTIFICATION:

    Single core: Black

    2 core - Brown and Blue

    3 core - Brown, Blue and Green / Yellow

    4 core - Black, Grey, Brown and Green / Yellow

    5 core -Black, Blue, Brown, Grey and Green / Yellow

    Optional: 4 core - Black, Brown, Blue and Green / Yellow


    MINIMUM BENDING RADIUS: 5 x overall diameter


    OPERATING TEMPERATURE: Maximum 90°C, minimum bending 0°C


    STANDARDS: HD 604 Part 4 Section D







    Batt Part No.

    Core

    Size

    Colour/Reference

    16983

    1

    95

    Grey

    16980

    1

    240

    Grey

    16430

    4

    25

    Grey

    16814

    4

    70

    Grey

    16037

    4

    95

    Grey

    16285

    4

    120

    Grey

    16290

    4

    240

    Grey

    16878

    5

    25

    Grey

    16962

    5

    50

    Grey

    16861

    5

    70

    Grey

    16862

    5

    95

    Grey

    16035

    5

    120

    Grey








    BATT Part No

    No of cores

    Nominal cross sectional area of conductor mm2

    Approx overall diameter

    Weight

    Current ratings amps (open air 30°C)

    Current ratings amps (Buried 20°C)

    16983

    1

    95

    17.9

    970

    328

    211

    16980

    1

    240

    27.4

    2449

    607

    351

    16430

    4

    25

    24.1

    1340

    127

    101

    16814

    4

    70

    36.3

    3307

    246

    178

    16037

    4

    95

    41.4

    4440

    298

    211

    16285

    4

    120

    46.6

    5680

    346

    240

    16290

    4

    240

    64.3

    11365

    538

    351

    16878

    5

    25

    26.1

    1639

    127

    101

    16962

    5

    50

    34.5

    2915

    192

    144

    16861

    5

    70

    39.5

    4067

    246

    178

    16862

    5

    95

    46.8

    5623

    398

    211

    16035

    5

    120

    51

    7042

    346

    240



  • New
YMZ1K KEMA APPROVED LSZH POWER CABLE YMZ1K KEMA APPROVED LSZH POWER CABLE
YMZ1K KEMA APPROVED LSZH POWER CABLE
Availability: In Stock
  • CONDUCTOR:   Plain Copper                    STRANDING:   Class 1


    INSULATION: XLPE                                   OUTERSHEATH: LSZH


    OUTERSHEATH COLOUR: Grey              RATED VOLTAGE: 0.6/1kV


    CORE IDENTIFICATION: 

    3 core - Blue, Brown, Green/Yellow

    4 core - Brown, Black, Grey, Green/Yellow

    5 core - Blue, Brown, Black, Grey, Green/Yellow


    MINIMUM BENDING RADIUS: 10 x overall diameter


    OPERATING TEMPERATURE:  Maximum Operating: 90°C


    STANDARDS: HD-604-5-C KEMA K42C-1-5






    Batt Part No.

    Core

    Size

    Colour/Reference

    16662

    3

    1.5

    Grey

    16673

    3

    2.5

    Grey

    16679

    4

    1.5

    Grey

    16681

    4

    2.5

    Grey

    16684

    5

    1.5

    Grey

    16695

    5

    2.5

    Grey







    BATT Part No

    No. of cores

    Nominal cross sectional area of conductor (mm2)

    Radial thickness of insulation (mm)

    Nominal thickness of oversheath (mm)

    Approx overall diameter (mm)

    Weight

    16662

    3

    1.5

    0.70

    1.8

    11.0

    170

    16673

    3

    2.5

    0.70

    1.8

    11.8

    211

    16679

    4

    1.5

    0.70

    1.8

    11.7

    198

    16681

    4

    2.5

    0.70

    1.8

    12.6

    249

    16684

    5

    1.5

    0.70

    1.8

    12.5

    230

    16695

    5

    2.5

    0.70

    1.8

    13.5

    292


    • ELECTRICAL CHARACTERISTICS

    Nominal cross sectional area (mm2)

