MEDIUM VOLTAGE AWA PVC COPPER BS6622 MEDIUM VOLTAGE AWA PVC COPPER BS6622
MEDIUM VOLTAGE AWA PVC COPPER BS6622
Availability: In Stock
  • CONDUCTOR:    Plain Copper                    STRANDING:       Class 2


    INSULATION:        XLPE                             METALLIC SCREEN:     Plain Copper Taped Screen


    BEDDING:                     PVC                        ARMOUR:                     Aluminium Wire Armour


    OUTERSHEATH:           PVC                       OUTERSHEATH COLOUR:    Red


    RATED VOLTAGE:                  6.35/11kV      MINIMUM BENDING RADIUS:     15 x Overall Diameter


    OPERATING TEMPERATURE:     90°C


    STANDARDS:           BS6622, BS EN 60332-1-2.



    ominal cross sectional area of conductor

    RT of Insulation

    Nominal Diameter over copper screen

    RT of Bedding mm

    Diameter over bedding

    Diameter of armour wire

    Diameter of armour

    Approx overall diameter mm

    Weight

    95

    3.4

    22.3

    1.2

    25

    1.6

    28.5

    32.8

    1850

    120

    3.4

    23.5

    1.2

    26.2

    1.6

    30.5

    34.8

    2160

    150

    3.4

    25

    1.2

    27.7

    2

    32

    36.5

    2590

    185

    3.4

    26.8

    1.2

    29.5

    2

    33.8

    38.3

    2980

    240

    3.4

    29.1

    1.2

    31.8

    2

    36.1

    36.1

    3640

    300

    3.4

    31.6

    1.2

    34.3

    2

    38.6

    38.6

    4330

    400

    3.4

    34.4

    1.2

    37.1

    2.5

    42.4

    42.4.

    5480

    500

    3.4

    37.6

    1.3

    40.5

    2.5

    45.8

    45.8

    6550

    630

    3.4

    41.5

    1.4

    44.6

    2.5

    49.9

    49.9

    8080






  • New
MEDIUM VOLTAGE SWA LSZH COPPER BS7835 MEDIUM VOLTAGE SWA LSZH COPPER BS7835
MEDIUM VOLTAGE SWA LSZH COPPER BS7835
Availability: In Stock
  • CONDUCTOR:   Plain Copper               STRANDING:  Class 2


    INSULATION:  XLPE                             METALLIC SCREEN:    Plain Copper Taped Screen


    BEDDING:   LSZH                                  ARMOUR:  Steel Wire Armour


    OUTERSHEATH: LSZH                         OUTERSHEATH COLOUR: Red


    RATED VOLTAGE:   6.35/11kV


    CORE IDENTIFICATION:   Coloured Tapes: Brown, Black, Grey


    MINIMUM BENDING RADIUS:  12 x Overall Diameter


    OPERATING TEMPERATURE:  90°C               STANDARDS:  BS7835, BS EN 60332-1-2






    Batt Part No.

    Core

    Size

    Colour/Reference

    56182

    1

    70

    Red

    56222

    1

    95

    Red

    56387

    1

    120

    Red

    56600

    1

    150

    Red

    56034

    1

    85

    Red

    56368

    1

    240

    Red

    56229

    1

    300

    Red

    56168

    1

    400

    Red

    56329

    1

    500

    Red

    56035

    1

    630

    Red









    • DE-RATING FACTORS

    Air Temperature °C

    25

    30

    35

    40

    45

    50

    55

    De-Rating Factor

    1

    0.96

    0.92

    0.88

    0.83

    0.78

    0.73


    Ground Temperature °C

    10

    15

    20

    25

    30

    35

    40

    De-Rating Factor

    103

    1

    0.97

    0.93

    0.89

    0.86

    0.82


    Ground Thermal Restistvity km/W

    0.9

    1

    1.2

    1.5

    2

    2.5

    3

    De-Rating Factor

    1.06

    1.04

    1

    0.92

    0.82

    0.74

    0.68


    Depth of Laying m

    0.80

    1

    1.25

    1.50

    1.75

    2

    2.50

    De-Rating Factor

    1

    0.97

    0.95

    0.94

    0.93

    0.91

    0.90



    • DIMENSIONS

    BATT Part No

    Cores

    Nominal cross sectional area of conductor

    Nominal Diameter mm Under armour

    Nominal Diameter mm Over Armour

    Nominal Diameter mm Overall

    Weight

    56182

    1

    70

    23

    26.2

    30.5

    1540

    56222

    1

    95

    24.7

    27.9

    32.8

    1850

    56387

    1

    120

    26.7

    29.9

    33.1

    2200

    56600

    1

    150

    27.5

    31.5

    36

    2600

    56034

    1

    185

    29.3

    33.3

    37.2

    3000

    56368

    1

    240

    31.6

    35.6

    40.8

    3640

    56229

    1

    300

    34.6

    38.6

    42.3

    4300

    56168

    1

    400

    37

    41

    45.2

    5200

    56329

    1

    500

    40.5

    45.5

    49.5

    6500

    56035

    1

    630

    44.6

    49.6

    55.6

    8080

    56140

    3

    25

    -

    -

    48.9

    4300

    56567

    3

    35

    41.6

    46.6

    51.1

    4600

    56568

    3

    50

    44.4

    49.4

    51

    4600

    56570

    3

    70

    48.1

    53.1

    56

    6300

    56569

    3

    95

    52

    57

    63.5

    8200

    56529

    3

    120

    55.6

    60.6

    65.4

    8700

    56538

    3

    150

    58.6

    63.6

    68.6

    9700

    56549

    3

    240

    68.1

    74.4

    78.9

    14300

    56598

    3

    300

    735

    79.8

    84.7

    16600

    56150

    3

    400

    79.3

    84.6

    92.2

    20000



  • New
MEDIUM VOLTAGE SWA PVC ALUMINIUM BS6622 MEDIUM VOLTAGE SWA PVC ALUMINIUM BS6622
MEDIUM VOLTAGE SWA PVC ALUMINIUM BS6622
Availability: In Stock
  • CONDUCTOR:       Aluminium


