Batt Marineflex  and Marineflex-B is the designed for fixed installation on open decks of ships and various offshore environments. Engineered with flexibility, it guarantees hassle-free installation, while its low smoke and zero halogen compounds offer unparalleled peace of mind during emergencies. 

For enhanced safety, our '331' fire-resistant versions ensure the preservation of life by maintaining critical ship systems even when directly on fire.


Technical Details:

UPC: 120000090
Seller SKU: bnc0000091
Condition: New
Availability: In Stock
Minimum order quantity: 100
Date first listed on Zandaux: Jun 20, 2024
  • CONDUCTOR: Plain Copper          STRANDING: Flexible


    INSULATION: MGT+XLPE      OUTERSHEATH: SHF1


    OUTERSHEATH COLOUR: Black      RATED VOLTAGE: 0.6/1kV


    CORE IDENTIFICATION: 

    1 Core - Black

    2 Core - Black and Light Blue

    3 Core - Black, Brown and Light Blue

    4 Core - Black, Blue, Brown and White

    5 Core and Above - White and numbered


    OPERATING TEMPERATURE: 90°C


    STANDARDS: IEC60092-353, IEC60332-1, IEC60332-3-22, IEC60754-1, IEC60754-2, IEC61034-2, CSA C22.2.                








    Batt Part No.

    Core

    Size

    Colour/Reference

    Cores

    14374

    1

    35

    Black

    Black, light blue

    14375

    1

    50

    Black

     

    14331

    1

    240

    Black

     

    14162

    2

    1.5

    Black

     

    14130

    2

    2.5

    Black

     

    14376

    2

    6

    Black

     

    14377

    2

    10

    Black

     

    14116

    3

    1.5

    Black

     

    14115

    3

    2.5

    Black

     

    14371

    3

    6

    Black

     

    14379

    3

    10

    Black

     

    14186

    3

    16

    Black

     

    14346

    3

    50

    Black

     

    14189

    4

    1.5

    Black

     

    14114

    4

    2.5

    Black

     

    14378

    4

    10

    Black

     

    14380

    5

    1.5

    Black

     

    14118

    7

    1.5

    Black

     

    14288

    12

    1.5

    Black

     

    14381

    14

    1.5

    Black

     

    14117

    19

    1.5

    Black











    Construction mm2

    Conductor diameter approx. (mm)

    Insulation thickness nominal (mm)

    Outer sheath thickness approx. (mm)

    Overall diameter approx. (mm)

    Weight approx. (kg/km)

    Min bending radius approx. (mm)

    Current rating at 45°C in air approx. (a)

    Conductor resistance at 20°C (Z/KM)

    Short circuit rating (kA)

    BATT Part No

    1x1.5

    1.6

    0.7

    0.9

    5.2

    34

    21

    28

    12.200

    0.21

     

    1x2.5

    2

    0.7

    1

    5.9

    48

    24

    35

    7.560

    0.35

     

    1x4

    2.4

    0.7

    1

    6.6

    65

    26

    47

    4.700

    0.58

     

    1x6

    3.2

    0.7

    1

    7.1

    87

    29

    58

    3.110

    0.87

     

    1x10

    3.9

    0.7

    1

    7.9

    143

    32

    70

    1.840

    1.46

     

    1x16

    5.1

    0.7

    1.1

    9.3

    212

    37

    93

    1.160

    2.33

     

    1x25

    6.7

    0.9

    1.52

    11.5

    321

    46

    117

    0.735

    3.65

     

    1x35

    7.4

    0.9

    1.5

    12.8

    443

    51

    147

    0.530

    5.11

    14374

    1x50

    8.8

    1.0

    1.3

    14.4

    604

    57

    180

    0.391

    7.30

    14375

    1x70

    10

    1.1

    1.4

    16.9

    824

    67

    283

    0.270

    10.20

     

    1x95

    12.8

    1.1

    1.4

    18.8

    1067

    75

    285

    0.195

    13.9

     

    1x120

    14

    1.2

    1.5

    20.9

    1328

    89

    333

    0.154

    17.50

     

    1x150

    15.3

    1.4

    1.6

    23.1

    1652

    92

    386

    0.126

    21.90

     

    1x185

    16.7

    1.6

    1.6

    24.0

    1995

    96

    444

    0.100

    27

     

    1x240

    19.8

    1.7

    1.8

    28.4

    2584

    114

    528

    0.076

    35

    14331

    1x300

    22.4

    1.8

    1.9

    31.0

    3185

    124

    612

    0.061

    43.80

     