    Current carrying capacity (In Ground)

    Current carrying capacity (In Air)

    Maximum conductor DC resistance at 20°C (ohm/km)

    1.5

    30

    24

    12.1

    2.5

    24

    32

    7.41



  • New
YMZ1K-SS KEMA APPROVED FLEXIBLE LSZH POWER CABLE YMZ1K-SS KEMA APPROVED FLEXIBLE LSZH POWER CABLE
YMZ1K-SS KEMA APPROVED FLEXIBLE LSZH POWER CABLE
Availability: In Stock
  • CONDUCTOR: Plain Copper                   STRANDING: Class 5


    INSULATION: XLPE                                 OUTERSHEATH: LSZH


    OUTERSHEATH COLOUR: Grey             RATED VOLTAGE: 0.6/1kV


    CORE IDENTIFICATION

    1 core - Black

    4 core - Brown, Black, Grey, Green/Yellow

    5 core - Black, Brown, Blue, Grey, Green/Yellow


    MINIMUM BENDING RADIUS:        12 x overall diameter


    OPERATING TEMPERATURE:   Max. operating temp: 90ᴼC


    STANDARDS:     HD-604-5-C KEMA K42C-1-5




    Batt Part No.

    Core

    Size

    Colour/Reference

    16739

    1

    120

    Grey

    16730

    4

    95

    Grey

    16728

    4

    150

    Grey

    16713

    4

    185

    Grey

    16702

    5

    25

    Grey

    16640

    5

    35

    Grey









    BATT Part No

    No of Cores

    Nominal cross sectional area of conductor (mm2)

    Nominal thickness of insulation (mm)

    Nominal thickness of oversheath (mm)

    Approx overall diameter (mm)

    Weight (kg/km)

    16739

    1

    120

    1.20

    1.5

    19.4

    1178

    16730

    4

    95

    1.10

    2.1

    42.5

    4490

    16728

    4

    150

    1.4

    2.4

    53.3

    6988

    16713

    4

    185

    1.6

    2.6

    61.2

    8753

    16702

    5

    25

    0.90

    1.8

    28.7

    1686

    16640

    5

    35

    0.90

    1.8

    31.2

    2216



    • ELECTRICAL CHARACTERISTICS
      Single Core

    Nominal cross sectional area (mm2)

    Current carrying capacity In Conduit (Flat Formation)

    Current carrying capacity In Conduit (Trefoil Formation)

    Current carrying capacity In Air (Flat Formation)

    Current carrying capacity In Air (Trefoil Formation)

    Max conductor resistance at 20°C (Ω/km)

    120

    404

    341

    457

    370

    0.153


    • Multi Core

    Nominal cross sectional area (mm2)

    Current carrying capacity (In Ground)

    Current carrying capacity (In Air)

    Max conductor resistance at 20°C (Ω/km)

    25

    139

    126

    7.41

    35

    168

    155

    4.61

    95

    294

    296

    0.193

    150

    378

    395

    0.124

    185

    428

    455

    0.0991



  • New
33KV ALUMINIUM WINDFARM CABLE MDPE BS7870-4.10 33KV ALUMINIUM WINDFARM CABLE MDPE BS7870-4.10
33KV ALUMINIUM WINDFARM CABLE MDPE BS7870-4.10
Availability: In Stock
  • CONDUCTOR:   Aluminium               STRANDING:    Class 2


    INSULATION:    XLPE                        METALLIC SCREEN:  Copper Wire Screen


    OUTERSHEATH:        MDPE              OUTERSHEATH COLOUR:      Black


    RATED VOLTAGE:     19/33kV           MINIMUM BENDING RADIUS:       20 x Overall Diameter


    STANDARDS:        BS7870-4.10



    Batt Part No.