    STRANDING:        Class 2              INSULATION:         XLPE


    METALLIC SCREEN:                 Plain Copper Taped Screen             BEDDING:   PVC


    ARMOUR:  Steel Wire Armour                 OUTERSHEATH:  PVC


    OUTERSHEATH COLOUR:  Red             RATED VOLTAGE:   6.35/11kV


    CORE IDENTIFICATION:    Coloured tape, Black, Brown & Grey


    MINIMUM BENDING RADIUS: 

    Single core cables: 20 x overall diameter, Multi-core cables: 15 x overall diameter


    OPERATING TEMPERATURE: 90°C


    STANDARDS:

    BS6622: Power cables, thermosetting polymer insulated high voltage IEC60502-2: Power cables with extruded insulation and their accessories for rated voltages from 6kV to 30kV (Um=36kV) Flame Propagation to BS EN 60332-1-2







    Batt Part No.

    Core

    Size

    Colour/Reference

    56507

    3

    95

    Red

    56059

    3

    185

    Red

    56664

    3

    300

    Red









    BATT Part No

    Number of cores

    Nominal cross sectional area of conductor

    Radial thickness of insulation

    Nominal thickness off extruded bedding

    Nominal steel armour wire diameter

    Nominal thickness of oversheath

    Approx overall diameter

    Weight

    56507

    3

    95

     

     

     

     

     

    9800

    56059

    3

    185

     

     

     

     

     

    12250

    56664

    3

    300

     

     

     

     

     

    15500


    BATT Part No

    Continuous current rating in ground

    Continuous current rating in ducts

    Continuous current rating in air

    Trefoil A

    Flat A

    Trefoil A

    Flat A

    Trefoil A

    Flat A

    Trefoil A

    56507

    230

    230

    200

    200

    250

    250

    56059

    335

    335

    290

    290

    385

    385

    56664

    435

    435

    375

    375

    510

    510



  • New
MEDIUM VOLTAGE SWA PVC COPPER BS6622 MEDIUM VOLTAGE SWA PVC COPPER BS6622
MEDIUM VOLTAGE SWA PVC COPPER BS6622
Availability: In Stock
  • CONDUCTOR:    Plain Copper


    STRANDING:      Class 2                INSULATION:    XLPE


    METALLIC SCREEN:    Plain Copper Taped Screen       BEDDING:  PVC


    ARMOUR:      Steel Wire Armour              OUTERSHEATH:     PVC


    OUTERSHEATH COLOUR:   Red             RATED VOLTAGE:          6.35/11kV


    CORE IDENTIFICATION:     Coloured Tapes: Brown, Black, Grey


    MINIMUM BENDING RADIUS:   15 x Overall Diameter  


    OPERATING TEMPERATURE:    90°C


    STANDARDS:   BS 6622, IEC/EN 60228







    Batt Part No.

    Core

    Size

    Colour/Reference

    56535

    3

    70

    Red

    56519

    3

    95

    Red

    56532

    3

    120

    Red

    56520

    3

    150

    Red

    56559

    3

    185

    Red

    56551

    3

    240

    Red








    • DE-RATING FACTORS 

    Air Temperature °C

    25

    30

    35

    40

    45

    50

    55

    De-Rating Factor

    1.00

    0.96

    0.92

    0.88

    0.83

    0.78

    0.73

    Ground Temperature °C

    10

    15

    20

    25

    30

    35

    40

    De-Rating Factor

    1.03

    1.00

    0.97

    0.93

    0.89

    0.86

    0.82

    Ground Thermal Resistivity km/W

    0.9

    1.0

    1.2

    1.5

    2.0

    2.5

    3.0

    De-rating Factor

    1.06

    1.04

    1.00

    0.92

    0.82

    0.74

    0.62

    Depth of Laying m

    0.80

    1.00

    1.25

    1.50

    1.75

    2.00

    2.50

    De-Rating Factor

    1.00

    0.97

    0.95

    0.94

    0.93

    0.91

    0.90


    • ELECTRICAL CHARACTERISTICS

    No of Cores

    Nominal Cross Sectional Area mm2

    Continuous Ratings Amps In Ground Trefoil

    Continuous Ratings Amps In Ground Flat

    Continuous Ratings Amps Ducts Trefoil

    Continuous Ratings Amps in Ducts Flat

    Continuous Ratings Amps In air Trefoil

    Continuous Ratings Amps in air Flat

    3

    70

    250

    250

    215

    215

    270

    270

    3

    95

    300

    300

    255

    255

    330

    330

    3

    120

    340

    340

    290

    290

    380

    380

    3

    150

    380

    380

    330

    330

    430

    430

    3

    185

    430

    430

    370

    370

    490

    490

    3

    240

    500

    500

    430

    430

    570

    570



    • DIMENSIONS

    BATT Part No

    Cores

    Nominal cross sectional area of conductor

    Approx overall diameter

    Weight

    56535

    3

    70

    57.5

    6300

    56519

    3

    95

    61.6

    7500

    56532

    3

    120

    65.4

    9400

    56520

    3

    150

    68.6

    9700

    56559

    3

    185

    72.7

    11400

    56551

    3

    240

    78.9

    14300

    56597

    3

    300

    84.7

    16600



  • New
11KV TRIPLEX ALUMINIUM BS7870 11KV TRIPLEX ALUMINIUM BS7870
11KV TRIPLEX ALUMINIUM BS7870
Availability: In Stock

CONDUCTOR:   Aluminium                    STRANDING:  Class 2


INSULATION:   XLPE                             METALLIC SCREEN:  Copper Wire Screen


ARMOUR:  Plain Copper Wire Braid      OUTERSHEATH:  MDPE


OUTERSHEATH COLOUR:  Red            RATED VOLTAGE: 6.35/11kV


STANDARDS: BS7870-4.10







Batt Part No.