    • Two core

    Construction (mm²

    Conductor diameter approx. (mm)

    Insulation thickness nominal (mm)

    Outer sheath thickness approx. (mm)

    Overall diameter approx. (mm)

    Weight approx. (kg/km)

    Min bending radius approx. (mm)

    Current rating at 45°C in air approx. (a)

    Conductor resistance at 20°C (Z/KM)

    Short circuit rating (kA

    BATT Part No

    2x1.5

    1.6

    0.7

    1.1

    9

    92

    36

    23

    12.200

    0.21

    14162

    2x2.5

    2

    0.7

    1.1

    10

    123

    40

    31

    7.560

    0.35

    14130

    2x4

    2.7

    0.7

    1.2

    11.5

    173

    46

    43

    4.700

    0.58

     

    2x6

    3.2

    0.7

    1.2

    12.6

    226

    50

    55

    3.110

    0.87

     

    2x10

    3.9

    0.7

    1.3

    15.9

    394

    63

    75

    1.840

    1.46

     

    2x16

    5.1

    0.7

    1.4

    18.7

    564

    75

    100

    1.160

    2.33

     

    2x25

    6.7

    0.9

    1.6

    23.4

    866

    94

    130

    0.735

    3.65

     

    2x35

    7.4

    0.9

    1.7

    25.3

    1083

    101

    161

    0.530

    5.11

     

    2x50

    8.8

    1.0

    1.8

    28.4

    1501

    113

    196

    0.391

    7.30

     

    2x70

    10

    1.1

    2

    33.7

    2016

    135

    236

    0.270

    10.20

     

    2x95

    12.8

    1.1

    2.2

    38.2

    2701

    153

    287

    0.195

    13.90

     



    • Three core

    Construction (mm²)

    Conductor diameter approx. (mm)

    Insulation thickness nominal (mm)

    Outer sheath thickness approx. (mm)

    Overall diameter approx. (mm)

    Weight approx. (kg/km)

    Min bending radius approx. (mm)

    Current rating at 45°C in air approx. (a)

    Conductor resistance at 20°C (Z/KM)

    Short circuit rating (kA)

    BATT Part No

    3x1.5

    1.6

    0.7

    1.1

    9.5

    110

    38

    20

    12.200

    0.21

    14116

    3x2.5

    2

    0.7

    1.1

    10.6

    150

    43

    28

    7.560

    0.35

    14115

    3x4

    2.7

    0.7

    1.2

    12.2

    213

    49

    37

    4.700

    0.58

     

    3x6

    3.2

    0.7

    1.3

    13.6

    289

    55

    47

    3.110

    0.87

     

    3x10

    3.9

    0.7

    1.3

    15.9

    474

    63

    65

    1.840

    1.46

     

    3x16

    5.1

    0.7

    1.4

    18.7

    685

    75

    87

    1.160

    2.33

    14186

    3x25

    6.7

    0.9

    1.6

    23.4

    1046

    94

    110

    0.735

    3.65

     

    3x35

    7.4

    0.9

    1.7

    25.3

    1351

    101

    137

    0.530

    5.11

    14289

    3x50

    8.8

    1.0

    1.8

    28.4

    1853

    113

    167

    0.391

    7.30

     

    3x70

    10

    1.1

    2

    33.7

    2574

    135

    214

    0.270

    10.20

     

    3x95

    12.8

    1.1

    2.2

    38.2

    3389

    153

    259

    0.195

    13.90

    14188

    3x120

    14

    1.2

    2.3

    42.5

    4244

    170

    301

    0.154

    17.50

     

    3x150

    15.3

    1.4

    2.5

    47.3

    5257

    189

    347

    0.126

    21.90

     

    3x185

    16.7

    1.6

    2.6

    49.4

    6296

    1998

    397

    0.100

    27

     

    3x240

    19.8

    1.7

    2.9

    58.8

    8307

    235

    468

    0.076

    35

     

    3x300

    22.4

    1.8

    3.1

    64.2

    10144

    257

    551

    0.0661

    43.80

     



    • Four core

    Construction (mm²)

    Conductor diameter approx. (mm)

    Insulation thickness nominal (mm)

    Outer sheath thickness approx. (mm)

    Overall diameter approx. (mm)

    Weight approx. (kg/km)

    Min bending radius approx. (mm)