    Core

    Size

    Colour/Reference

    56719

    1

    70

    Black

    56751

    1

    95

    Black

    56720

    1

    120

    Black

    56721

    1

    150

    Black

    56698

    1

    185

    Black

    56722

    1

    240

    Black

    56699

    1

    300

    Black

    56723

    1

    400

    Black

    56724

    1

    500

    Black

    56725

    1

    630

    Black









    Nominal Cross Sectional Area of Conductor (mm)

    Weight (kg/km)

    Max. DC Resistance at 20o C (ohm/km)

    Max. AC resistance at 90o C (ohm/km)

    70

    1240

    0.443

    0.5682

    95

    1360

    0.32

    0.4106

    120

    1500

    0.253

    0.328

    150

    1615

    0.206

    0.2646

    185

    1770

    0.164

    0.2109

    240

    2010

    0.125

    0.1611

    300

    2350

    0.1

    0.132

    400

    2640

    0.0778

    0.1013

    500

    3000

    0.0605

    0.081

    630

    3540

    0.0469

    0.064


    •  

    BATT Part No

    Nominal cross sectional area of conductor (sqmm)

    Nominal Insulation Thickness (mm)

    Overall Diameter (mm)

    56719

    70

    8

    35.5

    56751

    95

    8

    37.2

    56720

    120

    8

    38

    56721

    150

    8

    40.2

    56698

    185

    8

    41.9

    56722

    240

    8

    44.4

    56699

    300

    8

    47.5

    56723

    400

    8

    50.1

    56724

    500

    8

    54

    56725

    630

    8

    58.3




  • New
MEDIUM VOLTAGE AWA LSZH COPPER BS7835 MEDIUM VOLTAGE AWA LSZH COPPER BS7835
MEDIUM VOLTAGE AWA LSZH COPPER BS7835
Availability: In Stock
  • CONDUCTOR:  Plain Copper             STRANDING:  Class 2


    INSULATION: XLPE                            METALLIC SCREEN: Plain Copper Taped Screen


    BEDDING: LSZH                                 ARMOUR: Aluminium Wire Armour


    OUTERSHEATH: LSZH                      OUTERSHEATH COLOUR: Red


    RATED VOLTAGE: 6.35/11kV              MINIMUM BENDING RADIUS: 15 x Overall Diameter


    OPERATING TEMPERATURE: 90°C


    STANDARDS:    BS7835, BS EN 60332-1-2.


    Batt Part No.