Core

Size

Colour/Reference

56606

3

95

Red

56607

3

185

Red

56608

3

300

Red


Size sq.mm

Weight kg/km

Max DC resistanct at 20°C

Max AC resistance at 90°C

Current rating laid in ground (A)

Current rating laid in air 25°C (A)

95

2901

0.320

0.413

245

285

185

3926

0.164

0.215

353

430

300

5138

0.100

0.133

461

580

 

BATT Part No

Size

Nominal Conductor Diameter mm

Nominal Conductor Screen Thickness

Diameter over Insulation mm

Insulation thickness mm

Diameter over Screen mm

Diameter over Sheath mm

Diameter in Triplex information mm

56606

95

10.65

0.7

18.95

1

23.03

27.12

58.54

56607

185

14.9

0.7

23.25

1

27.33

31.67

68.24

56608

300

19

0.7

27.3

1

31.38

36.12

77.83


  • New
MEDIUM VOLTAGE - ALUMINIUM UK POWER NETWORKS MEDIUM VOLTAGE - ALUMINIUM UK POWER NETWORKS
MEDIUM VOLTAGE - ALUMINIUM UK POWER NETWORKS
Availability: In Stock
  • CONDUCTOR:      Aluminium            STRANDING:   Class 2


    INSULATION:   XLPE                         METALLIC SCREEN:    Aluminium Wire Screen


    OUTERSHEATH:    MDPE                 OUTERSHEATH COLOUR:   Red


    RATED VOLTAGE:   6.35/11kV         STANDARDS:   IEC 60228, IEC 60502-2, IEC 60754-1




    Batt Part No.

    Core

    Size

    Colour/Reference

    56813

    3x1

    95

    Red

    56815

    3x1

    185

    Red

    56816

    3x1

    300

    Red







    BATT Part No

    Cores

    Nominal cross sectional area of conductor

    Approx overall diameter

    Weight

    56813

    3x1

    95

    60

    2440

    56815

    3x1

    185

    72

    3970

    56816

    3x1

    300

    82

    5180




  • New
WRAS APPROVED EPDM DRINKING WATER CABLE WRAS APPROVED EPDM DRINKING WATER CABLE
WRAS APPROVED EPDM DRINKING WATER CABLE
Availability: In Stock
      • CONDUCTOR :   Tinned Copper                STRANDING:   Class 5


        INSULATION:    EPDM                                OUTERSHEATH:   EPDM


        OUTERSHEATH COLOUR:   Light Blue     RATED VOLTAGE:    450/750v


        CORE IDENTIFICATION: 

        Single core - Black

        4 core - Green/Yellow, Brown, Black, Grey


        MINIMUM BENDING RADIUS: 

        Fixed: 3 x overall diameter / Flexed: 5 x overall diameter


        OPERATING TEMPERATURE: 

        Temperature Rating: -25°C to +90°C / Maximum Water Temperature: +80°C


        STANDARDS: 

        WRAS approved Certificates available on request







        Batt Part No.

        Core

        Size

        Colour/Reference

        21032

        1

        25

        Light Blue

        21017

        1

        50

        Light Blue

        21018

        1

        70

        Light Blue

        21019

        1

        95

        Light Blue

        21031

        1

        120

        Light Blue

        21028

        4

        1.5

        Light Blue

        21014

        4

        2.5

        Light Blue 

        21025

        4

        4

        Light Blue

        21022

        4

        6

        Light Blue

        21029

        4

        10

        Light Blue

        21026

        4

        16

        Light Blue

        21016

        4

        25

        Light Blue

        21020

        4

        35

        Light Blue

        21021

        4

        50

        Light Blue 

        21015

        4

        70

        Light Blue

        21023

        4

        95

        Light Blue

        21013

        4

        120

        Light Blue

        21024

        7

        2.5

        Light Blue


        BATT Part No

        No of cores

        Nominal cross sectional area of conductor (mm2)

        Approx overall diameter (mm)

        Weight (kg/km)

        21032

        1

        25

        11.7

        305

        21017

        1

        50

        15.3

        570

        21018

        1

        70

        17.6

        795

        21019

        1

        95

        19.7

        1030

        21031

        1

        120

        22.2

        1305

        21028

        4

        1.5

        10.2

        135

        21014

        4

        2.5

        11.8

        200

        21025

        4

        4

        13.2

        270

        21022

        4

        6

        14.6

        380

        21029

        4

        10

        18.8

        630

        21026

        4

        16

        21.1

        870

        21016

        4

        25

        26.3

        1310

        21020

        4

        35

        29.4

        1725

        21021

        4

        50

        34.7

        2490

        21015

        4

        70

        39.8

        3420

        21023

        4

        95

        45.4

        4480

        21013

        4

        120

        50.6

        5605

        21024

        7

        2.5

         

         

        ELECTRICAL CHARACTERISTICS

        Nominal cross sectional area (mm2)

        Current carrying capacity (Laying in Air)

        Current carrying capacity (Laying in Water)

        1.5

        23

        29

        2.5

        32

        38

        4

        42

        52

        6

        54

        67

        10

        75

        94

        16

        100

        125

        25

        127

        166

        35

        158

        205

        50

        192

        256

        70

        246

        316

        95

        298

        377

        120

        346

        438

        150

        399

        505

        185

        456

        577

        240

        538

        681

        300

        621

        785

        Conductor temperature: +90°C

        Ambient air/water temperature: +30°C



  • New
0361-TQ SINGLE CORE WELDING CABLE 0361-TQ SINGLE CORE WELDING CABLE
0361-TQ SINGLE CORE WELDING CABLE
Availability: In Stock
  • CONDUCTOR:   Tinned Copper              STRANDING:   Class 6