    Current rating at 45°C in air approx. (a)

    Conductor resistance at 20°C (Z/KM)

    Short circuit rating (kA)

    BATT Part No

    4x1.5

    1.6

    0.7

    1.1

    10.4

    134

    42

    20

    12.200

    0.21

    14189

    4x2.5

    2

    0.7

    1.2

    11.8

    189

    47

    28

    7.560

    0.36

    14114

    4x4

    2.7

    0.7

    1.2

    13.4

    264

    54

    37

    4.700

    0.58

     

    4x6

    3.2

    0.7

    1.3

    14.9

    361

    60

    47

    3.110

    0.87

     

    4x10

    3.9

    0.7

    1.4

    17.5

    569

    70

    65

    1.840

    1.46

     

    4x16

    5.1

    0.7

    1.5

    20.7

    833

    83

    87

    1.160

    2.33

     

    4x25

    6.7

    0.9

    1.7

    25.9

    1284

    104

    110

    0.735

    3.65

     

    4x35

    7.4

    0.9

    1.8

    27.9

    1760

    112

    137

    0.530

    5.11

     

    4x50

    8.8

    1.0

    1.9

    31.4

    2401

    125

    167

    0.391

    7.30

     

    4x70

    10

    1.1

    2.1

    37.3

    3273

    149

    214

    0.270

    10.20

     

    4x95

    12.8

    1.1

    2.3

    42.3

    4347

    169

    259

    0.195

    13.90

     

    4x120

    14

    1.2

    2.5

    47.3

    5500

    189

    301

    0.154

    17.50

     

    4x150

    15.3

    1.4

    2.7

    52.5

    6819

    210

    347

    0.126

    21.90

     

    4x185

    16.7

    1.6

    2.8

    54.9

    8193

    219

    397

    0.100

    27

     

    4x240

    19.8

    1.7

    3.2

    65.4

    10750

    262

    468

    0.076

    33.80

     



    • Five core and above

    Construction (mm²)

    Conductor diameter approx. (mm)

    Insulation thickness nominal (mm)

    Outer sheath thickness approx. (mm)

    Overall diameter approx. (mm)

    Weight approx. (kg/km)

    Min bending radius approx. (mm)

    Current rating at 45°C in air approx. (a)

    Conductor resistance at 20°C (Z/KM)

    Short circuit rating (kA

    BATT Part No

    5x1.5

    1.6

    0.7

    1.2

    11.6

    177

    46

    12

    12.200

    0.21

     

    7x1.5

    1.6

    0.7

    1.2

    12.6

    216

    50

    11

    12.200

    0.21

    14118

    10x1.5

    1.6

    0.7

    1.4

    16.4

    317

    66

    10

    12.200

    0.21

     

    12x1.5

    1.6

    0.7

    1.4

    16.9

    360

    68

    9

    12.200

    0.21

    14288

    14x1.5

    1.6

    0.7

    1.4

    17.8

    405

    71

    9

    12.200

    0.21

     

    16x1.5

    1.6

    0.7

    1.4

    18.8

    457

    75

    8

    12.200

    0.21

     

    19x1.5

    1.6

    0.7

    1.5

    20.0

    528

    80

    8

    12.200

    0.21

    14117

    24x1.5

    1.6

    0.7

    1.6

    23.6

    668

    94

    7

    12.200

    0.21

     

    27x1.5

    1.6

    0.7

    1.6

    24.1

    730

    97

    7

    12.200

    0.21

     

    30x1.5

    1.6

    0.7

    1.7

    25.2

    811

    101

    6

    12.200

    0.21

     

    37x1.5

    1.6

    0.7

    1.8

    27.4

    980

    110

    6

    12.200

    0.21

     

    5x2.5

    2.0

    0.7

    1.2

    13

    239

    52

    17

    7.560

    0.36

     

    7x2.2

    2.0

    07

    1.3

    14.3

    305

    57

    15

    7.560

    0.36

     

    12x2.5

    2.0

    0.7

    1.5

    19.3

    509

    77

    13

    7.560

    0.36

     

    19x2.5

    2.0

    0.7

    1.6

    22.8

    755

    91

    11

    7.560

    0.36

     

    27x2.5

    2.0

    0.7

    1.8

    27.7

    1063

    111

    9

    7.560

    0.36

     

    37x2.5

    2.0

    0.7

    1.9

    31.2

    1407

    125

    9

    7.560

    0.36

     



No reviews