    Core

    Size

    Colour/Reference

    56182

    1

    70

    Red

    56222

    1

    95

    Red

    56387

    1

    120

    Red

    56600

    1

    50

    Red

    56034

    1

    85

    Red

    56368

    1

    240

    Red

    56229

    1

    300

    Red

    56168

    1

    400

    Red

    56329

    1

    500

    Red

    56035

    1

    630

    Red






    BATT Part No

    Size mm

    RT of insulation mm

    Nominal diameter over CTS mm

    RT of bedding mm

    Diameter over Bedding mm

    Diameter of armour wires mm

    Diameter over Armour mm

    Approx overall Diameter mm

    Weight

    56182

    70

    3.4

    20.2

    1.2

    22.9

    1.6

    26.4

    29

    1500

    56222

    95

    3.4

    22.3

    1.2

    25

    1.6

    28.5

    31

    1800

    56387

    120

    3.4

    23.5

    1.2

    26.2

    1.6

    30.5

    32.5

    2100

    56600

    150

    3.4

    25

    1.5

    27.7

    2

    32

    35

    2400

    56034

    185

    3.4

    26.8

    1.2

    29.5

    2

    33.8

    36.5

    2800

    56368

    240

    3.4

    29.1

    1.2

    31.8

    2

    36.1

    39

    3400

    56229

    300

    3.4

    31.6

    1.2

    34.3

    2

    38.6

    41

    4100

    56168

    400

    3.4

    34.4

    1.2

    37.1

    2

    42.4

    45

    5000

    56329

    500

    3.4

    37.6

    1.3

    40.5

    2.5

    45.8

    49.5

    6300

    630

    630

    3.4

    41.5

    1.4

    44.6

    2.5

    49.9

    54

    7800




  • New
MEDIUM VOLTAGE AWA PVC COPPER BS6622 MEDIUM VOLTAGE AWA PVC COPPER BS6622
MEDIUM VOLTAGE AWA PVC COPPER BS6622
Availability: In Stock
  • CONDUCTOR:    Plain Copper                    STRANDING:       Class 2


    INSULATION:        XLPE                             METALLIC SCREEN:     Plain Copper Taped Screen


    BEDDING:                     PVC                        ARMOUR:                     Aluminium Wire Armour


    OUTERSHEATH:           PVC                       OUTERSHEATH COLOUR:    Red


    RATED VOLTAGE:                  6.35/11kV      MINIMUM BENDING RADIUS:     15 x Overall Diameter


    OPERATING TEMPERATURE:     90°C


    STANDARDS:           BS6622, BS EN 60332-1-2.



    ominal cross sectional area of conductor

    RT of Insulation

    Nominal Diameter over copper screen

    RT of Bedding mm

    Diameter over bedding

    Diameter of armour wire

    Diameter of armour

    Approx overall diameter mm

    Weight

    95

    3.4

    22.3

    1.2

    25

    1.6

    28.5

    32.8

    1850

    120

    3.4

    23.5

    1.2

    26.2

    1.6

    30.5

    34.8

    2160

    150

    3.4

    25

    1.2

    27.7

    2

    32

    36.5

    2590

    185

    3.4

    26.8

    1.2

    29.5

    2

    33.8

    38.3

    2980

    240

    3.4

    29.1

    1.2

    31.8

    2

    36.1

    36.1

    3640

    300

    3.4

    31.6

    1.2

    34.3

    2

    38.6

    38.6

    4330

    400

    3.4

    34.4

    1.2

    37.1

    2.5

    42.4

    42.4.

    5480

    500

    3.4

    37.6

    1.3

    40.5

    2.5

    45.8

    45.8

    6550

    630

    3.4

    41.5

    1.4

    44.6

    2.5

    49.9

    49.9

    8080






  • New
MEDIUM VOLTAGE SWA LSZH COPPER BS7835 MEDIUM VOLTAGE SWA LSZH COPPER BS7835
MEDIUM VOLTAGE SWA LSZH COPPER BS7835
Availability: In Stock
  • CONDUCTOR:   Plain Copper               STRANDING:  Class 2


    INSULATION:  XLPE                             METALLIC SCREEN:    Plain Copper Taped Screen


    BEDDING:   LSZH                                  ARMOUR:  Steel Wire Armour


    OUTERSHEATH: LSZH                         OUTERSHEATH COLOUR: Red


    RATED VOLTAGE:   6.35/11kV


    CORE IDENTIFICATION:   Coloured Tapes: Brown, Black, Grey


    MINIMUM BENDING RADIUS:  12 x Overall Diameter


    OPERATING TEMPERATURE:  90°C               STANDARDS:  BS7835, BS EN 60332-1-2






    Batt Part No.