    INSULATION:   EPR                               OUTERSHEATH:   CSP


    OUTERSHEATH COLOUR:   Black, Orange


    MINIMUM BENDING RADIUS:   Overall Bending Radius 6x


    OPERATING TEMPERATURE:  85°C


    STANDARDS:

    BS638 part 4 * (withdrawn). EN 60228 Flame Retardant according to IEC/EN 60332-1-2   







    • DE-RATING FACTORS

    Ambient Temperature

    25°C

    30°C

    35°C

    40°C

    45°C

    De-Rating Factor

    1

    0.96

    0.91

    0.87

    0.82


    • The above table is in accordance with Table A.7 of BS 638 Part 4

      ELECTRICAL CHARACTERISTICS Duty Cycle and Current Carrying Capacity The current carrying capacity of a welding cable depends on the length of the duty cycle. The duty cycle is the length of time during which a loaded current passes through the cable over an operation
      CURRENT CARRYING CAPACITY

    Nomincal Cross Sectional Area mm2

    Current Rating for Single Cycle Operation Over A Maximim Period Of 5 Minutes Amps 100%

    Current Rating for Single Cycle Operation Over A Maximim Period Of 5 Minutes Amps85%

    Current Rating for Single Cycle Operation Over A Maximim Period Of 5 Minutes Amps 60%

    Current Rating for Single Cycle Operation Over A Maximim Period Of 5 Minutes Amps 35%

    16

    135

    145

    175

    230

    25

    180

    195

    230

    300

    35

    225

    245

    290

    375

    50

    285

    305

    365

    480

    70

    355

    385

    460

    600

    95

    430

    470

    560

    730

    120

    500

    540

    650

    850

    150

    580

    630

    750

    980

    185

    665

    720

    860

    1120

    240

    780

    850

    975

    1250



    • Class 5 Flexible Copper Conductors for Single Core and Multi-Core Cables

    Nominal Cross Sectional Area mm2

    Maximum Diameter of Wires in Conductors mm

    Maximum Resistance of Conductor at 20ºC ohms/km

    Plain Wires

    120

    0.51

    0.161

    150

    0.51

    0.129

    185

    0.51

    0.106

    240

    0.51

    0.0817



    • CONDUCTORS
      Class 6 Flexible Copper Conductors for Single Core and Multi-Core Cables
       

    Nominal Cross Sectional Area mm2

    Maximum Diameter Of Wires In Conductor mm

    Maximum Resistance Of Conductor at  20ºC ohms/km

    Plain Wires

    16

    0.21

    1.21

    25

    0.21

    0.78

    35

    0.21

    0.554

    50

    0.21

    0.386

    70

    0.21

    0.272

    95

    0.21

    0.206



    • DIMENSIONS
      Type 0361TQ - Tinned Copper Conductors

    BATT Part No

    Conductor Class

    Nominal cross sectional area of conductor

    Total Radial thickness of covering

    Approx overall diameter

    Weight

    19003

    6

    16

    2

    10.9

    212

    19006

    6

    25

    2

    12.5

    300

    19012

    6

    35

    2

    14

    403

    19034

    6

    50

    2.2

    16

    560

    19036

    6

    70

    2.4

    18.6

    776

    19042

    6

    95

    2.6

    21.2

    1035

    19029

    5

    120

    2.8

    23.1

    1300

    19031

    5

    150

    3

    24

    1900

    19032

    5

    185

    3.2

    27.9

    1944

    19060

    5

    240

    3.4

    31.5

    1064


    Batt Part No.

    Core

    Size

    Colour/Reference

    19003

    1

    16

    Orange

    19024

    1

    16

    Black

    19006

    1

    25

    Orange

    19023

    1

    25

    Black

    19012

    1

    35

    Orange

    19009

    1

    35

    Black

    19034

    1

    50

    Orange

    19005

    1

    50

    Black

    19036

    1

    70

    Orange

    19004

    1

    70

    Black

    19042

    1

    95

    Orange

    19050

    1

    95

    Black

    19029

    1

    120

    Orange

    19025

    1

    120

    Black

    19031

    1

    150

    Orange

    19048

    1

    150

    Black

    19032

    1

    185

    Orange

    19049

    1

    185

    Black


    •  period of 5 minutes, expressed as a percentage of that period. For example, if the current is flowing for the whole 5 minutes the duty cycle is 100%, and if the current is flowing for 1 minute the duty cycle is 20%. As conductor temperature varies according to the time in use as well as current, ratings shown are given as a guide. The permissible loading of the cable for duty cycles other than those shown in the table can be calculated using the following formula: I = I100 x √100/F Where: I: is the maximum permissible loading current for the required duty cycle. I 100 : is the maximum permissible loading current for a duty cycle of 100%. F : is the required duty cycle calculated as a percentage of the 5 minute operation period. Typical guidance values for different welding processes are as follows: Fully automatic welding 100% Semi-automatic welding 65 - 85% Manual welding 30 - 60% Very infrequent or occasional welding 20%


  • New
HI FLEX PVC WELDING CABLE HI FLEX PVC WELDING CABLE
HI FLEX PVC WELDING CABLE
Availability: In Stock

CONDUCTOR:     Plain Copper                                 INSULATION:     PVC


OUTERSHEATH COLOUR:   Black, Red                    RATED VOLTAGE:   750V


MINIMUM BENDING RADIUS:    Overall Bending Radius 6x


OPERATING TEMPERATURE:    70°C


STANDARDS: 

IEC60331: Tests for electric cables under fire conditions - circuit integrity IEC60332-1: Tests on electric and optical fibre cables under fire conditions Part 1: test for vertical flame propagation for a single insulated wire or cable BSEN50265: Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cables







Batt Part No.

