CONDUCTOR: Plain Copper STRANDING: Class 1
INSULATION: PE OUTERSHEATH: LSZH
OUTERSHEATH COLOUR: Grey, Violet, Orange SHIELD: UTP
CORE IDENTIFICATION:
Pair 1: Blue, Blue/White
Pair 2: Orange, White/Orange
Pair 3: Green/ White/Green
Pair 4: Brown, White/Brown
MINIMUM BENDING RADIUS: Overall Bending Radius 4x
OPERATING TEMPERATURE: 60°C
STANDARDS: ISO.IEC, TIA 568C.2, YD/T1019 Flame Retardant according to BS EN/IEC 60332-1-2
ELECTRICAL CHARACTERISTICS
PERFORMANCE CHARACTERISTICS
DIMENSIONS
CONDUCTOR: Plain Copper STRANDING: Class 1
INSULATION: PE OUTERSHEATH: PVC
OUTERSHEATH COLOUR: White, Blue, Grey, Red, Yellow, Green SHIELD: UTP
CORE IDENTIFICATION:
Pair 1: Blue, White/Blue
Pair 2: Orange, White Orange
Pair 3: Green, White/Green
Pair 4: Brown, White/Brown
MINIMUM BENDING RADIUS: Overall Bending Radius 4x
OPERATING TEMPERATURE: 70°C
STANDARDS:
ISO / IEC 11801,TIA 568C.2 Flame Retardant according to BS EN/IEC 60332-1-2
ELECTRICAL CHARACTERISTICS
CHARACTERISTICS
DIMENSIONS
CONDUCTOR: Plain Copper STRANDING: Class 1
INSULATION: PE OUTERSHEATH: LSZH
OUTERSHEATH COLOUR: Black, White, Violet, Red SHIELD: UTP
CORE IDENTIFICATION:
Pair 1: Blue, White/Blue
Pair 2: Orange, White/Orange
Pair 3: Green, White/Green
Pair 4: Brown. White/Brown
MINIMUM BENDING RADIUS: Overall Bending Radius 4x
OPERATING TEMPERATURE: 60°C
STANDARDS:
ISO / IEC 11801, TIA 568C.2 Flame Retardant according to BS EN/IEC 60332-1-2
ELECTRICAL CHARACTERISTICS
PERFORMANCE CHARACTERISTICS
DIMENSIONS
CONDUCTOR: Plain Copper STRANDING: Class 1 INSULATION: PE
OUTERSHEATH COLOUR: Black, Grey SHIELD: UTP
CORE IDENTIFICATION:
Pair 1: Blue, White/Blue
Pair 2: Orange, White/Orange
Pair 3: Green, White/Green
Pair 4: Brown, White/Brown
MINIMUM BENDING RADIUS: Overall Bending Radius 4x
OPERATING TEMPERATURE: 60°C
STANDARDS: ISO / IEC 11801, TIA 568C.2, YD/T1019
ELECTRICAL CHARACTERISTICS
PERFORMANCE CHARACTERISTICS
DIMENSIONS
CONDUCTOR: Plain Copper STRANDING: Class 2
INSULATION: MGT+XLPE BEDDING: LSZH
ARMOUR: Steel Wire Armour OUTERSHEATH: LSZH
OUTERSHEATH COLOUR: Black RATED VOLTAGE: 0.6/1kV
CORE IDENTIFICATION:
3 Core: Brown, Black, Grey
4 Core: Brown, Blue, Black, Grey
5 Core: Brown, Blue, Black, Grey, Green/Yellow
MINIMUM BENDING RADIUS: 6 x Overall Diameter OPERATING TEMPERATURE: 90°C
STANDARDS : BS7846 – F120, BS8491 – F120, BS EN 60332-1 BS EN 60332-3 Categories A, B & C, IEC60754, BS EN 50267-2-1:, IEC 61034, BS EN 50268
CONDUCTOR: Plain Copper STRANDING: Class 2
INSULATION: MGT+XLPE BEDDING: LSZH
ARMOUR: Steel Wire Armour OUTERSHEATH: LSZH
OUTERSHEATH COLOUR: Black
CORE IDENTIFICATION:
2 Core: Blue, Brown
3 Core: Brown, Black, Grey
4 Core: Brown, Blue. Black, Grey
5 Core: Brown, Black, Grey, Blue, Green/Yellow
7 Core: White + Black Numbered
12 Core: White + Black Numbered
19 Core: White + Black Numbered
27 Core: White + Black Numbered
37 Core: White + Black Numbered
MINIMUM BENDING RADIUS: 6 x Overall Diameter
OPERATING TEMPERATURE: 90°C
STRANDING: Class 2 INSULATION: XLPE BEDDING: LSZH
ARMOUR: AWA (single core) or SWA (multi core) OUTERSHEATH: LSZH