    Core

    Size

    Colour/Reference

    56182

    1

    70

    Red

    56222

    1

    95

    Red

    56387

    1

    120

    Red

    56600

    1

    150

    Red

    56034

    1

    85

    Red

    56368

    1

    240

    Red

    56229

    1

    300

    Red

    56168

    1

    400

    Red

    56329

    1

    500

    Red

    56035

    1

    630

    Red









    • DE-RATING FACTORS

    Air Temperature °C

    25

    30

    35

    40

    45

    50

    55

    De-Rating Factor

    1

    0.96

    0.92

    0.88

    0.83

    0.78

    0.73


    Ground Temperature °C

    10

    15

    20

    25

    30

    35

    40

    De-Rating Factor

    103

    1

    0.97

    0.93

    0.89

    0.86

    0.82


    Ground Thermal Restistvity km/W

    0.9

    1

    1.2

    1.5

    2

    2.5

    3

    De-Rating Factor

    1.06

    1.04

    1

    0.92

    0.82

    0.74

    0.68


    Depth of Laying m

    0.80

    1

    1.25

    1.50

    1.75

    2

    2.50

    De-Rating Factor

    1

    0.97

    0.95

    0.94

    0.93

    0.91

    0.90



    • DIMENSIONS

    BATT Part No

    Cores

    Nominal cross sectional area of conductor

    Nominal Diameter mm Under armour

    Nominal Diameter mm Over Armour

    Nominal Diameter mm Overall

    Weight

    56182

    1

    70

    23

    26.2

    30.5

    1540

    56222

    1

    95

    24.7

    27.9

    32.8

    1850

    56387

    1

    120

    26.7

    29.9

    33.1

    2200

    56600

    1

    150

    27.5

    31.5

    36

    2600

    56034

    1

    185

    29.3

    33.3

    37.2

    3000

    56368

    1

    240

    31.6

    35.6

    40.8

    3640

    56229

    1

    300

    34.6

    38.6

    42.3

    4300

    56168

    1

    400

    37

    41

    45.2

    5200

    56329

    1

    500

    40.5

    45.5

    49.5

    6500

    56035

    1

    630

    44.6

    49.6

    55.6

    8080

    56140

    3

    25

    -

    -

    48.9

    4300

    56567

    3

    35

    41.6

    46.6

    51.1

    4600

    56568

    3

    50

    44.4

    49.4

    51

    4600

    56570

    3

    70

    48.1

    53.1

    56

    6300

    56569

    3

    95

    52

    57

    63.5

    8200

    56529

    3

    120

    55.6

    60.6

    65.4

    8700

    56538

    3

    150

    58.6

    63.6

    68.6

    9700

    56549

    3

    240

    68.1

    74.4

    78.9

    14300

    56598

    3

    300

    735

    79.8

    84.7

    16600

    56150

    3

    400

    79.3

    84.6

    92.2

    20000



  • New
MEDIUM VOLTAGE SWA PVC ALUMINIUM BS6622 MEDIUM VOLTAGE SWA PVC ALUMINIUM BS6622
MEDIUM VOLTAGE SWA PVC ALUMINIUM BS6622
Availability: In Stock
  • CONDUCTOR:       Aluminium


    STRANDING:        Class 2              INSULATION:         XLPE


    METALLIC SCREEN:                 Plain Copper Taped Screen             BEDDING:   PVC


    ARMOUR:  Steel Wire Armour                 OUTERSHEATH:  PVC


    OUTERSHEATH COLOUR:  Red             RATED VOLTAGE:   6.35/11kV


    CORE IDENTIFICATION:    Coloured tape, Black, Brown & Grey


    MINIMUM BENDING RADIUS: 

    Single core cables: 20 x overall diameter, Multi-core cables: 15 x overall diameter


    OPERATING TEMPERATURE: 90°C


    STANDARDS:

    BS6622: Power cables, thermosetting polymer insulated high voltage IEC60502-2: Power cables with extruded insulation and their accessories for rated voltages from 6kV to 30kV (Um=36kV) Flame Propagation to BS EN 60332-1-2







    Batt Part No.