Core

Size

Colour/Reference

19008

1

16

Black

19010

1

16

Red

19016

1

25

Black

19022

1

25

Red

19038

1

35

Black

19039

1

35

Red

19040

1

50

Black

19041

1

50

Red

19044

1

70

Black

19053

1

70

Red

19058

1

95

Black

19057

1

95

Red


BATT Part No

Nominal cross sectional area of conductor

Nomincal conductor construction

Nominal diameter of conductor mm

Outer diameter of insutlation

Insutlation thickness mm AV

Insutlation thickness mm Min

Min insutlation Resistance Ohms

Approx Weight kg/km

19008

16

204 x 0.3

5.2

8.7

1.4

1.16

1.28

200

19016

25

324 x 0.3

6.5

10.5

1.5

1.25

0.85

300

19038

35

444 x 0.3

7.8

12

1.7

1.53

0.58

410

19040

50

636 x 0.3

8.8

13.8

1.7

1.43

0.41

565

19044

70

900 x 0.3

10.8

15.9

1.9

1.61

0.28

780

19058

95

1308 x 0.3

 

 

2

1.7

 

 

15185

120

1680 x 0.3

 

 

2

1.7

 

 



  • New
SIHF MULTICORE SILICONE CABLE SIHF MULTICORE SILICONE CABLE
SIHF MULTICORE SILICONE CABLE
Availability: In Stock
  • CONDUCTOR:    Tinned Copper                 STRANDING:   Class 5


    INSULATION:   Silicone                                OUTERSHEATH:    Silicone


    OUTERSHEATH COLOUR:     Black, White, Red


    CORE IDENTIFICATION: 

    2 core: brown & blue

    3 core: brown, blue & green/yellow

    4 core: brown, black, grey & green/yellow

    5 core: brown, blue, black, grey & green/yellow

    Six core and above: Black core with white numerals


    MINIMUM BENDING RADIUS: 

    Fixed: 5 x overall diameter / Flexed: 15 x overall diameter


    OPERATING TEMPERATURE: Fixed: -60°C to +180°C


    STANDARDS: HD22.1 ÷ EN 50363 ÷ EN 60228






    Batt Part No.

    Core

    Size

    Colour/Reference

    43353

    2

    0.75

    White

    43398

    2

    0.75

    Red

    43400

    2

    1

    Red

    43120

    2

    1

    White

    43295

    2

    1.5

    Red

    43408

    2

    1.5

    White

    43303

    2

    2.5

    Red

    43323

    3

    0.75

    Black

    43604

    3

    0.75

    Red

    43418

    3

    0.75

    White

    43321

    3

    1

    Red

    43341

    3

    1.5

    Red

    43129

    3

    1.5

    White

    43240

    3

    1.5

    Black

    43463

    3

    2.5

    Red

    43559

    3

    2.5

    White

    43668

    3

    4

    Red

    43412

    3

    6

    Red

    43565

    4

    0.75

    Red

    43545

    4

    1.5

    Red

    43776

    4

    1.5

    Black

    43549

    4

    2.5

    Red

    43579

    4

    4

    Red

    43601

    4

    6

    Red

    43448

    5

    1

    Red

    43551

    5

    1.5

    Red

    43806

    5

    2.5

    Red

    43140

    7

    1

    Red

    43458

    7

    1.5

    Red

    43459

    7

    2.5

    Red

    43486

    12

    1

    Red

    43487

    12

    1.5

    Red





    BATT Part No. White

    BATT Part No. Red

    BATT Part No. Black

    No of cores

    Nominal cross sectional area of conductor (mm2)

    Approx overall diameter

    Weight (kg/km)

    43353

    43398

    -

    2

    0.75

    6.4

    54

    43120

    43400

    -

    2

    1

    6.7

    60

    43408

    43295

    -

    2

    1.5

    7.6

    82

    -

    43303

    -

    2

    2.5

    9.3

    136

    43418

    43604

    43323

    3

    0.75

    6.8

    66

    -

    43321

    -

    3

    1

    7.4

    78

    43129

    43341

    43240

    3

    1.5

    8

    98

    43559

    43463

    -

    3

    2.5

    9.7

    152

    -

    43668

    -

    3

    4

    11.5

    249

    -

    43412

    -

    3

    6

    14.2

    352

    -

    43565

    -

    4

    0.75

    7.8

    84

    -

    43545

    43776

    4

    1.5

    8.8

    122

    -

    43549

    -

    4

    2.5

    10.6

    189

    -

    43578

    -

    4

    4

    13

    330

    -

    43601

    -

    4

    6

    16.2

    429

    -

    43448

    -

    5

    1

    8.8

    116

    -

    43551

    -

    5

    1.5

    9.6

    148

    -

    43806

    -

    5

    2.5

    11.6

    229

    -

    43140

    -

    7

    1

    10

    177

    -

    43458

    -

    7

    1.5

    10.9

    232

    -

    43459

    -

    7

    2.5

    13.2

    348

    -

    43486

    -

    12

    1

    12.8

    242

    -

    43487

    -

    12

    1.5

    14.8

    332




  • New
H1Z2Z2-K SOLAR CABLE H1Z2Z2-K SOLAR CABLE
H1Z2Z2-K SOLAR CABLE
Availability: In Stock

CONDUCTOR:    Tinned Copper


STRANDING:    Class 5            OUTERSHEATH COLOUR:   Black, Red   


MINIMUM BENDING RADIUS:       4 x Overall diameter


OPERATING TEMPERATURE:    -40°C to +90°C


STANDARDS: 

EN 50618:2014 – Electric cables for photovoltaic systems (BT(DE/OT)258)   






Batt Part No.