OUTERSHEATH COLOUR: Black RATED VOLTAGE: 0.6/1kV
CORE IDENTIFICATION:
1 Core - Brown
2 Core - Brown, Blue
3 Core - Brown, Black & Grey (Optional: Brown, Blue & Green/Yellow)
4Core - Brown, Black, Grey & Blue (Optional: Brown, Black, Grey & Green/Yellow)
5 Core - Numbered Cores (Optional: Brown, Black, Grey, Blue + Green/Yellow)
6 Core+ - Numbered Cores (Optional: Numbered + Green/Yellow)
MINIMUM BENDING RADIUS: 1.5sqmm to 16sqmm - 6 x overall diameter (circular cond.) 25sqmm and above - 8 x overall diameter (shaped cond.)
OPERATING TEMPERATURE: Maximum 90°C. Mininum operating -25°C
STANDARDS
BS6724: Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000V and 1900/3300V, having low emission of smoke and corrosive gases when affected by fire BSEN50267-1Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Apparatus BSEN50267-2-1:Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures. Determination of the amount of halogen acid gas BSEN50266-1Common test methods for cables under fire conditions. Test for vertical flame spread of vertically-mounted bunched wires or cables IEC60502: Power cables with extruded insulation and their accessories for rated voltages from 1kV to 30kV BSEN/IEC60332-1-2: Tests on electric and optical fibre cables under fire conditions Part 1: test for vertical flame propagation for a single insulated wire or cable Section 2: procedure for 1kW pre-mixed flame BSEN61034-2:2005 Measurement of smoke density of cables burned under defined conditions. Test procedure and requirements Flame Propagation Test to BS EN 60332-1-2:2004 for single cable and BS EN 60332- 3-24:2009 (Cat C) for multiple cables
CONDUCTOR: Plain Copper STRANDING: Class 2 INSULATION: XLPE
BEDDING: PVC ARMOUR: AWA (single core) or SWA (multi core)
OUTERSHEATH: PVC OUTERSHEATH COLOUR: Black RATED VOLTAGE: 0.6/1kV
CORE IDENTIFICATION:
One Core - Brown
Two Core - Brown, Blue
Three Core - Brown, Black & Grey (Optional: Brown, Blue & Green/Yellow)
Four Core - Brown, Black, Grey & Blue (Optional: Brown, Black, Grey & Green/Yellow)
Five Core - Numbered Cores (Optional: Brown, Black, Grey, Blue & Green/Yellow)
Six Core and Above - Numbered Cores (Optional: Numbered + Green/Yellow)
MINIMUM BENDING RADIUS:
1.5sqmm - 16sqmm - 6x Overall diameter (circular cond.) 25sqmm and above - 8 x Overall Diameter (shaped cond.)
OPERATING TEMPERATURE: Maximum 90°C
STANDARDS:
BS5467: Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000V and 1900/3300V IEC60502: Power cables with extruded insulation and their accessories for rated voltages from 1kV to 30kV
CONDUCTOR: Plain Copper STRANDING: Class 2 INSULATION: XLPE
BEDDING: PVC ARMOUR: Steel Wire Armour OUTERSHEATH: PVC
OUTERSHEATH COLOUR: Grey
CORE IDENTIFICATION:
2 core: Blue and Brown
3 core: Black, Brown and Grey
4 core: Black, Brown, Grey and Blue
5 core: Black, Brown, Grey, Blue and Black
Optional: 3 core: Black, Brown & Blue
MINIMUM BENDING RADIUS: 15 x overall diameter
OPERATING TEMPERATURE:
Maximum 90°C Minimum bending 0°C / Service temperature: -20 to +90°C / Min laying temperature: -5°C
STANDARDS: HD 604 PART 4 SECTION D.