    Core

    Size

    Colour/Reference

    56507

    3

    95

    Red

    56059

    3

    185

    Red

    56664

    3

    300

    Red









    BATT Part No

    Number of cores

    Nominal cross sectional area of conductor

    Radial thickness of insulation

    Nominal thickness off extruded bedding

    Nominal steel armour wire diameter

    Nominal thickness of oversheath

    Approx overall diameter

    Weight

    56507

    3

    95

     

     

     

     

     

    9800

    56059

    3

    185

     

     

     

     

     

    12250

    56664

    3

    300

     

     

     

     

     

    15500


    BATT Part No

    Continuous current rating in ground

    Continuous current rating in ducts

    Continuous current rating in air

    Trefoil A

    Flat A

    Trefoil A

    Flat A

    Trefoil A

    Flat A

    Trefoil A

    56507

    230

    230

    200

    200

    250

    250

    56059

    335

    335

    290

    290

    385

    385

    56664

    435

    435

    375

    375

    510

    510



  • New
MEDIUM VOLTAGE SWA PVC COPPER BS6622 MEDIUM VOLTAGE SWA PVC COPPER BS6622
MEDIUM VOLTAGE SWA PVC COPPER BS6622
Availability: In Stock
  • CONDUCTOR:    Plain Copper


    STRANDING:      Class 2                INSULATION:    XLPE


    METALLIC SCREEN:    Plain Copper Taped Screen       BEDDING:  PVC


    ARMOUR:      Steel Wire Armour              OUTERSHEATH:     PVC


    OUTERSHEATH COLOUR:   Red             RATED VOLTAGE:          6.35/11kV


    CORE IDENTIFICATION:     Coloured Tapes: Brown, Black, Grey


    MINIMUM BENDING RADIUS:   15 x Overall Diameter  


    OPERATING TEMPERATURE:    90°C


    STANDARDS:   BS 6622, IEC/EN 60228







    Batt Part No.

    Core

    Size

    Colour/Reference

    56535

    3

    70

    Red

    56519

    3

    95

    Red

    56532

    3

    120

    Red

    56520

    3

    150

    Red

    56559

    3

    185

    Red

    56551

    3

    240

    Red








    • DE-RATING FACTORS 

    Air Temperature °C

    25

    30

    35

    40

    45

    50

    55

    De-Rating Factor

    1.00

    0.96

    0.92

    0.88

    0.83

    0.78

    0.73

    Ground Temperature °C

    10

    15

    20

    25

    30

    35

    40

    De-Rating Factor

    1.03

    1.00

    0.97

    0.93

    0.89

    0.86

    0.82

    Ground Thermal Resistivity km/W

    0.9

    1.0

    1.2

    1.5

    2.0

    2.5

    3.0

    De-rating Factor

    1.06

    1.04

    1.00

    0.92

    0.82

    0.74

    0.62

    Depth of Laying m

    0.80

    1.00

    1.25

    1.50

    1.75

    2.00

    2.50

    De-Rating Factor

    1.00

    0.97

    0.95

    0.94

    0.93

    0.91

    0.90


    • ELECTRICAL CHARACTERISTICS

    No of Cores

    Nominal Cross Sectional Area mm2

    Continuous Ratings Amps In Ground Trefoil

    Continuous Ratings Amps In Ground Flat

    Continuous Ratings Amps Ducts Trefoil

    Continuous Ratings Amps in Ducts Flat

    Continuous Ratings Amps In air Trefoil

    Continuous Ratings Amps in air Flat

    3

    70

    250

    250

    215

    215

    270

    270

    3

    95

    300

    300

    255

    255

    330

    330

    3

    120

    340

    340

    290

    290

    380

    380

    3

    150

    380

    380

    330

    330

    430

    430

    3

    185

    430

    430

    370

    370

    490

    490

    3

    240

    500

    500

    430

    430

    570

    570



    • DIMENSIONS

    BATT Part No

    Cores

    Nominal cross sectional area of conductor

    Approx overall diameter

    Weight

    56535

    3

    70

    57.5

    6300

    56519

    3

    95

    61.6

    7500

    56532

    3

    120

    65.4

    9400

    56520

    3

    150

    68.6

    9700

    56559

    3

    185

    72.7

    11400

    56551

    3

    240

    78.9

    14300

    56597

    3

    300

    84.7

    16600



  • New