Suitable for direct burial?

Core

Size

Colour/Reference

26036

Yes

1

4

Black

26037

Yes

1

4

Red

26038

Yes

1

6

Black

26039

Yes

1

6

Red

26040

Yes

1

10

Black

26041

Yes

1

10

Red

26053

No

1

4

Black

26054

No

1

4

Red

26055

No

1

6

Black

26056

No

1

6

Red

26027

No

1

10

Black

26058

No

1

10

Red





BATT Part No (Black)

BATT Part No (Red)

Suitable for direct burial?

Nominal cross sectional area of conductor

Nominal thickness of insulation

Nominal thickness of oversheath

Approx overall diameter

Weight (kg/km)

26036

26037

Yes

4

0.7

0.8

6.6

56

26038

26039

Yes

6

0.7

0.8

7.4

74

26040

26041

Yes

10

0.7

0.8

8.8

117

26053

26054

No

4

0.7

0.8

6.6

56

26055

26056

No

6

0.7

0.8

7.4

74

26057

26058

No

10

0.7

0.8

8.8

117


Nominal cross sectional area of conductor

Maximum Resistance 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


  • New
CW1128 EXTERNAL TELEPHONE CABLE CW1128 EXTERNAL TELEPHONE CABLE
CW1128 EXTERNAL TELEPHONE CABLE
Availability: In Stock
  • CONDUCTOR:     Plain Copper        STRANDING:   Class 1


    OUTERSHEATH COLOUR:    Black


    MINIMUM BENDING RADIUS:      10 x overall diameter


    OPERATING TEMPERATURE: 

    0°C to +40°C* (*Maximum continuous temperature of standard jelly compound)


    STANDARDS:    Generally complies with BT Specification CW1128


    Batt Part No.

    Pairs

    Size

    Colour/Reference

    42042

    5pr

    0.50

    Black

    42043

    10pr

    0.50

    Black

    42044

    20pr

    0.50

    Black

    42045

    30pr

    0.50

    Black

    42046

    50pr

    0.50

    Black

    42047

    100pr

    0.50

    Black

    42050

    1QD

    0.90

    Black

    42051

    5pr

    0.90

    Black

    42052

    10pr

    0.90

    Black

    42142

    20pr

    0.90

    Black








    BATT Part No

    No of pairs

    Nominal diameter of conductors (mm)

    Approx overall diameter (mm)

    Weight (kg/km)

    42042

    5pr

    0.50

    8

    53

    42043

    10pr

    0.50

    9.5

    79

    42044

    20pr

    0.50

    12

    141

    42045

    30pr

    0.50

    -

    -

    42046

    50pr

    0.50

    16.5

    310

    42047

    100pr

    0.50

    22

    578


    BATT Part No

    No of pairs

    Nominal diameter of conductors (mm)

    Approx overall diameter (mm)

    Weight (kg/km)

    42050

    1QD

    0.90

    -

    -

    42051

    5pr

    0.90

    -

    -

    42052

    10pr

    0.90

    -

    -

    42142

    20pr

    0.90

    -

    -


    • ELECTRICAL CHARACTERISCTICS
      CW1128 1/0.5 PJ Filled Unarmoured

    Nominal diameter of conductors (mm)

    Maximum conductor resistance at 20°C(ohms/km)

    Maximum insulation resistance at 20°C (ohms/km)

    Maximum mutal capacitance (nF/km)

    0.5

    96

    1500

    64




  • New
CW1128/1198 EXTERNAL SWA TELEPHONE CABLE CW1128/1198 EXTERNAL SWA TELEPHONE CABLE
CW1128/1198 EXTERNAL SWA TELEPHONE CABLE
Availability: In Stock
  • CONDUCTOR:   Plain Copper


    STRANDING:    Class 1                 BEDDING:   PE


    ARMOUR:   Steel Wire Armour        OUTERSHEATH COLOUR:    Black


    MINIMUM BENDING RADIUS:    10 x overall diameter


    OPERATING TEMPERATURE:  

    0°C to +40°C* (*Maximum continuous temperature of standard jelly compound)


    STANDARDS: 

    Generally complies with BT Specification CW1128/1198’





    Batt Part No.

    Pairs

    Size

    Colour/Reference

    42125

    2pr(QUAD)

    0.50

    Black

    42126

    5pr

    0.50

    Black

    42127

    10pr

    0.50

    Black

    42128

    20pr

    0.50

    Black

    42232

    30pr

    0.50

    Black

    42129

    50pr

    0.50

    Black

    42205

    2pr(QUAD)

    0.90

    Black

    42144

    5pr

    0.90

    Black

    42143

    10pr

    0.90

    Black

    42136

    20pr

    0.90

    Black

    42138

    50pr

    0.90

    Black









    BATT Part No

    No of pairs

    Nominal diameter of conductors (mm)

    Nominal diameter under armour (mm)

    Nominal diameter of armour (mm)

    Approx overall diameter (mm)

    Weight (kg/km)

    42125

    2pr(QUAD)

    0.50

    7.5

    0.9

    12.7

    191

    42126

    5pr

    0.50

    8.0

    0.9

    13.2

    218

    42127

    10pr

    0.50

    9.5

    0.9

    14.7

    259

    42128

    20pr

    0.50

    12

    0.9

    17.2

    358

    42232

    30pr

    0.50

    12.5

    1.25

    18.4

    530

    42129

    50pr

    0.50

    16.5

    2

    23.3

    851


    •  

    BATT Part No

    No of pairs

    Nominal diameter of conductors (mm)

    Nominal diameter under armour (mm)

    Nominal diameter of armour (mm)

    Approx overall diameter

    Weight (kg/km)

    42205

    2pr(QUAD)