ELECTRICAL CHARACTERISTICS
CONDUCTOR: Plain Copper STRANDING: Class 1
INSULATION: XLPE BEDDING: PVC
ARMOUR: Steel Wire Braid OUTERSHEATH: PVC
OUTERSHEATH COLOUR: Grey RATED VOLTAGE: 0.6/1kV
CORE IDENTIFICATION:
2 core: Blue and Brown
3 core: Black, Brown and Grey
4 core: Black, Brown, Grey and Blue
5 core: Black, Brown, Grey, Blue and Black
Optional: 3 core - Black, Brown & Blue
MINIMUM BENDING RADIUS: 10 x overall diameter
OPERATING TEMPERATURE: Temperature: -20°C to +90°C / Min laying temperature: -5°C
STANDARDS: KEMA approved HD 604 Part 4 Section D
ELECTRICAL CHARACTERISTICS
CONDUCTOR: Plain Copper
STRANDING: Class 2
RATED VOLTAGE: 450/750v
MINIMUM BENDING RADIUS: Overall Bending Radius 6x
OPERATING TEMPERATURE: 90°C
STANDARDS: BS7211
CONDUCTOR: Plain Copper STRANDING: Class 2 INSULATION: XLPE
OUTERSHEATH: LSZH OUTERSHEATH COLOUR: Black, White, Blue, Red, Brown, Yellow
RATED VOLTAGE: 0.6/1kV
MINIMUM BENDING RADIUS:
Diameter up to 25mm: 4 x overall diameter Diameter over 25mm: 6 x overall diameter
OPERATING TEMPERATURE : Maximum 90°C Minimum flexing -15°C
STANDARDS: BS6724: Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000V and 1900/3300V, having low emission of smoke and corrosive gases when affected by fire BSEN50267-1Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Apparatus BSEN50267-2-1:Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures. Determination of the amount of halogen acid gas. Flame Propagation: Meets BS EN 60332-1-2:2004
CONDUCTOR: Plain Copper STRANDING: Class 2
INSULATION: XLPE OUTERSHEATH: PVC
OUTERSHEATH COLOUR: Black, Blue, Grey, Brown RATED VOLTAGE: 0.6/1kV
CORE IDENTIFICATION: Black ,Blue ,Grey ,Brown
MINIMUM BENDING RADIUS: 6 x Overall Diameter OPERATING TEMPERATURE: 90°C
STANDARDS: BS7889
ELECTRICAL CHARACTERISTICS
CONDUCTOR: Plain Copper
STRANDING: Class 1 and Class 2 INSULATION: PVC
OUTERSHEATH: PVC RATED VOLTAGE: 300/500V
MINIMUM BENDING RADIUS:
Diameter up to 10mm 3 x Overall diameter Diameter 10 – 25mm 4 x Overall diameter
OPERATING TEMPERATURE: Maximum 70°C, minimum bending 0°C
CONDUCTOR: Aluminium STRANDING: Class 1
INSULATION: XLPE OUTERSHEATH: PVC
OUTERSHEATH COLOUR: Black RATED VOLTAGE : 0.6/1kV
MINIMUM BENDING RADIUS: Overall Bending Radius 8x
OPERATING TEMPERATURE: 70°C
STANDARDS: BS 7870-3-11, EN 60228 Flame Retardant according to IEC/EN 60332-1-2
Batt Part No. Core Size Colour/Reference
16791 3 35 Black
ELECTRICAL CHARACTERISTICS
No. of Cores Nominal Cross Sectional Area mm2 Current Carrying Capacity AMPS (in Air) Currnet Carrying Capacity Amps (Clipped Direct) Current Carrying Capacity Amps (Enclosed in Conduit on a Wall)
1 25 127 119 105
1 35 158 147 128
3 25 97 90 84
3 35 120 112 103
CONDUCTORS
Nomincal Coross Sectional Area mm2 Maximum DC Resistance of Conductor at 20°C ohms/km Maximum DC Resistance of Concentric Conductor at 20°C ohms/km
25 1.2 1.3
35 0.868 0.91
DIMENSIONS
BATT Part No Cores Nominal cross sectional area of conductor Approx overall diameter Weight
16791 3 35 25 820
Electrical Equipment & Supplies