    0.90

    9

    0.9

    14.2

    308

    42144

    5pr

    0.90

    11.5

    0.9

    16.7

    379

    42143

    10pr 

    0.90

    14

    1.25

    19.9

    605

    42136

    20pr

    0.90

    18

    2

    24.8

    1065

    42138

    50pr

    0.90

    26.5

    2

    34.5

    2142


    • ELECTRICAL CHARACTERISCTICS

    Nominal diameter of conductors (mm)

    Maximum conductor resistance at 20°C (ohms/km)

    Minimum insulation resistance (ohms/km)

    Maximum mutal capacitance (nF/km)

    0.5

    96

    1500

    64

    0.9

    30

    1500

    65


    • For 20 pairs and above the maximum mutual capacitance shall increase by 3nF/km



  • New
CW1308/LSF INTERNAL TELEPHONE CABLE CW1308/LSF INTERNAL TELEPHONE CABLE
CW1308/LSF INTERNAL TELEPHONE CABLE
Availability: In Stock
  • CONDUCTOR:    Plain Copper


    STRANDING:      Class 1                    INSULATION:  PVC


    OUTERSHEATH:   LSZH                    OUTERSHEATH COLOUR:   Black, White


    MINIMUM BENDING RADIUS:    8 x overall diameter


    OPERATING TEMPERATURE:    0°C to +70°C


    STANDARDS:   Generally complies with BT Specification CW1308







    Batt Part No.

    Pairs

    Size

    Colour/Reference

    42178

    2pr

    0.50

    White

    42179

    3pr

    0.50

    White

    42180

    4pr

    0.50

    White

    42255

    4pr

    0.50

    Black

    42181

    5pr

    0.50

    White

    42182

    6pr

    0.50

    White

    42184

    10pr

    0.50

    White

    42185

    10pr + E

    0.50

    White

    42256

    10pr + E

    0.50

    Black

    42186

    12pr

    0.50

    White

    42188

    20pr

    0.50

    White

    42257

    20pr + E

    0.50

    Black

    42189

    20pr + E

    0.50

    White

    42124

    25pr

    0.50

    White

    42190

    25pr + E

    0.50

    White

    42194

    30pr + E

    0.50

    White

    42200

    50pr + E

    0.50

    White

    42196

    100pr + E

    0.50

    White

    42259

    100pr + E

    0.50

    Black

    42198

    200pr + E

    0.50

    White








    BATT Part No White

    BATT Part No Black

    No of pairs

    Nominal diameter of conductors (mm)

    Approx overall diameter (mm)

    Weight (kg/km)

    42178

    -

    2pr

    0.50

    3.5

    18

    42179

    -

    3pr

    0.50

    4.8

    27

    42180

    42255

    4pr

    0.50

    5.8

    32

    42181

    -

    5pr

    0.50

    6.3

    39

    42182

    -

    6pr

    0.50

    6.8

    46

    42184

    -

    10pr

    0.50

    8.3

    70

    42185

    42256

    10pr + E

    0.50

    8.6

    89

    42186

    -

    12pr

    0.50

    9.1

    85

    42188

    -

    20pr

    0.50

    10.7

    135

    42189

    42257

    20pr + E

    0.50

    12

    150

    42124

    -

    25pr

    0.50

    11.4

    160

    42190

    -

    25pr + E

    0.50

    -

    -

    42194

    -

    30pr + E

    0.50

    -

    -

    42200

    -

    50pr + E

    0.50

    17

    330

    42196

    42259

    100pr + E

    0.50

    27

    660

    42198

    -

    200pr + E

    0.50

    32.0

    1297


    • E- Includes additional 1.38mm diameter insulated earth wire coloured white
      ELECTRICAL CHARACTERISCTICS

    Nominal diameter of conductors (mm)

    Minimum insulation resistance at 20°C (ohms/km)

    Maximum capacitance unbalance (pF/km)

    0.50

    50

    500


    • For 20 pairs and above the maximum mutual capacitance shall increase by 3nF/km


  • New
CW1308/PVC INTERNAL TELEPHONE CABLE CW1308/PVC INTERNAL TELEPHONE CABLE
CW1308/PVC INTERNAL TELEPHONE CABLE
Availability: In Stock
  • CONDUCTOR:     Plain Copper


    STRANDING:    Class 1                INSULATION:    PVC


    OUTERSHEATH:    PVC               OUTERSHEATH COLOUR:     Black, White


    MINIMUM BENDING RADIUS:      Overall Bending Radius 8x


    OPERATING TEMPERATURE:   70°C


    STANDARDS: 

    CW 1308, IEC/EN 60228 Flame Retardant according to IEC/EN 60332-1-2





    Batt Part No.

    Core

    Size

    Colour/Reference

    42000

    1 Pair

    1/0.5mm

    White

    42001

    2 Pair

    1/0.5mm 

    White

    42002

    3 Pair

    1/0.5mm 

    White

    42004

    3 Pair

    1/0.5mm 

    Black

    42006

    4 Pair

    1/0.5mm

    White

    42007

    4 Pair

    1/0.5mm 

    Black

    42009

    5 Pair

    1/0.5mm 

    White

    42010

    6 Pair 

    1/0.5mm

    White

    42012

    6 Pair

    1/0.5mm

    Black

    42014

    8 PAir

    1/0.5mm

    White

    42015

    10 Pair

    1/0.5mm

    White

    42016

    10 Pair

    1/0.5mm

    Black

    42019

    10 Pair

    1/0.5mm

    White

    42021

    10 Pair

    1/0.5mm

    Black

    42022

    12 Pair

    1/0.5mm

    White

    42023

    15 Pair

    1/0.5mm

    White

    42024

    20 Pair

    1/0.5mm

    Black

    42025

    20 Pair

    1/0.5mm

    Black

    42026

    20 Pair

    1/0.5mm

    White

    42028

    20 Pair

    1/0.5mm

    Black

    42030

    25 Pair

    1/0.5mm

    White

    42033

    25 Pair

    1/0.5mm

    White

    42035

    30 Pair

    1/0.5mm

    White

    42037

    30 pair

    1/0.5mm

    White

    42038

    32 Pair

    1/0.5mm

    White

    42039

    40 Pair

    1/0.5mm

    White







    1

    Orange

    Orange

    Orange

    Orange

    Orange

    Orange

    Orange

    Orange

    2

    -

    -

    Green

    Natural

    Orange

    Orange

    Green

    Orange

    3

    -

    -

    -

    Green

    Natural

    Natural

    Orange

    Natural

    4

    -

    -

    -

    -

    Green

    Natural

    Natural

    Natural

    5

    -

    -

    -

    -

    -

    Green

    Natural

    Natural

    6

    -

    -

    -

    -

    -

    -

    Natural

    Green

    7

    -

    -

    -

    -

    -

    -

    Natural

    Orange

    8

    -

    -

    -

    -

    -

    -

    Green

    Natural

    9 to 15

    -

    -

    -

    -

    -

    -

    -

    Natural

    16

    -

    -

    -

    -

    -

    -

    -

    Green


    •  

    Make-up and unit indentifaction colours 16 and 20 Pair units 

    Pair Size

    Make-up and unit indentifaction colours 16 and 20 Pair units 

    8/10 Pair

    Make-up and unit indentifaction colours 16 and 20 Pair units 

    16/20 Pair

    Make-up and unit indentifaction colours 16 and 20 Pair units 

    32/40 Pair

    Make-up and unit indentifaction colours 16 and 20 Pair units 

    50 Pair

    Make-up and unit indentifaction colours 16 and 20 Pair units 

    64/80 Pair

    Make-up and unit indentifaction colours 16 and 20 Pair units 

    100 Pair

    Make-up and unit indentifaction colours 16 and 20 Pair units 

    128/160 Pair

    Make-up and unit indentifaction colours 16 and 20 Pair units 

    256/320 Pair

    Centre 

    ½

    1

    4 x ½*

    5 x ½

    1

    1

    4 x ½

    1

    1st Layer

    -

    -

    -

    -

    6 x ½

    8 x ½

    6

    5

    2nd Layer

    -

    -

    -

    -

    -

    -

    -

    10


    • PAIR IDENTIFICATION

    Cabling Element

    Colour of Insulation A - Wire

    Colour of Insulation B - Wire

    Cabling Element

    Colour of Insulation A - Wire

    Colour iof Insulation B - Wire

    1

    White/Blue

    Blue/White

    16

    Yellow/Blue

    Blue/Yellow

    2

    White/Orange

    Orange/White

    17

    Yellow/Orange

    Orange/Yellow

    3

    White/Green

    Green/White

    18

    Yellow/Green

    Green/Yellow

    4

    White/Brown

    Brown/White

    19

    Yellow/Brown

    Brown/Yellow

    5

    White/Grey

    Grey/White

    20

    Yellow/Grey

    Grey/Yellow

    6

    Red/Blue

    Blue/Red

    21

    Biolet/Blue

    Blue/Violet

    7

    Red/Orange

    Orange/Red

    22

    Violet/Orange

    Orange/Violet

    8

    Red/Green

    Green/Red

    23

    Violet/wGreen

    Green/Violet

    9

    Red/Brown

    Brown/Red

    24

    Violet/Brown

    Brown/Violet

    10

    Red/Grey

    Grey/Red

    25

    Violet/Grey

    Grey/Violet

    11

    Black/Blue

    Blue/Black

    26

    Pink/Blue

    Blue/Pink

    12

    Black/Orange

    Orange/Black

    27

    Pink/Orange

    Orange/Pink

    13

    Black/Green

    Green/Black

    28

    Pink/Green

    Green/Pink

    14

    Black/Brown

    Brown/Black

    29

    Pink/Brown

    Brown/Pink

    15

    Black/Grey

    Grey/Black

    30

    Pink/Grey

    Grey/Pink


    • ELECTRICAL CHARACTERISCTICS

    Nominal Diameter of Conductors mm

    Minimum Insulation Resistance at 20°C

    Maximum Capacitance Unbalance pF/km

    0.5

    50

    500


    • DIMENSIONS

    BATT Part No

    No of Pairs

    Nominal cross sectional area of conductor

    Configuration

    Approx overall diameter

    Weight

    42177

    1

    0.5

     

    31.

    12

    42178

    2

    0.5

     

    3.5

    18

    42179

    3

    0.5

     

    4.8

    27

    42180

    4

    0.5

     

    5.8

    32

    42181

    5

    0.5

     

    6.3

    38

    42182

    6

    0.5

     

    6.8

    46

    42183

    8

    0.5

     

    6.2

    56.8

    42185

    10

    0.5

     

    8.6

    89

    42186

    12

    0.5

     

    6.9

    78.5

    42187

    15

    0.5

     

    7.6

    94.6

    42188

    20

    0.5

     

    10.7

    135

    42124

    25

    0.5

     

    11.4

    159

    42193

    32

    0.5

     

    10.6

    188.9

    42195

    40

    0.5 + E

     

    15

    268

    42200

    50

    0.5 + E

     

    17

    326

    42201

    60

    0.5 + E

     

    17

    374

    42202

    80

    0.5 + E

     

    22.5

    518

    42196

    100

    0.5 + E

     

    27

    664

    42197

    160

    0.5 + E

     

    30.3

    1006

    42198

    200

    0.5 + E

     

    32

    1297

    42199

    320

    0.5 + E

     

    39.4

    1921



  • New
Electrical Equipment, Components & Telecoms Buy Wholesale From Zanduax

Electrical Equipment, Components & Telecoms buy wholesale from manufacturer and supplier. Get the latest factory price.

busy...